@@ -272,6 +272,42 @@
|
|
|
<config default="20" name="ToleranceAlarmRange" nameView="Tolerance Alarm Range" description="Tolerance Alarm Range" max="200" min="0" paramter="" tag="" unit="℃" type="Integer" />
|
|
|
<config default="60" name="ToleranceAlarmTime" nameView="Tolerance Alarm Time" description="Tolerance Alarm Time" max="60" min="0" paramter="" tag="" unit="second" type="Integer" />
|
|
|
</configs>
|
|
|
+ <configs name="InnerChiller" nameView="InnerChiller" >
|
|
|
+ <config default="false" name="EnableChiller" nameView="Enable Chiller" description="enable chiller or not" max="1" min="0" tag="" unit="" type="Bool" />
|
|
|
+ <config default="1" name="MFG" nameView="MFG" description="厂商, 1:SMC; 2, AIRSYS" max="10" min="0" paramter="" tag="" unit="" type="Integer" />
|
|
|
+ <config default="1" name="CommunicationType" nameView="Communication Type" description="0:Analogue; 1:RS232; 2:Ethernet" max="10" min="0" paramter="" tag="" unit="" type="Integer" />
|
|
|
+ <config default="COM45" name="Port" nameView="Port" description="serial port name of pump" max="" min="" paramter="" tag="" unit="" type="String" />
|
|
|
+ <config default="10" name="ChillerTemperatureOffset" nameView="Chiller Temperature Offset" description="" max="100" min="0" paramter="" tag="" unit="degree" type="Double" />
|
|
|
+ <config default="300" name="SetPointLimitMax" nameView="Chiller Set Point Limit Max" description="" max="500" min="0" paramter="" tag="" unit="degree" type="Double" />
|
|
|
+ <config default="0" name="SetPointLimitMin" nameView="Chiller Set Point Limit Min" description="" max="500" min="0" paramter="" tag="" unit="degree" type="Double" />
|
|
|
+ <config default="true" name="EnableToleranceAlarm" nameView="Enable Tolerance Alarm" description="Enable Tolerance Alarm" max="1" min="0" paramter="" tag="" unit="" type="Bool" />
|
|
|
+ <config default="20" name="ToleranceAlarmRange" nameView="Tolerance Alarm Range" description="Tolerance Alarm Range" max="200" min="0" paramter="" tag="" unit="℃" type="Integer" />
|
|
|
+ <config default="60" name="ToleranceAlarmTime" nameView="Tolerance Alarm Time" description="Tolerance Alarm Time" max="60" min="0" paramter="" tag="" unit="second" type="Integer" />
|
|
|
+ </configs>
|
|
|
+ <configs name="OuterChiller" nameView="OuterChiller" >
|
|
|
+ <config default="false" name="EnableChiller" nameView="Enable Chiller" description="enable chiller or not" max="1" min="0" tag="" unit="" type="Bool" />
|
|
|
+ <config default="1" name="MFG" nameView="MFG" description="厂商, 1:SMC; 2, AIRSYS" max="10" min="0" paramter="" tag="" unit="" type="Integer" />
|
|
|
+ <config default="1" name="CommunicationType" nameView="Communication Type" description="0:Analogue; 1:RS232; 2:Ethernet" max="10" min="0" paramter="" tag="" unit="" type="Integer" />
|
|
|
+ <config default="COM46" name="Port" nameView="Port" description="serial port name of pump" max="" min="" paramter="" tag="" unit="" type="String" />
|
|
|
+ <config default="10" name="ChillerTemperatureOffset" nameView="Chiller Temperature Offset" description="" max="100" min="0" paramter="" tag="" unit="degree" type="Double" />
|
|
|
+ <config default="300" name="SetPointLimitMax" nameView="Chiller Set Point Limit Max" description="" max="500" min="0" paramter="" tag="" unit="degree" type="Double" />
|
|
|
+ <config default="0" name="SetPointLimitMin" nameView="Chiller Set Point Limit Min" description="" max="500" min="0" paramter="" tag="" unit="degree" type="Double" />
|
|
|
+ <config default="true" name="EnableToleranceAlarm" nameView="Enable Tolerance Alarm" description="Enable Tolerance Alarm" max="1" min="0" paramter="" tag="" unit="" type="Bool" />
|
|
|
+ <config default="20" name="ToleranceAlarmRange" nameView="Tolerance Alarm Range" description="Tolerance Alarm Range" max="200" min="0" paramter="" tag="" unit="℃" type="Integer" />
|
|
|
+ <config default="60" name="ToleranceAlarmTime" nameView="Tolerance Alarm Time" description="Tolerance Alarm Time" max="60" min="0" paramter="" tag="" unit="second" type="Integer" />
|
|
|
+ </configs>
|
|
|
+ <configs name="TopChiller" nameView="TopChiller" >
|
|
|
+ <config default="false" name="EnableChiller" nameView="Enable Chiller" description="enable chiller or not" max="1" min="0" tag="" unit="" type="Bool" />
|
|
|
+ <config default="1" name="MFG" nameView="MFG" description="厂商, 1:SMC; 2, AIRSYS" max="10" min="0" paramter="" tag="" unit="" type="Integer" />
|
|
|
+ <config default="1" name="CommunicationType" nameView="Communication Type" description="0:Analogue; 1:RS232; 2:Ethernet" max="10" min="0" paramter="" tag="" unit="" type="Integer" />
|
|
|
+ <config default="COM47" name="Port" nameView="Port" description="serial port name of pump" max="" min="" paramter="" tag="" unit="" type="String" />
|
|
|
+ <config default="10" name="ChillerTemperatureOffset" nameView="Chiller Temperature Offset" description="" max="100" min="0" paramter="" tag="" unit="degree" type="Double" />
|
|
|
+ <config default="300" name="SetPointLimitMax" nameView="Chiller Set Point Limit Max" description="" max="500" min="0" paramter="" tag="" unit="degree" type="Double" />
|
|
|
+ <config default="0" name="SetPointLimitMin" nameView="Chiller Set Point Limit Min" description="" max="500" min="0" paramter="" tag="" unit="degree" type="Double" />
|
|
|
+ <config default="true" name="EnableToleranceAlarm" nameView="Enable Tolerance Alarm" description="Enable Tolerance Alarm" max="1" min="0" paramter="" tag="" unit="" type="Bool" />
|
|
|
+ <config default="20" name="ToleranceAlarmRange" nameView="Tolerance Alarm Range" description="Tolerance Alarm Range" max="200" min="0" paramter="" tag="" unit="℃" type="Integer" />
|
|
|
+ <config default="60" name="ToleranceAlarmTime" nameView="Tolerance Alarm Time" description="Tolerance Alarm Time" max="60" min="0" paramter="" tag="" unit="second" type="Integer" />
|
|
|
+ </configs>
|
|
|
<configs name="DryPump" nameView="Dry Pump" >
|
|
|
<config default="1" name="MFG" nameView="MFG" description="厂商, 1:Sky; 2:Edwards" max="10" min="0" paramter="" tag="" unit="" type="Integer" />
|
|
|
<config default="1" name="CommunicationType" nameView="Communication Type" description="0:Analogue; 1:RS232; 2:Ethernet" max="10" min="0" paramter="" tag="" unit="" type="Integer" />
|
|
@@ -738,6 +774,42 @@
|
|
|
<config default="20" name="ToleranceAlarmRange" nameView="Tolerance Alarm Range" description="Tolerance Alarm Range" max="200" min="0" paramter="" tag="" unit="℃" type="Integer" />
|
|
|
<config default="60" name="ToleranceAlarmTime" nameView="Tolerance Alarm Time" description="Tolerance Alarm Time" max="60" min="0" paramter="" tag="" unit="second" type="Integer" />
|
|
|
</configs>
|
|
|
+ <configs name="InnerChiller" nameView="InnerChiller" >
|
|
|
+ <config default="true" name="EnableChiller" nameView="Enable Chiller" description="enable chiller or not" max="1" min="0" tag="" unit="" type="Bool" />
|
|
|
+ <config default="1" name="MFG" nameView="MFG" description="厂商, 1:SMC; 2, AIRSYS" max="10" min="0" paramter="" tag="" unit="" type="Integer" />
|
|
|
+ <config default="1" name="CommunicationType" nameView="Communication Type" description="0:Analogue; 1:RS232; 2:Ethernet" max="10" min="0" paramter="" tag="" unit="" type="Integer" />
|
|
|
+ <config default="COM45" name="Port" nameView="Port" description="serial port name of pump" max="" min="" paramter="" tag="" unit="" type="String" />
|
|
|
+ <config default="10" name="ChillerTemperatureOffset" nameView="Chiller Temperature Offset" description="" max="100" min="0" paramter="" tag="" unit="degree" type="Double" />
|
|
|
+ <config default="300" name="SetPointLimitMax" nameView="Chiller Set Point Limit Max" description="" max="500" min="0" paramter="" tag="" unit="degree" type="Double" />
|
|
|
+ <config default="0" name="SetPointLimitMin" nameView="Chiller Set Point Limit Min" description="" max="500" min="0" paramter="" tag="" unit="degree" type="Double" />
|
|
|
+ <config default="true" name="EnableToleranceAlarm" nameView="Enable Tolerance Alarm" description="Enable Tolerance Alarm" max="1" min="0" paramter="" tag="" unit="" type="Bool" />
|
|
|
+ <config default="20" name="ToleranceAlarmRange" nameView="Tolerance Alarm Range" description="Tolerance Alarm Range" max="200" min="0" paramter="" tag="" unit="℃" type="Integer" />
|
|
|
+ <config default="60" name="ToleranceAlarmTime" nameView="Tolerance Alarm Time" description="Tolerance Alarm Time" max="60" min="0" paramter="" tag="" unit="second" type="Integer" />
|
|
|
+ </configs>
|
|
|
+ <configs name="OuterChiller" nameView="OuterChiller" >
|
|
|
+ <config default="true" name="EnableChiller" nameView="Enable Chiller" description="enable chiller or not" max="1" min="0" tag="" unit="" type="Bool" />
|
|
|
+ <config default="1" name="MFG" nameView="MFG" description="厂商, 1:SMC; 2, AIRSYS" max="10" min="0" paramter="" tag="" unit="" type="Integer" />
|
|
|
+ <config default="1" name="CommunicationType" nameView="Communication Type" description="0:Analogue; 1:RS232; 2:Ethernet" max="10" min="0" paramter="" tag="" unit="" type="Integer" />
|
|
|
+ <config default="COM46" name="Port" nameView="Port" description="serial port name of pump" max="" min="" paramter="" tag="" unit="" type="String" />
|
|
|
+ <config default="10" name="ChillerTemperatureOffset" nameView="Chiller Temperature Offset" description="" max="100" min="0" paramter="" tag="" unit="degree" type="Double" />
|
|
|
+ <config default="300" name="SetPointLimitMax" nameView="Chiller Set Point Limit Max" description="" max="500" min="0" paramter="" tag="" unit="degree" type="Double" />
|
|
|
+ <config default="0" name="SetPointLimitMin" nameView="Chiller Set Point Limit Min" description="" max="500" min="0" paramter="" tag="" unit="degree" type="Double" />
|
|
|
+ <config default="true" name="EnableToleranceAlarm" nameView="Enable Tolerance Alarm" description="Enable Tolerance Alarm" max="1" min="0" paramter="" tag="" unit="" type="Bool" />
|
|
|
+ <config default="20" name="ToleranceAlarmRange" nameView="Tolerance Alarm Range" description="Tolerance Alarm Range" max="200" min="0" paramter="" tag="" unit="℃" type="Integer" />
|
|
|
+ <config default="60" name="ToleranceAlarmTime" nameView="Tolerance Alarm Time" description="Tolerance Alarm Time" max="60" min="0" paramter="" tag="" unit="second" type="Integer" />
|
|
|
+ </configs>
|
|
|
+ <configs name="TopChiller" nameView="TopChiller" >
|
|
|
+ <config default="true" name="EnableChiller" nameView="Enable Chiller" description="enable chiller or not" max="1" min="0" tag="" unit="" type="Bool" />
|
|
|
+ <config default="1" name="MFG" nameView="MFG" description="厂商, 1:SMC; 2, AIRSYS" max="10" min="0" paramter="" tag="" unit="" type="Integer" />
|
|
|
+ <config default="1" name="CommunicationType" nameView="Communication Type" description="0:Analogue; 1:RS232; 2:Ethernet" max="10" min="0" paramter="" tag="" unit="" type="Integer" />
|
|
|
+ <config default="COM47" name="Port" nameView="Port" description="serial port name of pump" max="" min="" paramter="" tag="" unit="" type="String" />
|
|
|
+ <config default="10" name="ChillerTemperatureOffset" nameView="Chiller Temperature Offset" description="" max="100" min="0" paramter="" tag="" unit="degree" type="Double" />
|
|
|
+ <config default="300" name="SetPointLimitMax" nameView="Chiller Set Point Limit Max" description="" max="500" min="0" paramter="" tag="" unit="degree" type="Double" />
|
|
|
+ <config default="0" name="SetPointLimitMin" nameView="Chiller Set Point Limit Min" description="" max="500" min="0" paramter="" tag="" unit="degree" type="Double" />
|
|
|
+ <config default="true" name="EnableToleranceAlarm" nameView="Enable Tolerance Alarm" description="Enable Tolerance Alarm" max="1" min="0" paramter="" tag="" unit="" type="Bool" />
|
|
|
+ <config default="20" name="ToleranceAlarmRange" nameView="Tolerance Alarm Range" description="Tolerance Alarm Range" max="200" min="0" paramter="" tag="" unit="℃" type="Integer" />
|
|
|
+ <config default="60" name="ToleranceAlarmTime" nameView="Tolerance Alarm Time" description="Tolerance Alarm Time" max="60" min="0" paramter="" tag="" unit="second" type="Integer" />
|
|
|
+ </configs>
|
|
|
<configs name="DryPump" nameView="Dry Pump" >
|
|
|
<config default="1" name="MFG" nameView="MFG" description="厂商, 1:Sky; 2:Edwards" max="10" min="0" paramter="" tag="" unit="" type="Integer" />
|
|
|
<config default="1" name="CommunicationType" nameView="Communication Type" description="0:Analogue; 1:RS232; 2:Ethernet" max="10" min="0" paramter="" tag="" unit="" type="Integer" />
|
|
@@ -1188,6 +1260,42 @@
|
|
|
<config default="20" name="ToleranceAlarmRange" nameView="Tolerance Alarm Range" description="Tolerance Alarm Range" max="200" min="0" paramter="" tag="" unit="℃" type="Integer" />
|
|
|
<config default="60" name="ToleranceAlarmTime" nameView="Tolerance Alarm Time" description="Tolerance Alarm Time" max="60" min="0" paramter="" tag="" unit="second" type="Integer" />
|
|
|
</configs>
|
|
|
+ <configs name="InnerChiller" nameView="InnerChiller" >
|
|
|
+ <config default="false" name="EnableChiller" nameView="Enable Chiller" description="enable chiller or not" max="1" min="0" tag="" unit="" type="Bool" />
|
|
|
+ <config default="1" name="MFG" nameView="MFG" description="厂商, 1:SMC; 2, AIRSYS" max="10" min="0" paramter="" tag="" unit="" type="Integer" />
|
|
|
+ <config default="1" name="CommunicationType" nameView="Communication Type" description="0:Analogue; 1:RS232; 2:Ethernet" max="10" min="0" paramter="" tag="" unit="" type="Integer" />
|
|
|
+ <config default="COM45" name="Port" nameView="Port" description="serial port name of pump" max="" min="" paramter="" tag="" unit="" type="String" />
|
|
|
+ <config default="10" name="ChillerTemperatureOffset" nameView="Chiller Temperature Offset" description="" max="100" min="0" paramter="" tag="" unit="degree" type="Double" />
|
|
|
+ <config default="300" name="SetPointLimitMax" nameView="Chiller Set Point Limit Max" description="" max="500" min="0" paramter="" tag="" unit="degree" type="Double" />
|
|
|
+ <config default="0" name="SetPointLimitMin" nameView="Chiller Set Point Limit Min" description="" max="500" min="0" paramter="" tag="" unit="degree" type="Double" />
|
|
|
+ <config default="true" name="EnableToleranceAlarm" nameView="Enable Tolerance Alarm" description="Enable Tolerance Alarm" max="1" min="0" paramter="" tag="" unit="" type="Bool" />
|
|
|
+ <config default="20" name="ToleranceAlarmRange" nameView="Tolerance Alarm Range" description="Tolerance Alarm Range" max="200" min="0" paramter="" tag="" unit="℃" type="Integer" />
|
|
|
+ <config default="60" name="ToleranceAlarmTime" nameView="Tolerance Alarm Time" description="Tolerance Alarm Time" max="60" min="0" paramter="" tag="" unit="second" type="Integer" />
|
|
|
+ </configs>
|
|
|
+ <configs name="OuterChiller" nameView="OuterChiller" >
|
|
|
+ <config default="false" name="EnableChiller" nameView="Enable Chiller" description="enable chiller or not" max="1" min="0" tag="" unit="" type="Bool" />
|
|
|
+ <config default="1" name="MFG" nameView="MFG" description="厂商, 1:SMC; 2, AIRSYS" max="10" min="0" paramter="" tag="" unit="" type="Integer" />
|
|
|
+ <config default="1" name="CommunicationType" nameView="Communication Type" description="0:Analogue; 1:RS232; 2:Ethernet" max="10" min="0" paramter="" tag="" unit="" type="Integer" />
|
|
|
+ <config default="COM46" name="Port" nameView="Port" description="serial port name of pump" max="" min="" paramter="" tag="" unit="" type="String" />
|
|
|
+ <config default="10" name="ChillerTemperatureOffset" nameView="Chiller Temperature Offset" description="" max="100" min="0" paramter="" tag="" unit="degree" type="Double" />
|
|
|
+ <config default="300" name="SetPointLimitMax" nameView="Chiller Set Point Limit Max" description="" max="500" min="0" paramter="" tag="" unit="degree" type="Double" />
|
|
|
+ <config default="0" name="SetPointLimitMin" nameView="Chiller Set Point Limit Min" description="" max="500" min="0" paramter="" tag="" unit="degree" type="Double" />
|
|
|
+ <config default="true" name="EnableToleranceAlarm" nameView="Enable Tolerance Alarm" description="Enable Tolerance Alarm" max="1" min="0" paramter="" tag="" unit="" type="Bool" />
|
|
|
+ <config default="20" name="ToleranceAlarmRange" nameView="Tolerance Alarm Range" description="Tolerance Alarm Range" max="200" min="0" paramter="" tag="" unit="℃" type="Integer" />
|
|
|
+ <config default="60" name="ToleranceAlarmTime" nameView="Tolerance Alarm Time" description="Tolerance Alarm Time" max="60" min="0" paramter="" tag="" unit="second" type="Integer" />
|
|
|
+ </configs>
|
|
|
+ <configs name="TopChiller" nameView="TopChiller" >
|
|
|
+ <config default="false" name="EnableChiller" nameView="Enable Chiller" description="enable chiller or not" max="1" min="0" tag="" unit="" type="Bool" />
|
|
|
+ <config default="1" name="MFG" nameView="MFG" description="厂商, 1:SMC; 2, AIRSYS" max="10" min="0" paramter="" tag="" unit="" type="Integer" />
|
|
|
+ <config default="1" name="CommunicationType" nameView="Communication Type" description="0:Analogue; 1:RS232; 2:Ethernet" max="10" min="0" paramter="" tag="" unit="" type="Integer" />
|
|
|
+ <config default="COM47" name="Port" nameView="Port" description="serial port name of pump" max="" min="" paramter="" tag="" unit="" type="String" />
|
|
|
+ <config default="10" name="ChillerTemperatureOffset" nameView="Chiller Temperature Offset" description="" max="100" min="0" paramter="" tag="" unit="degree" type="Double" />
|
|
|
+ <config default="300" name="SetPointLimitMax" nameView="Chiller Set Point Limit Max" description="" max="500" min="0" paramter="" tag="" unit="degree" type="Double" />
|
|
|
+ <config default="0" name="SetPointLimitMin" nameView="Chiller Set Point Limit Min" description="" max="500" min="0" paramter="" tag="" unit="degree" type="Double" />
|
|
|
+ <config default="true" name="EnableToleranceAlarm" nameView="Enable Tolerance Alarm" description="Enable Tolerance Alarm" max="1" min="0" paramter="" tag="" unit="" type="Bool" />
|
|
|
+ <config default="20" name="ToleranceAlarmRange" nameView="Tolerance Alarm Range" description="Tolerance Alarm Range" max="200" min="0" paramter="" tag="" unit="℃" type="Integer" />
|
|
|
+ <config default="60" name="ToleranceAlarmTime" nameView="Tolerance Alarm Time" description="Tolerance Alarm Time" max="60" min="0" paramter="" tag="" unit="second" type="Integer" />
|
|
|
+ </configs>
|
|
|
<configs name="DryPump" nameView="Dry Pump" >
|
|
|
<config default="1" name="MFG" nameView="MFG" description="厂商, 1:Sky; 2:Edwards" max="10" min="0" paramter="" tag="" unit="" type="Integer" />
|
|
|
<config default="1" name="CommunicationType" nameView="Communication Type" description="0:Analogue; 1:RS232; 2:Ethernet" max="10" min="0" paramter="" tag="" unit="" type="Integer" />
|
|
@@ -1573,7 +1681,7 @@
|
|
|
</configs>
|
|
|
|
|
|
<!--PMD-->
|
|
|
- <configs name="PMD" nameView="PMD" >
|
|
|
+ <configs name="PMD" nameView="PMD" >
|
|
|
<config default="2" name="ChamberType" nameView="Chamber Type" description="0=>Venus,1=>Kepler2300,2=>Kepler2200A,3=>Kepler2200B" max="3" min="0" paramter="" tag="" unit="" type="Integer" visible="false"/>
|
|
|
<config default="100" name="TurboN2FlowSetPoint" nameView="TurboN2SetPoint" description="" max="200" min="0" paramter="" tag="" unit="mtorr" type="Double" />
|
|
|
<config default="120" name="PrepareTransferTimeout" nameView="Prepare Transfer Timeout" description="prepare transfer time out" max="99999" min="1" paramter="" tag="" unit="s" type="Integer" />
|
|
@@ -1638,6 +1746,42 @@
|
|
|
<config default="20" name="ToleranceAlarmRange" nameView="Tolerance Alarm Range" description="Tolerance Alarm Range" max="200" min="0" paramter="" tag="" unit="℃" type="Integer" />
|
|
|
<config default="60" name="ToleranceAlarmTime" nameView="Tolerance Alarm Time" description="Tolerance Alarm Time" max="60" min="0" paramter="" tag="" unit="second" type="Integer" />
|
|
|
</configs>
|
|
|
+ <configs name="InnerChiller" nameView="InnerChiller" >
|
|
|
+ <config default="false" name="EnableChiller" nameView="Enable Chiller" description="enable chiller or not" max="1" min="0" tag="" unit="" type="Bool" />
|
|
|
+ <config default="1" name="MFG" nameView="MFG" description="厂商, 1:SMC; 2, AIRSYS" max="10" min="0" paramter="" tag="" unit="" type="Integer" />
|
|
|
+ <config default="1" name="CommunicationType" nameView="Communication Type" description="0:Analogue; 1:RS232; 2:Ethernet" max="10" min="0" paramter="" tag="" unit="" type="Integer" />
|
|
|
+ <config default="COM45" name="Port" nameView="Port" description="serial port name of pump" max="" min="" paramter="" tag="" unit="" type="String" />
|
|
|
+ <config default="10" name="ChillerTemperatureOffset" nameView="Chiller Temperature Offset" description="" max="100" min="0" paramter="" tag="" unit="degree" type="Double" />
|
|
|
+ <config default="300" name="SetPointLimitMax" nameView="Chiller Set Point Limit Max" description="" max="500" min="0" paramter="" tag="" unit="degree" type="Double" />
|
|
|
+ <config default="0" name="SetPointLimitMin" nameView="Chiller Set Point Limit Min" description="" max="500" min="0" paramter="" tag="" unit="degree" type="Double" />
|
|
|
+ <config default="true" name="EnableToleranceAlarm" nameView="Enable Tolerance Alarm" description="Enable Tolerance Alarm" max="1" min="0" paramter="" tag="" unit="" type="Bool" />
|
|
|
+ <config default="20" name="ToleranceAlarmRange" nameView="Tolerance Alarm Range" description="Tolerance Alarm Range" max="200" min="0" paramter="" tag="" unit="℃" type="Integer" />
|
|
|
+ <config default="60" name="ToleranceAlarmTime" nameView="Tolerance Alarm Time" description="Tolerance Alarm Time" max="60" min="0" paramter="" tag="" unit="second" type="Integer" />
|
|
|
+ </configs>
|
|
|
+ <configs name="OuterChiller" nameView="OuterChiller" >
|
|
|
+ <config default="false" name="EnableChiller" nameView="Enable Chiller" description="enable chiller or not" max="1" min="0" tag="" unit="" type="Bool" />
|
|
|
+ <config default="1" name="MFG" nameView="MFG" description="厂商, 1:SMC; 2, AIRSYS" max="10" min="0" paramter="" tag="" unit="" type="Integer" />
|
|
|
+ <config default="1" name="CommunicationType" nameView="Communication Type" description="0:Analogue; 1:RS232; 2:Ethernet" max="10" min="0" paramter="" tag="" unit="" type="Integer" />
|
|
|
+ <config default="COM46" name="Port" nameView="Port" description="serial port name of pump" max="" min="" paramter="" tag="" unit="" type="String" />
|
|
|
+ <config default="10" name="ChillerTemperatureOffset" nameView="Chiller Temperature Offset" description="" max="100" min="0" paramter="" tag="" unit="degree" type="Double" />
|
|
|
+ <config default="300" name="SetPointLimitMax" nameView="Chiller Set Point Limit Max" description="" max="500" min="0" paramter="" tag="" unit="degree" type="Double" />
|
|
|
+ <config default="0" name="SetPointLimitMin" nameView="Chiller Set Point Limit Min" description="" max="500" min="0" paramter="" tag="" unit="degree" type="Double" />
|
|
|
+ <config default="true" name="EnableToleranceAlarm" nameView="Enable Tolerance Alarm" description="Enable Tolerance Alarm" max="1" min="0" paramter="" tag="" unit="" type="Bool" />
|
|
|
+ <config default="20" name="ToleranceAlarmRange" nameView="Tolerance Alarm Range" description="Tolerance Alarm Range" max="200" min="0" paramter="" tag="" unit="℃" type="Integer" />
|
|
|
+ <config default="60" name="ToleranceAlarmTime" nameView="Tolerance Alarm Time" description="Tolerance Alarm Time" max="60" min="0" paramter="" tag="" unit="second" type="Integer" />
|
|
|
+ </configs>
|
|
|
+ <configs name="TopChiller" nameView="TopChiller" >
|
|
|
+ <config default="false" name="EnableChiller" nameView="Enable Chiller" description="enable chiller or not" max="1" min="0" tag="" unit="" type="Bool" />
|
|
|
+ <config default="1" name="MFG" nameView="MFG" description="厂商, 1:SMC; 2, AIRSYS" max="10" min="0" paramter="" tag="" unit="" type="Integer" />
|
|
|
+ <config default="1" name="CommunicationType" nameView="Communication Type" description="0:Analogue; 1:RS232; 2:Ethernet" max="10" min="0" paramter="" tag="" unit="" type="Integer" />
|
|
|
+ <config default="COM47" name="Port" nameView="Port" description="serial port name of pump" max="" min="" paramter="" tag="" unit="" type="String" />
|
|
|
+ <config default="10" name="ChillerTemperatureOffset" nameView="Chiller Temperature Offset" description="" max="100" min="0" paramter="" tag="" unit="degree" type="Double" />
|
|
|
+ <config default="300" name="SetPointLimitMax" nameView="Chiller Set Point Limit Max" description="" max="500" min="0" paramter="" tag="" unit="degree" type="Double" />
|
|
|
+ <config default="0" name="SetPointLimitMin" nameView="Chiller Set Point Limit Min" description="" max="500" min="0" paramter="" tag="" unit="degree" type="Double" />
|
|
|
+ <config default="true" name="EnableToleranceAlarm" nameView="Enable Tolerance Alarm" description="Enable Tolerance Alarm" max="1" min="0" paramter="" tag="" unit="" type="Bool" />
|
|
|
+ <config default="20" name="ToleranceAlarmRange" nameView="Tolerance Alarm Range" description="Tolerance Alarm Range" max="200" min="0" paramter="" tag="" unit="℃" type="Integer" />
|
|
|
+ <config default="60" name="ToleranceAlarmTime" nameView="Tolerance Alarm Time" description="Tolerance Alarm Time" max="60" min="0" paramter="" tag="" unit="second" type="Integer" />
|
|
|
+ </configs>
|
|
|
<configs name="DryPump" nameView="Dry Pump" >
|
|
|
<config default="1" name="MFG" nameView="MFG" description="厂商, 1:Sky; 2:Edwards" max="10" min="0" paramter="" tag="" unit="" type="Integer" />
|
|
|
<config default="1" name="CommunicationType" nameView="Communication Type" description="0:Analogue; 1:RS232; 2:Ethernet" max="10" min="0" paramter="" tag="" unit="" type="Integer" />
|