123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145 |
- using Aitex.Core.RT.Routine;
- using Aitex.Core.RT.SCCore;
- using System;
- using System.Collections.Generic;
- using System.Linq;
- using System.Text;
- using System.Threading.Tasks;
- using Venus_Core;
- using Venus_RT.Devices;
- namespace Venus_RT.Modules.PMs
- {
- class VenusVentRoutine : PMRoutineBase, IRoutine
- {
- private enum VentStep
- {
- vISODelay,
- vClosePendulumValve,
- vCloseTurboPurge,
- vCloseTurboPumping,
- vClosePVValves,
- vDelayForPendulumValve,
- vOpenVentValves,
- vDelay_2,
- vCloseVentValves,
- }
- //private int _ventTime;
- private double _ventTimeDelay = 1;
- private int _checkATMTimeout = 90;
- public bool VentingFlag => _ventingflag;
- private bool _ventingflag = false;
- public VenusVentRoutine(JetPMBase chamber) : base(chamber)
- {
- Name = "PM Vent";
- }
- public RState Start(params object[] objs)
- {
- if (CheckLid() &&
- CheckSlitDoor() &&
- CheckCDA() &&
- CheckATM())
- {
- Reset();
- _checkATMTimeout = SC.GetValue<int>($"{Module}.CheckATMTimeout");
- _ventTimeDelay = SC.GetValue<double>($"{Module}.OverVentTime");
- if (Runner.Start(Module, Name) == RState.Running)
- {
- _ventingflag = true;
- return RState.Running;
- }
- else
- {
- _ventingflag = false;
- return RState.Failed;
- }
- }
- return RState.Failed;
- }
- public RState Monitor()
- {
- Runner.Delay(VentStep.vISODelay, _delay_2s)
- .Run(VentStep.vClosePendulumValve, PendulumValveClose, () => { return !_chamber.PendulumValveIsOpen(); })
- .Delay(VentStep.vDelayForPendulumValve, 500)
- .Run(VentStep.vCloseTurboPurge, CloseTurboPurge, _delay_3s)
- .Run(VentStep.vCloseTurboPumping, CloseTurboPumping, _delay_3s)
- .Run(VentStep.vClosePVValves, ClosePVValves, _delay_3s)
- .Run(VentStep.vOpenVentValves, OpenValve, () => { return _chamber.IsATM; }, _checkATMTimeout * 1000)
- .Delay(VentStep.vDelay_2, (int)_ventTimeDelay)
- .End(VentStep.vCloseVentValves, CloseVentGasFinalValves, _delay_2s);
- _ventingflag = Runner.Status == RState.Running;
- return Runner.Status;
- }
- private bool CloseTurboPumping()
- {
- _chamber.OpenValve(ValveType.TurboPumpPumping, false);
- return true;
- }
- private bool CloseTurboPurge()
- {
- _chamber.OpenValve(ValveType.TurboPumpPurge, false);
- return true;
- }
- private bool PendulumValveClose()
- {
- _chamber.TurnPendulumValve(false);
- return true;
- }
- private bool ClosePVValves()
- {
- _chamber.OpenValve(ValveType.Guage, false);
- if (_chamber.PendulumValveIsOpen())
- {
- return _chamber.TurnPendulumValve(false);
- }
- _chamber.OpenValve(ValveType.TurboPumpPumping, false);
- _chamber.OpenValve(ValveType.TurboPumpPurge, false);
- _chamber.OpenValve(ValveType.FastPump, false);
- _chamber.OpenValve(ValveType.SoftPump, false);
- return true;
- }
- private bool OpenValve()
- {
- _chamber.OpenValve(ValveType.PVN22, true);
- _chamber.OpenValve(ValveType.N2, true);
- _chamber.OpenValve(ValveType.GasFinal, true);
- return true;
- }
- private bool CloseVentGasFinalValves()
- {
- if (_chamber.ChamberType == JetChamber.VenusSE || _chamber.ChamberType == JetChamber.VenusDE)
- {
- _chamber.OpenValve(ValveType.PVN22, false);
- }
- _chamber.OpenValve(ValveType.GasFinal, false);
- _chamber.OpenValve(ValveType.N2, false);
- return true;
- }
- public void Abort()
- {
- CloseAllValves();
- }
- }
- }
|