| 123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182183184185186187188189190191192193194195196197198199200201202203204205206207208209210211212213214215216217218219220221222223224225226227228229230231232233234235236237238239240241242243244245246247248249250251252253254255256257258259260261262263264265266267268269270271272273274275276277278279280281282283284285286 | 
							- using System;
 
- using System.Xml;
 
- using Aitex.Core.Common.DeviceData;
 
- using Aitex.Core.RT.DataCenter;
 
- using Aitex.Core.RT.Event;
 
- using Aitex.Core.RT.IOCore;
 
- using Aitex.Core.RT.Log;
 
- using Aitex.Core.Util;
 
- namespace Aitex.Core.RT.Device.Unit
 
- {
 
-     public class IoThrottleValve : BaseDevice, IDevice
 
-     {
 
-         public struct Context
 
-         {
 
-             public string tvName;
 
-             public string aoPressureModeName;
 
-             public string aoPressureSetPointName;
 
-             public string aoPositionSetPointName;
 
-             public string aiPressureFeedbackName;
 
-             public string aiPositionFeedbackName;
 
-             public string aiStateName;
 
-         };
 
-         public PressureCtrlMode PressureMode
 
-         {
 
-             get
 
-             {
 
-                 if (_aoPressureMode == null)
 
-                     return PressureCtrlMode.TVPositionCtrl;
 
-                 return Math.Abs(_aoPressureMode.Value - 2) < 0.1 ? PressureCtrlMode.TVPositionCtrl : PressureCtrlMode.TVPressureCtrl;
 
-             }
 
-             set
 
-             {
 
-                 if (_aoPositionSetPoint == null || _aoPressureSetPoint == null || _aoPressureMode == null)
 
-                     return;
 
-                 float setpoint = value == PressureCtrlMode.TVPositionCtrl ? 2 : 1;
 
-                 if (Math.Abs(_aoPressureMode.Value - setpoint) > 0.01)
 
-                 {
 
-                     if (value == PressureCtrlMode.TVPositionCtrl)
 
-                     {
 
-                         _aoPositionSetPoint.Value = (short)PositionFeedback;
 
-                     }
 
-                     else
 
-                     {
 
-                         _aoPressureSetPoint.Value = (short)PressureFeedback;
 
-                     }
 
-                     _aoPressureMode.Value = (short)setpoint;
 
-                 }
 
-             }
 
-         }
 
-         public int State
 
-         {
 
-             get
 
-             {
 
-                 return _aiState == null ? 1 : (int)_aiState.Value;
 
-             }
 
-         }
 
-         [Subscription(AITThrottleValvePropertyName.TVPositionSetPoint)]
 
-         public float PositionSetpoint
 
-         {
 
-             get
 
-             {
 
-                 return _aoPositionSetPoint == null ? 0 : _aoPositionSetPoint.Value;
 
-             }
 
-             set
 
-             {
 
-                 if (_aoPositionSetPoint == null)
 
-                     return;
 
-                 _aoPositionSetPoint.Value = (short)value;
 
-             }
 
-         }
 
-         [Subscription(AITThrottleValvePropertyName.TVPosition)]
 
-         public float PositionFeedback
 
-         {
 
-             get
 
-             {
 
-                 return _aiPositionFeedback == null ? 0 : _aiPositionFeedback.Value;
 
-             }
 
-         }
 
-         [Subscription(AITThrottleValvePropertyName.TVPressureSetPoint)]
 
-         public float PressureSetpoint
 
-         {
 
-             get
 
-             {
 
-                 return _aoPressureSetPoint == null ? 0 : _aoPressureSetPoint.Value;
 
-             }
 
-             set
 
-             {
 
-                 if (_aoPressureSetPoint == null)
 
-                     return;
 
-                 _aoPressureSetPoint.Value = (short)value;
 
-             }
 
-         }
 
-         private AITThrottleValveData DeviceData
 
-         {
 
-             get
 
-             {
 
-                 AITThrottleValveData data = new AITThrottleValveData()
 
-                 {
 
-                     DeviceName = Name,
 
-                     DeviceSchematicId = DeviceID,
 
-                     DisplayName = Display,
 
-                     Mode = (int)PressureMode,
 
-                     PositionFeedback = PositionFeedback,
 
-                     PositionSetPoint = PositionSetpoint,
 
-                     PressureFeedback = PressureFeedback,
 
-                     PressureSetPoint = PressureSetpoint,
 
-                     State = State,
 
-                 };
 
-                 return data;
 
-             }
 
-         }
 
-         [Subscription(AITThrottleValvePropertyName.TVPressure)]
 
-         public float PressureFeedback
 
-         {
 
-             get
 
-             {
 
-                 return _aiPressureFeedback == null ? 0 : _aiPressureFeedback.Value;
 
-             }
 
-         }
 
-         public bool IsPumpMode
 
-         {
 
-             get; set;
 
-         }
 
-         public bool IsIndependent
 
-         {
 
-             get; set;
 
-         }
 
-         public bool IsOffline
 
-         {
 
-             get
 
-             {
 
-                 return _diOffline != null && _diOffline.RawData;
 
-             }
 
-         }
 
-         private DIAccessor _diOffline;
 
-         private AIAccessor _aiPressureFeedback = null;
 
-         private AIAccessor _aiPositionFeedback = null;
 
-         private AOAccessor _aoPressureSetPoint = null;
 
-         private AOAccessor _aoPositionSetPoint = null;
 
-         private AOAccessor _aoPressureMode = null;
 
-         private AIAccessor _aiState = null;
 
-         private R_TRIG _tvStatusAlmTrig = new R_TRIG();
 
-         private R_TRIG _trigOffline = new R_TRIG();
 
-         public IoThrottleValve(string module, XmlElement node, string ioModule = "")
 
-         {
 
-             base.Module = module;
 
-             base.Name = node.GetAttribute("id");
 
-             base.Display = node.GetAttribute("display");
 
-             base.DeviceID = node.GetAttribute("schematicId");
 
-             _aiPositionFeedback = ParseAiNode("aiPositionFeedback", node);
 
-             _aiPressureFeedback = ParseAiNode("aiPressureFeedback", node);
 
-             _aoPositionSetPoint = ParseAoNode("aoPositionSetPoint", node);
 
-             _aoPressureSetPoint = ParseAoNode("aoPressureSetPoint", node);
 
-             _aiState = ParseAiNode("aiState", node);
 
-             _aoPressureMode = ParseAoNode("aoPressureMode", node);
 
-             _diOffline = ParseDiNode("diOffline", node);
 
-         }
 
-         public bool Initialize()
 
-         {
 
-             DATA.Subscribe(string.Format("Device.{0}.{1}", Module, Name), () => DeviceData);
 
-             DATA.Subscribe($"{Module}.{Name}.DeviceData", () => DeviceData);
 
-             PressureMode = PressureCtrlMode.TVPressureCtrl;
 
-             DEVICE.Register(String.Format("{0}.{1}", Name, AITThrottleValveOperation.SetMode), (out string reason, int time, object[] param) =>
 
-             {
 
-                 PressureMode = (PressureCtrlMode)Enum.Parse(typeof(PressureCtrlMode), (string)param[0], true);
 
-                 reason = string.Format("Throttle valve set to {0} mode", PressureMode);
 
-                 return true;
 
-             });
 
-             DEVICE.Register(String.Format("{0}.{1}", Name, AITThrottleValveOperation.SetPosition), (out string reason, int time, object[] param) =>
 
-             {
 
-                 double target = Convert.ToDouble((string)param[0]);
 
-                 if (PressureMode != PressureCtrlMode.TVPositionCtrl)
 
-                 {
 
-                     reason = "Throttle valve in pressure mode, can not set position";
 
-                     return false;
 
-                 }
 
-                 PositionSetpoint = (float)target;
 
-                 reason = string.Format("position set to {0}%", target.ToString("F1"));
 
-                 return true;
 
-             });
 
-             DEVICE.Register(String.Format("{0}.{1}", Name, AITThrottleValveOperation.SetPressure), (out string reason, int time, object[] param) =>
 
-             {
 
-                 if (PressureMode == PressureCtrlMode.TVPositionCtrl)
 
-                 {
 
-                     reason = "Throttle valve is in positon conrol mode, can not set pressure";
 
-                     return false;
 
-                 }
 
-                 double target = Convert.ToDouble((string)param[0]);
 
-                 PressureSetpoint = (float)target;
 
-                 reason = string.Format("pressure set {0} mTorr", target);
 
-                 return true;
 
-             });
 
-             return true;
 
-         }
 
-         public void Terminate()
 
-         {
 
-         }
 
-         public void Monitor()
 
-         {
 
-             try
 
-             {
 
-                 _tvStatusAlmTrig.CLK = State != 1;
 
-                 if (_tvStatusAlmTrig.Q)
 
-                 {
 
-                     EV.PostMessage(Module, EventEnum.ThrottleValveAbnormal, Module);
 
-                 }
 
-                 _trigOffline.CLK = IsOffline;
 
-                 if (_trigOffline.Q)
 
-                 {
 
-                     EV.PostMessage(Module, EventEnum.DefaultAlarm, "Throttle Valve Offline");
 
-                 }
 
-             }
 
-             catch (Exception ex)
 
-             {
 
-                 LOG.Write(ex);
 
-             }
 
-         }
 
-  
 
-         public void Reset()
 
-         {
 
-             _tvStatusAlmTrig.RST = true;
 
-             _trigOffline.RST = true;
 
-         }
 
-         public void SetPositionMode(int position)
 
-         {
 
-             PressureMode = PressureCtrlMode.TVPositionCtrl;
 
-             PositionSetpoint = (float)position;
 
-         }
 
-     }
 
- }
 
 
  |