| 123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166 | 
							- using System;
 
- using System.Xml;
 
- using Aitex.Core.Common.DeviceData;
 
- using Aitex.Core.RT.DataCenter;
 
- using Aitex.Core.RT.Device;
 
- using Aitex.Core.RT.Event;
 
- using Aitex.Core.RT.IOCore;
 
- using Aitex.Core.RT.Log;
 
- using Aitex.Core.RT.OperationCenter;
 
- using Aitex.Core.Util;
 
- using MECF.Framework.Common.Event;
 
- using MECF.Framework.RT.EquipmentLibrary.HardwareUnits.Pumps;
 
- namespace FurnaceRT.Equipments.Systems
 
- {
 
-     public class IoPump3 : BaseDevice, IDevice 
 
-     {
 
-         
 
-        
 
-  
 
-         private DIAccessor _diPowerOn;
 
-         private DOAccessor _doPowerOn;
 
-         public IoPump3(string module, XmlElement node, string ioModule = "")
 
-         {
 
-             var attrModule = node.GetAttribute("module");
 
-             base.Module = string.IsNullOrEmpty(attrModule) ? module : attrModule;
 
-             base.Name = node.GetAttribute("id");
 
-             base.Display = node.GetAttribute("display");
 
-             base.DeviceID = node.GetAttribute("schematicId");
 
-            
 
-             _diPowerOn = ParseDiNode("diPowerOn", node, ioModule);
 
-            
 
-             _doPowerOn = ParseDoNode("doPowerOn", node, ioModule);
 
-         }
 
-         public bool Initialize()
 
-         {
 
-             DATA.Subscribe($"{Module}.{Name}.IsPumpRunning", () => _diPowerOn.Value);
 
-             OP.Subscribe($"{Module}.{Name}.{AITPumpOperation.SetOnOff}" , SetPumpOnOff);
 
-             OP.Subscribe($"{Module}.{Name}.{AITPumpOperation.PumpOn}", SetPumpOn);
 
-             OP.Subscribe($"{Module}.{Name}.{AITPumpOperation.PumpOff}", SetPumpOff);
 
-           
 
-             return true;
 
-         }
 
-         private bool SetPumpOn(out string reason, int time, object[] param)
 
-         {
 
-             return SetPump(out reason, time, true);
 
-         }
 
-         private bool SetPumpOff(out string reason, int time, object[] param)
 
-         {
 
-             return SetPump(out reason, time, false);
 
-         }
 
-         private bool SetPumpOnOff(out string reason, int time, object[] param)
 
-         {
 
-             return SetPump(out reason, time, Convert.ToBoolean((string)param[0]));
 
-         }
 
-         public bool SetPump(out string reason, int time, bool isOn)
 
-         {
 
-             reason = "";
 
-             if (isOn)
 
-             {
 
-                
 
-             }
 
-             _doPowerOn.Value = isOn;
 
-             return true;
 
-         }
 
-         public bool SetMainPowerOnOff(bool isOn, out string reason)
 
-         {
 
-             reason = string.Empty;
 
-             return true;
 
-         }
 
-         public void Terminate()
 
-         {
 
-         }
 
-  
 
-         public void Monitor()
 
-         {
 
-             try
 
-             {
 
-                 //_trigWarning.CLK = IsWarning;
 
-                 //if (_trigWarning.Q)
 
-                 //{
 
-                 //    PumpWarning.Set();
 
-                 //}
 
-                 //_trigError.CLK = IsError;
 
-                 //if (_trigError.Q)
 
-                 //{
 
-                 //    PumpError.Set();
 
-                 //    if (_doPowerOn != null && _doPowerOn.Value)
 
-                 //    {
 
-                 //        _doPowerOn.Value = false;
 
-                 //        EV.PostInfoLog(Module, $"set {Name} power off");
 
-                 //    }
 
-                 //    if (_doStart != null && _doStart.Value)
 
-                 //    {
 
-                 //        _doStart.Value = false;
 
-                 //        EV.PostInfoLog(Module, $"set {Name} off");
 
-                 //    }
 
-                 //}
 
-                 //_trigOverload.CLK = IsPumpOverloadAlarm;
 
-                 //if (_trigOverload.Q)
 
-                 //{
 
-                 //    PumpOverload.Set();
 
-                 //    if (_doPowerOn != null && _doPowerOn.Value)
 
-                 //    {
 
-                 //        _doPowerOn.Value = false;
 
-                 //        EV.PostInfoLog(Module, $"set {Name} power off");
 
-                 //    }
 
-                 //    if (_doStart != null && _doStart.Value)
 
-                 //    {
 
-                 //        _doStart.Value = false;
 
-                 //        EV.PostInfoLog(Module, $"set {Name} off");
 
-                 //    }
 
-                 //}
 
-                 //_trigN2OK.CLK = !IsN2OK;
 
-                 //if (_trigN2OK.Q)
 
-                 //{
 
-                 //    PumpN2NotOK.Set();
 
-                 //}
 
-                 //_trigExhaustPressureOK.CLK = !IsExhaustPressureOK;
 
-                 //if (_trigExhaustPressureOK.Q)
 
-                 //{
 
-                 //    PumpExhaustPressureNotOK.Set();
 
-                 //}
 
-             }
 
-             catch (Exception ex)
 
-             {
 
-                 LOG.Write(ex);
 
-             }
 
-         }
 
-         public void Reset()
 
-         {
 
-           
 
-         }
 
-     }
 
- }
 
 
  |