							- using Aitex.Core.RT.Routine;
 
- using Aitex.Core.RT.SCCore;
 
- using VirgoRT.Devices;
 
- namespace VirgoRT.Modules.PMs
 
- {
 
-     class VentRoutine : PMRoutineBase, IRoutine
 
-     {
 
-         private enum VentSequence
 
-         {
 
-             kCloseValves,
 
-             kOpenSoftVentValve,
 
-             kOpenFastVentValve,
 
-             kVentToPrecision,
 
-             kVentDelay,
 
-             kCloseVentValve,
 
-             kEnd,
 
-             kCheckLidSignal,
 
-             kCheckSlitDoor,
 
-             kCheckThrottleValveStatus,
 
-             kCheckN2,
 
-             kOpenProcessValve,
 
-             kOpenN2Supply,
 
-             kCheckChamberPressure,
 
-             kCheckATM
 
-         }
 
-         private int _ventTime;
 
-         private int _ventTimeDelay = 1;  //执行Vent程序时(自动或手动Vent),先关闭PV2,延时2秒后打开PV3。
 
-         private int _checkATMTimeout = 90;
 
-         public VentRoutine(JetPM chamber) : base(chamber)
 
-         {
 
-             Name = "vent";
 
-             bUINotify = true;
 
-         }
 
-         public Result Start(params object[] objs)
 
-         {
 
-             // 预检查
 
-             if (CheckLid() == Result.RUN &&
 
-                 CheckSlitDoor() == Result.RUN &&
 
-                 CheckCDA() == Result.RUN)
 
-             {
 
-                 Reset();
 
-                 _chamber.CloseValves();
 
-                 //_PressureTrip1 = SC.GetValue<int>($"{Module}.Pump.PressureTrip1") * 1000;
 
-                 _ventTime = (int)SC.GetValue<double>($"{Module}.VentTime");
 
-                 _checkATMTimeout = SC.GetValue<int>($"{Module}.CheckATMTimeout");
 
-                 _ventTimeDelay = SC.GetValue<int>($"{Module}.VentTimeDelay");
 
-                 Notify("开始");
 
-                 return Result.RUN;
 
-             }
 
-             return Result.FAIL;
 
-         }
 
-         public Result Monitor()
 
-         {
 
-             try
 
-             {
 
-                 //CheckThrottleValveFullOpen((int)VentSequence.kCheckThrottleValveStatus);
 
-                 // 开阀
 
-                 //OpenValve((int)VentSequence.kOpenSoftVentValve, ValveType.PURGE, true);
 
-                 SetValve((int)VentSequence.kOpenProcessValve, ValveType.PROCESS, true);
 
-                 // 监控压力
 
-                 //CheckPressure((int)VentSequence.kCheckChamberPressure, _PressureTrip1, true, 30);
 
-                 // 开阀
 
-                 SetValve((int)VentSequence.kOpenFastVentValve, ValveType.FAST_VENT, true);
 
-                 CheckATM2((int)VentSequence.kCheckATM, true, _checkATMTimeout);
 
-                 // delay 3 seconds
 
-                 TimeDelay((int)VentSequence.kVentDelay, _ventTimeDelay);
 
-                 // 结束并关闭所有阀
 
-                 CloseAllValve((int)VentSequence.kCloseValves, 0);
 
-                 End((int)VentSequence.kEnd);
 
-             }
 
-             catch (RoutineBreakException)
 
-             {
 
-                 return Result.RUN;
 
-             }
 
-             catch (RoutineFaildException)
 
-             {
 
-                 //_chamber.OpenValve(ValveType.N2_SUPPLY, false);
 
-                 _chamber.SetValveOnOff(ValveType.FAST_VENT, false);
 
-                 _chamber.SetValveOnOff(ValveType.PURGE, false);
 
-                 _chamber.SetValveOnOff(ValveType.PROCESS, false);
 
-                 Notify("出错");
 
-                 return Result.FAIL;
 
-             }
 
-             catch (System.Exception ex)
 
-             {
 
-                 Stop(ex.Message);
 
-                 return Result.FAIL;
 
-             }
 
-             Notify("结束");
 
-             return Result.DONE;
 
-         }
 
-         public override void Abort()
 
-         {
 
-             _chamber.CloseValves();
 
-         }
 
-     }
 
- }
 
 
  |