- using System;
- using Aitex.Core.RT.Event;
- using Aitex.Core.RT.Routine;
- using Aitex.Core.RT.SCCore;
- using VirgoRT.Devices;
- namespace VirgoRT.Modules.PMs
- {
- class PumpDownRoutine : PMRoutineBase, IRoutine
- {
- private enum PumpSequence
- {
- kCheckLidSignal,
- kCheckSlitDoor,
- kCheckDryPumpStatus,
- kCloseValves,
- kOpenPumpingValve,
- kDelay,
- kCheckVAC,
- kCheckForelinePressure,
- kCheckThrottleValveStatus,
- kCheckATM,
- kOpenSoftPumpValve,
- kCloseSoftPumpValve,
- kFastPumpValve,
- kCloseFastPumpValve,
- kCheckChamberPressure,
- kCheckVACSignal,
- kEnd
- }
- private int _basePressure;
- private int _pumpValveDelay;
- private double _pumpTimeLimit;
- private readonly uint FORELINE_TARGET = 500;
- public PumpDownRoutine(JetPM chamber) : base(chamber)
- {
- Name = "PumpDown";
- bUINotify = true;
- }
- public void Terminate()
- {
- }
- public Result Start(params object[] objs)
- {
- // 预检查,必须关盖子
- if (CheckLid() == Result.RUN &&
- CheckSlitDoor() == Result.RUN)
- //&& CheckDryPump() == Result.RUN)
- {
- Reset();
- //关闭所有阀门
- _chamber.CloseValves();
- //_PressureTrip1 = SC.GetValue<int>($"{Module}.Pump.PressureTrip1") * 1000;
- _basePressure = (objs.Length == 1) ? Convert.ToInt32(objs[0]) : SC.GetValue<int>($"{Module}.Pump.PumpBasePressure");
- _pumpTimeLimit = SC.GetValue<double>($"{Module}.Pump.PumpTimeLimit");
- _pumpValveDelay = SC.GetValue<int>($"{Module}.Pump.PumpValveDelay");
- Notify("开始");
- return Result.RUN;
- }
- return Result.FAIL;
- }
- public Result Monitor()
- {
- try
- {
- CheckForeline((int)PumpSequence.kCheckForelinePressure, FORELINE_TARGET, 15);
- // open pumping valve
- SetValve((int)PumpSequence.kOpenSoftPumpValve, ValveType.SOFT_PUMP, true);
- CheckThrottleValveFullOpen((int)PumpSequence.kCheckThrottleValveStatus);
- TimeDelay((int)PumpSequence.kDelay, _pumpValveDelay);
- SetValve((int)PumpSequence.kFastPumpValve, ValveType.FAST_PUMP, true);
- SetValve((int)PumpSequence.kCloseFastPumpValve, ValveType.SOFT_PUMP, false);
- CheckATM2((int)PumpSequence.kCheckATM, false, 30);
- //CheckPressure((int)PumpSequence.kCheckChamberPressure, _PressureTrip1, false, 50);
- //OpenValve((int)PumpSequence.kCloseSoftPumpValve, ValveType.SOFT_PUMP, false);
- //检查VAC
- CheckVAC((int)PumpSequence.kCheckVACSignal, 90);
- CheckPressure((int)PumpSequence.kCheckVAC, _basePressure, false, (int)_pumpTimeLimit);
- End((int)PumpSequence.kEnd);
- }
- catch (RoutineBreakException)
- {
- return Result.RUN;
- }
- catch (RoutineFaildException)
- {
- Stop("出错");
- return Result.FAIL;
- }
- catch (Exception ex)
- {
- Stop(ex.Message);
- return Result.FAIL;
- }
- Notify("结束");
- return Result.DONE;
- }
- public override void Abort()
- {
- _chamber.CloseValves();
- }
- }
- }
|