123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182183184185186187188189190191192193194195196197198199200201202203204205206207208209210211212213214215216217218219220221222223224225226227228229230231232233234235236237238239240241242243244245246247248249250251252253254255256257258259260261262263264265266267268269270271272273274275276277278279280281282283284285286287288289290291292293294295296297298299300301302303304305306307308309310311312313314315316317318319320321322323324325326327328329330331332333334335336337338339340341342343344345346347348349350351352353354355356357358359360361362363364365366367368369370371372373374375376377378379380381382383384385386387388389390391392393394395396397398399400401402403404405406407408409410411412413414415416417418419420421422423424425426427428429430431432433 |
- <?xml version="1.0"?>
- <EquipmentVariables xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:xsd="http://www.w3.org/2001/XMLSchema">
- <SystemInfo clockFormat="yyMMddHHmmss" traceSampleMax="20" traceMaxCount="5" supportValidIpRestrict="false" validIps="" name="Virgo" version="3.6" />
- <CommunicationInfo remoteIpAddress="127.0.0.1" port="5000" supportHeartCheck="true" heartInterval="5" />
- <StatusVariables>
- <StatusVariable id="1" valueType="List" logicalName="AlarmsEnabled" eventTrigger="" units="" />
- <StatusVariable id="2" valueType="List" logicalName="AlarmsSet" eventTrigger="" units="" />
- <StatusVariable id="3" valueType="Ascii" logicalName="Clock" eventTrigger="" units="" />
- <StatusVariable id="4" valueType="U4" logicalName="ControlState" eventTrigger="" units="" />
- <StatusVariable id="5" valueType="List" logicalName="EventsEnabled" eventTrigger="" units="" />
- <StatusVariable id="6" valueType="Ascii" logicalName="PPExecName" eventTrigger="" units="" />
- <StatusVariable id="7" valueType="U1" logicalName="PreviousProcessState" eventTrigger="" units="" />
- <StatusVariable id="8" valueType="U1" logicalName="ProcessState" eventTrigger="" units="" />
- <StatusVariable id="9" valueType="U4" logicalName="SpoolCountActual" eventTrigger="" units="" />
- <StatusVariable id="10" valueType="U4" logicalName="SpoolCountTotal" eventTrigger="" units="" />
- <StatusVariable id="11" valueType="Ascii" logicalName="SpoolFullTime" eventTrigger="" units="" />
- <StatusVariable id="12" valueType="Ascii" logicalName="SpoolStartTime" eventTrigger="" units="" />
- <StatusVariable id="13" valueType="Ascii" logicalName="SpoolState" eventTrigger="" units="" />
- <StatusVariable id="14" valueType="Ascii" logicalName="SpoolSubstate" eventTrigger="" units="" />
- <StatusVariable id="1101" valueType="U4" logicalName="EquipmentMode" units="" eventTrigger=" " />
- <StatusVariable id="1102" valueType="U4" logicalName="EquipmentStatus" units="" eventTrigger=" " />
- <StatusVariable id="1103" valueType="List" logicalName="RecipeList" units="" eventTrigger=" " />
- <StatusVariable id="1201" valueType="Ascii" logicalName="System.IoPressureMeter.PressureMeterChamber.Feedback" units="" eventTrigger=" " />
- <StatusVariable id="1202" valueType="Ascii" logicalName="System.IoThrottleValve.ThrottleValve.TVPosition" units="" eventTrigger=" " />
- <StatusVariable id="1203" valueType="Ascii" logicalName="System.IoThrottleValve.ThrottleValve.TVPositionSetPoint" units="" eventTrigger=" " />
- <StatusVariable id="1204" valueType="Ascii" logicalName="System.IoThrottleValve.ThrottleValve.TVPressure" units="" eventTrigger=" " />
- <StatusVariable id="1205" valueType="Ascii" logicalName="System.IoThrottleValve.ThrottleValve.TVPressureSetPoint" units="" eventTrigger=" " />
- <StatusVariable id="1206" valueType="Ascii" logicalName="System.IoPump.MainPump.N2PressureValue" units="" eventTrigger=" " />
- <StatusVariable id="1207" valueType="Ascii" logicalName="System.IoPump.MainPump.WaterFlowValue" units="" eventTrigger=" " />
- <StatusVariable id="1208" valueType="Ascii" logicalName="System.IoRf.Rf.RFSetPoint" units="" eventTrigger=" " />
- <StatusVariable id="1209" valueType="Ascii" logicalName="System.IoRf.Rf.RFForwardPower" units="" eventTrigger=" " />
- <StatusVariable id="1210" valueType="Ascii" logicalName="System.IoRf.Rf.RFReflectPower" units="" eventTrigger=" " />
- <StatusVariable id="1211" valueType="Ascii" logicalName="System.IoRf.Rf.RFMatchPositionC1Feedback" units="" eventTrigger=" " />
- <StatusVariable id="1212" valueType="Ascii" logicalName="System.IoRf.Rf.RFMatchPositionC2Feedback" units="" eventTrigger=" " />
- <StatusVariable id="1213" valueType="Ascii" logicalName="System.IoRf.Rf.RFMatchPositionC1SetPoint" units="" eventTrigger=" " />
- <StatusVariable id="1214" valueType="Ascii" logicalName="System.IoRf.Rf.RFMatchPositionC2SetPoint" units="" eventTrigger=" " />
- <StatusVariable id="1215" valueType="Ascii" logicalName="System.IoRf.Rf.RFFrequency" units="" eventTrigger=" " />
- <StatusVariable id="1216" valueType="Ascii" logicalName="System.IoRf.Rf.RFDuty" units="" eventTrigger=" " />
- <StatusVariable id="1217" valueType="Ascii" logicalName="System.IoMfc.MfcGas1.FeedBack" units="" eventTrigger=" " />
- <StatusVariable id="1218" valueType="Ascii" logicalName="System.IoMfc.MfcGas1.SetPoint" units="" eventTrigger=" " />
- <StatusVariable id="1219" valueType="Ascii" logicalName="System.IoMfc.MfcGas2.FeedBack" units="" eventTrigger=" " />
- <StatusVariable id="1220" valueType="Ascii" logicalName="System.IoMfc.MfcGas2.SetPoint" units="" eventTrigger=" " />
- <StatusVariable id="1221" valueType="Ascii" logicalName="System.IoMfc.MfcGas3.FeedBack" units="" eventTrigger=" " />
- <StatusVariable id="1222" valueType="Ascii" logicalName="System.IoMfc.MfcGas3.SetPoint" units="" eventTrigger=" " />
- <StatusVariable id="1223" valueType="Ascii" logicalName="System.IoMfc.MfcGas4.FeedBack" units="" eventTrigger=" " />
- <StatusVariable id="1224" valueType="Ascii" logicalName="System.IoMfc.MfcGas4.SetPoint" units="" eventTrigger=" " />
- <StatusVariable id="1225" valueType="Ascii" logicalName="System.IoMfc.MfcGas5.FeedBack" units="" eventTrigger=" " />
- <StatusVariable id="1226" valueType="Ascii" logicalName="System.IoMfc.MfcGas5.SetPoint" units="" eventTrigger=" " />
- <StatusVariable id="10001" valueType="Ascii" logicalName="LP1.SlotMap" units="" eventTrigger=" " />
- <StatusVariable id="10002" valueType="U4" logicalName="LP1.CassettePresent" units="" eventTrigger=" " />
- <StatusVariable id="10003" valueType="U4" logicalName="LP1.IsWaferProtrude" units="" eventTrigger=" " />
- <StatusVariable id="20001" valueType="Ascii" logicalName="LP2.SlotMap" units="" eventTrigger=" " />
- <StatusVariable id="20002" valueType="U4" logicalName="LP2.CassettePresent" units="" eventTrigger=" " />
- <StatusVariable id="20003" valueType="U4" logicalName="LP2.IsWaferProtrude" units="" eventTrigger=" " />
- <StatusVariable id="430001" valueType="Ascii" logicalName="PMA.IoPressureMeter.PressureMeterChamber.Feedback" units="" eventTrigger=" " />
- <StatusVariable id="430002" valueType="Ascii" logicalName="PMA.IoThrottleValve.ThrottleValve.TVPosition" units="" eventTrigger=" " />
- <StatusVariable id="430003" valueType="Ascii" logicalName="PMA.IoThrottleValve.ThrottleValve.TVPositionSetPoint" units="" eventTrigger=" " />
- <StatusVariable id="430004" valueType="Ascii" logicalName="PMA.IoThrottleValve.ThrottleValve.TVPressure" units="" eventTrigger=" " />
- <StatusVariable id="430005" valueType="Ascii" logicalName="PMA.IoThrottleValve.ThrottleValve.TVPressureSetPoint" units="" eventTrigger=" " />
- <StatusVariable id="430006" valueType="Ascii" logicalName="PMA.IoPump.MainPump.N2PressureValue" units="" eventTrigger=" " />
- <StatusVariable id="430007" valueType="Ascii" logicalName="PMA.IoPump.MainPump.WaterFlowValue" units="" eventTrigger=" " />
- <StatusVariable id="430008" valueType="Ascii" logicalName="PMA.IoRf.Rf.RFSetPoint" units="" eventTrigger=" " />
- <StatusVariable id="430009" valueType="Ascii" logicalName="PMA.IoRf.Rf.RFForwardPower" units="" eventTrigger=" " />
- <StatusVariable id="430010" valueType="Ascii" logicalName="PMA.IoRf.Rf.RFReflectPower" units="" eventTrigger=" " />
- <StatusVariable id="430011" valueType="Ascii" logicalName="PMA.IoRf.Rf.RFMatchPositionC1Feedback" units="" eventTrigger=" " />
- <StatusVariable id="430012" valueType="Ascii" logicalName="PMA.IoRf.Rf.RFMatchPositionC2Feedback" units="" eventTrigger=" " />
- <StatusVariable id="430013" valueType="Ascii" logicalName="PMA.IoRf.Rf.RFMatchPositionC1SetPoint" units="" eventTrigger=" " />
- <StatusVariable id="430014" valueType="Ascii" logicalName="PMA.IoRf.Rf.RFMatchPositionC2SetPoint" units="" eventTrigger=" " />
- <StatusVariable id="430015" valueType="Ascii" logicalName="PMA.IoRf.Rf.RFFrequency" units="" eventTrigger=" " />
- <StatusVariable id="430016" valueType="Ascii" logicalName="PMA.IoRf.Rf.RFDuty" units="" eventTrigger=" " />
- <StatusVariable id="430017" valueType="Ascii" logicalName="PMA.IoMfc.MfcGas1.FeedBack" units="" eventTrigger=" " />
- <StatusVariable id="430018" valueType="Ascii" logicalName="PMA.IoMfc.MfcGas1.SetPoint" units="" eventTrigger=" " />
- <StatusVariable id="430019" valueType="Ascii" logicalName="PMA.IoMfc.MfcGas2.FeedBack" units="" eventTrigger=" " />
- <StatusVariable id="430020" valueType="Ascii" logicalName="PMA.IoMfc.MfcGas2.SetPoint" units="" eventTrigger=" " />
- <StatusVariable id="430021" valueType="Ascii" logicalName="PMA.IoMfc.MfcGas3.FeedBack" units="" eventTrigger=" " />
- <StatusVariable id="430022" valueType="Ascii" logicalName="PMA.IoMfc.MfcGas3.SetPoint" units="" eventTrigger=" " />
- <StatusVariable id="430023" valueType="Ascii" logicalName="PMA.IoMfc.MfcGas4.FeedBack" units="" eventTrigger=" " />
- <StatusVariable id="430024" valueType="Ascii" logicalName="PMA.IoMfc.MfcGas4.SetPoint" units="" eventTrigger=" " />
- <StatusVariable id="430025" valueType="Ascii" logicalName="PMA.IoMfc.MfcGas5.FeedBack" units="" eventTrigger=" " />
- <StatusVariable id="430026" valueType="Ascii" logicalName="PMA.IoMfc.MfcGas5.SetPoint" units="" eventTrigger=" " />
- <StatusVariable id="430027" valueType="Ascii" logicalName="PMA.BiasMatch.C1" units="" eventTrigger=" " />
- <StatusVariable id="430028" valueType="Ascii" logicalName="PMA.BiasMatch.C2" units="" eventTrigger=" " />
- <StatusVariable id="430029" valueType="Ascii" logicalName="PMA.BiasMatch.MatchProcessMode" units="" eventTrigger=" " />
- <StatusVariable id="430030" valueType="Ascii" logicalName="PMA.BiasMatch.VPP" units="" eventTrigger=" " />
- <StatusVariable id="430031" valueType="Ascii" logicalName="PMA.BiasRf.ForwardPower" units="" eventTrigger=" " />
- <StatusVariable id="430032" valueType="Ascii" logicalName="PMA.BiasRf.Frequency" units="" eventTrigger=" " />
- <StatusVariable id="430033" valueType="Ascii" logicalName="PMA.BiasRf.PowerSetPoint" units="" eventTrigger=" " />
- <StatusVariable id="430034" valueType="Ascii" logicalName="PMA.BiasRf.PulsingDutyCycle" units="" eventTrigger=" " />
- <StatusVariable id="430035" valueType="Ascii" logicalName="PMA.BiasRf.PulsingFrequency" units="" eventTrigger=" " />
- <StatusVariable id="430036" valueType="Ascii" logicalName="PMA.BiasRf.ReflectPower" units="" eventTrigger=" " />
- <StatusVariable id="430037" valueType="Ascii" logicalName="PMA.ChamberPressure" units="" eventTrigger=" " />
- <StatusVariable id="430038" valueType="Ascii" logicalName="PMA.Chiller.ControlTcFeedback" units="" eventTrigger=" " />
- <StatusVariable id="430039" valueType="Ascii" logicalName="PMA.Chiller.ControlTcSetPoint" units="" eventTrigger=" " />
- <StatusVariable id="430040" valueType="Ascii" logicalName="PMA.Chiller.CoolantInletTempFeedback" units="" eventTrigger=" " />
- <StatusVariable id="430041" valueType="Ascii" logicalName="PMA.Chiller.CoolantOutletTempFeedback" units="" eventTrigger=" " />
- <StatusVariable id="430042" valueType="Ascii" logicalName="PMA.Chiller.Temperature" units="" eventTrigger=" " />
- <StatusVariable id="430043" valueType="Ascii" logicalName="PMA.ForelineGauge.Value" units="" eventTrigger=" " />
- <StatusVariable id="430044" valueType="Ascii" logicalName="PMA.IoHeater.ForelineHeater.ControlTcFeedback" units="" eventTrigger=" " />
- <StatusVariable id="430045" valueType="Ascii" logicalName="PMA.IoHeater.ForelineHeater.ControlTcSetPoint" units="" eventTrigger=" " />
- <StatusVariable id="430046" valueType="Ascii" logicalName="PMA.IoHeater.ForelineHeater.ControlTcSetPointView" units="" eventTrigger=" " />
- <StatusVariable id="430047" valueType="Ascii" logicalName="PMA.IoHeater.ForelineHeater.CoolantInletTempFeedback" units="" eventTrigger=" " />
- <StatusVariable id="430048" valueType="Ascii" logicalName="PMA.IoHeater.ForelineHeater.CoolantOutletTempFeedback" units="" eventTrigger=" " />
- <StatusVariable id="430049" valueType="Ascii" logicalName="PMA.IoHeater.ForelineHeater.MonitorTcFeedback" units="" eventTrigger=" " />
- <StatusVariable id="430050" valueType="Ascii" logicalName="PMA.IoHeater.HeaterChamber.ControlTcFeedback" units="" eventTrigger=" " />
- <StatusVariable id="430051" valueType="Ascii" logicalName="PMA.IoHeater.HeaterChamber.ControlTcSetPoint" units="" eventTrigger=" " />
- <StatusVariable id="430052" valueType="Ascii" logicalName="PMA.IoHeater.HeaterChamber.ControlTcSetPointView" units="" eventTrigger=" " />
- <StatusVariable id="430053" valueType="Ascii" logicalName="PMA.IoHeater.HeaterChamber.CoolantInletTempFeedback" units="" eventTrigger=" " />
- <StatusVariable id="430054" valueType="Ascii" logicalName="PMA.IoHeater.HeaterChamber.CoolantOutletTempFeedback" units="" eventTrigger=" " />
- <StatusVariable id="430055" valueType="Ascii" logicalName="PMA.IoHeater.HeaterChamber.MonitorTcFeedback" units="" eventTrigger=" " />
- <StatusVariable id="430056" valueType="Ascii" logicalName="PMA.PressureGauge.Value" units="" eventTrigger=" " />
- <StatusVariable id="430057" valueType="Ascii" logicalName="PMA.ProcessGauge.Value" units="" eventTrigger=" " />
- <StatusVariable id="430058" valueType="Ascii" logicalName="PMA.Rf.ForwardPower" units="" eventTrigger=" " />
- <StatusVariable id="430059" valueType="Ascii" logicalName="PMA.Rf.Frequency" units="" eventTrigger=" " />
- <StatusVariable id="430060" valueType="Ascii" logicalName="PMA.Rf.PowerSetPoint" units="" eventTrigger=" " />
- <StatusVariable id="430061" valueType="Ascii" logicalName="PMA.Rf.PulsingDutyCycle" units="" eventTrigger=" " />
- <StatusVariable id="430062" valueType="Ascii" logicalName="PMA.Rf.PulsingFrequency" units="" eventTrigger=" " />
- <StatusVariable id="430063" valueType="Ascii" logicalName="PMA.Rf.ReflectPower" units="" eventTrigger=" " />
- <StatusVariable id="430064" valueType="Ascii" logicalName="PMA.StepNo" units="" eventTrigger=" " />
- <StatusVariable id="430065" valueType="Ascii" logicalName="PMA.RecipeProcessTime" units="s" eventTrigger=" " />
- <StatusVariable id="430066" valueType="Ascii" logicalName="PMA.RecipeStepTimeElapsed" units="s" eventTrigger=" " />
- <StatusVariable id="430067" valueType="Ascii" logicalName="PMA.RecipeStepTimeSetPoint" units="s" eventTrigger=" " />
- <StatusVariable id="440001" valueType="Ascii" logicalName="PMB.IoPressureMeter.PressureMeterChamber.Feedback" units="" eventTrigger=" " />
- <StatusVariable id="440002" valueType="Ascii" logicalName="PMB.IoThrottleValve.ThrottleValve.TVPosition" units="" eventTrigger=" " />
- <StatusVariable id="440003" valueType="Ascii" logicalName="PMB.IoThrottleValve.ThrottleValve.TVPositionSetPoint" units="" eventTrigger=" " />
- <StatusVariable id="440004" valueType="Ascii" logicalName="PMB.IoThrottleValve.ThrottleValve.TVPressure" units="" eventTrigger=" " />
- <StatusVariable id="440005" valueType="Ascii" logicalName="PMB.IoThrottleValve.ThrottleValve.TVPressureSetPoint" units="" eventTrigger=" " />
- <StatusVariable id="440006" valueType="Ascii" logicalName="PMB.IoPump.MainPump.N2PressureValue" units="" eventTrigger=" " />
- <StatusVariable id="440007" valueType="Ascii" logicalName="PMB.IoPump.MainPump.WaterFlowValue" units="" eventTrigger=" " />
- <StatusVariable id="440008" valueType="Ascii" logicalName="PMB.IoRf.Rf.RFSetPoint" units="" eventTrigger=" " />
- <StatusVariable id="440009" valueType="Ascii" logicalName="PMB.IoRf.Rf.RFForwardPower" units="" eventTrigger=" " />
- <StatusVariable id="440010" valueType="Ascii" logicalName="PMB.IoRf.Rf.RFReflectPower" units="" eventTrigger=" " />
- <StatusVariable id="440011" valueType="Ascii" logicalName="PMB.IoRf.Rf.RFMatchPositionC1Feedback" units="" eventTrigger=" " />
- <StatusVariable id="440012" valueType="Ascii" logicalName="PMB.IoRf.Rf.RFMatchPositionC2Feedback" units="" eventTrigger=" " />
- <StatusVariable id="440013" valueType="Ascii" logicalName="PMB.IoRf.Rf.RFMatchPositionC1SetPoint" units="" eventTrigger=" " />
- <StatusVariable id="440014" valueType="Ascii" logicalName="PMB.IoRf.Rf.RFMatchPositionC2SetPoint" units="" eventTrigger=" " />
- <StatusVariable id="440015" valueType="Ascii" logicalName="PMB.IoRf.Rf.RFFrequency" units="" eventTrigger=" " />
- <StatusVariable id="440016" valueType="Ascii" logicalName="PMB.IoRf.Rf.RFDuty" units="" eventTrigger=" " />
- <StatusVariable id="440017" valueType="Ascii" logicalName="PMB.IoMfc.MfcGas1.FeedBack" units="" eventTrigger=" " />
- <StatusVariable id="440018" valueType="Ascii" logicalName="PMB.IoMfc.MfcGas1.SetPoint" units="" eventTrigger=" " />
- <StatusVariable id="440019" valueType="Ascii" logicalName="PMB.IoMfc.MfcGas2.FeedBack" units="" eventTrigger=" " />
- <StatusVariable id="440020" valueType="Ascii" logicalName="PMB.IoMfc.MfcGas2.SetPoint" units="" eventTrigger=" " />
- <StatusVariable id="440021" valueType="Ascii" logicalName="PMB.IoMfc.MfcGas3.FeedBack" units="" eventTrigger=" " />
- <StatusVariable id="440022" valueType="Ascii" logicalName="PMB.IoMfc.MfcGas3.SetPoint" units="" eventTrigger=" " />
- <StatusVariable id="440023" valueType="Ascii" logicalName="PMB.IoMfc.MfcGas4.FeedBack" units="" eventTrigger=" " />
- <StatusVariable id="440024" valueType="Ascii" logicalName="PMB.IoMfc.MfcGas4.SetPoint" units="" eventTrigger=" " />
- <StatusVariable id="440025" valueType="Ascii" logicalName="PMB.IoMfc.MfcGas5.FeedBack" units="" eventTrigger=" " />
- <StatusVariable id="440026" valueType="Ascii" logicalName="PMB.IoMfc.MfcGas5.SetPoint" units="" eventTrigger=" " />
- <StatusVariable id="440027" valueType="Ascii" logicalName="PMB.BiasMatch.C1" units="" eventTrigger=" " />
- <StatusVariable id="440028" valueType="Ascii" logicalName="PMB.BiasMatch.C2" units="" eventTrigger=" " />
- <StatusVariable id="440029" valueType="Ascii" logicalName="PMB.BiasMatch.MatchProcessMode" units="" eventTrigger=" " />
- <StatusVariable id="440030" valueType="Ascii" logicalName="PMB.BiasMatch.VPP" units="" eventTrigger=" " />
- <StatusVariable id="440031" valueType="Ascii" logicalName="PMB.BiasRf.ForwardPower" units="" eventTrigger=" " />
- <StatusVariable id="440032" valueType="Ascii" logicalName="PMB.BiasRf.Frequency" units="" eventTrigger=" " />
- <StatusVariable id="440033" valueType="Ascii" logicalName="PMB.BiasRf.PowerSetPoint" units="" eventTrigger=" " />
- <StatusVariable id="440034" valueType="Ascii" logicalName="PMB.BiasRf.PulsingDutyCycle" units="" eventTrigger=" " />
- <StatusVariable id="440035" valueType="Ascii" logicalName="PMB.BiasRf.PulsingFrequency" units="" eventTrigger=" " />
- <StatusVariable id="440036" valueType="Ascii" logicalName="PMB.BiasRf.ReflectPower" units="" eventTrigger=" " />
- <StatusVariable id="440037" valueType="Ascii" logicalName="PMB.ChamberPressure" units="" eventTrigger=" " />
- <StatusVariable id="440038" valueType="Ascii" logicalName="PMB.Chiller.ControlTcFeedback" units="" eventTrigger=" " />
- <StatusVariable id="440039" valueType="Ascii" logicalName="PMB.Chiller.ControlTcSetPoint" units="" eventTrigger=" " />
- <StatusVariable id="440040" valueType="Ascii" logicalName="PMB.Chiller.CoolantInletTempFeedback" units="" eventTrigger=" " />
- <StatusVariable id="440041" valueType="Ascii" logicalName="PMB.Chiller.CoolantOutletTempFeedback" units="" eventTrigger=" " />
- <StatusVariable id="440042" valueType="Ascii" logicalName="PMB.Chiller.Temperature" units="" eventTrigger=" " />
- <StatusVariable id="440043" valueType="Ascii" logicalName="PMB.ForelineGauge.Value" units="" eventTrigger=" " />
- <StatusVariable id="440044" valueType="Ascii" logicalName="PMB.IoHeater.ForelineHeater.ControlTcFeedback" units="" eventTrigger=" " />
- <StatusVariable id="440045" valueType="Ascii" logicalName="PMB.IoHeater.ForelineHeater.ControlTcSetPoint" units="" eventTrigger=" " />
- <StatusVariable id="440046" valueType="Ascii" logicalName="PMB.IoHeater.ForelineHeater.ControlTcSetPointView" units="" eventTrigger=" " />
- <StatusVariable id="440047" valueType="Ascii" logicalName="PMB.IoHeater.ForelineHeater.CoolantInletTempFeedback" units="" eventTrigger=" " />
- <StatusVariable id="440048" valueType="Ascii" logicalName="PMB.IoHeater.ForelineHeater.CoolantOutletTempFeedback" units="" eventTrigger=" " />
- <StatusVariable id="440049" valueType="Ascii" logicalName="PMB.IoHeater.ForelineHeater.MonitorTcFeedback" units="" eventTrigger=" " />
- <StatusVariable id="440050" valueType="Ascii" logicalName="PMB.IoHeater.HeaterChamber.ControlTcFeedback" units="" eventTrigger=" " />
- <StatusVariable id="440051" valueType="Ascii" logicalName="PMB.IoHeater.HeaterChamber.ControlTcSetPoint" units="" eventTrigger=" " />
- <StatusVariable id="440052" valueType="Ascii" logicalName="PMB.IoHeater.HeaterChamber.ControlTcSetPointView" units="" eventTrigger=" " />
- <StatusVariable id="440053" valueType="Ascii" logicalName="PMB.IoHeater.HeaterChamber.CoolantInletTempFeedback" units="" eventTrigger=" " />
- <StatusVariable id="440054" valueType="Ascii" logicalName="PMB.IoHeater.HeaterChamber.CoolantOutletTempFeedback" units="" eventTrigger=" " />
- <StatusVariable id="440055" valueType="Ascii" logicalName="PMB.IoHeater.HeaterChamber.MonitorTcFeedback" units="" eventTrigger=" " />
- <StatusVariable id="440056" valueType="Ascii" logicalName="PMB.PressureGauge.Value" units="" eventTrigger=" " />
- <StatusVariable id="440057" valueType="Ascii" logicalName="PMB.ProcessGauge.Value" units="" eventTrigger=" " />
- <StatusVariable id="440058" valueType="Ascii" logicalName="PMB.Rf.ForwardPower" units="" eventTrigger=" " />
- <StatusVariable id="440059" valueType="Ascii" logicalName="PMB.Rf.Frequency" units="" eventTrigger=" " />
- <StatusVariable id="440060" valueType="Ascii" logicalName="PMB.Rf.PowerSetPoint" units="" eventTrigger=" " />
- <StatusVariable id="440061" valueType="Ascii" logicalName="PMB.Rf.PulsingDutyCycle" units="" eventTrigger=" " />
- <StatusVariable id="440062" valueType="Ascii" logicalName="PMB.Rf.PulsingFrequency" units="" eventTrigger=" " />
- <StatusVariable id="440063" valueType="Ascii" logicalName="PMB.Rf.ReflectPower" units="" eventTrigger=" " />
- <StatusVariable id="440064" valueType="Ascii" logicalName="PMB.StepNo" units="" eventTrigger=" " />
- <StatusVariable id="440065" valueType="Ascii" logicalName="PMB.RecipeProcessTime" units="s" eventTrigger=" " />
- <StatusVariable id="440066" valueType="Ascii" logicalName="PMB.RecipeStepTimeElapsed" units="s" eventTrigger=" " />
- <StatusVariable id="440067" valueType="Ascii" logicalName="PMB.RecipeStepTimeSetPoint" units="s" eventTrigger=" " />
- </StatusVariables>
- <EquipmentConstants>
- <EquipmentConstant id="2000" valueType="U2" logicalName="EstablishCommunicationsTimeout" value="2" min="0" max="100" units="" defaultValue="" eventTrigger="" />
- <EquipmentConstant id="2001" valueType="U4" logicalName="FA.SpoolingMaxTransmit" value="100" min="0" max="100" units="" defaultValue="" eventTrigger="" />
- <EquipmentConstant id="2003" valueType="Boolean" logicalName="FA.SpoolingFullOverWrite" value="FALSE" min="" max="" units="" defaultValue="" eventTrigger="" />
- <EquipmentConstant id="2005" valueType="U4" logicalName="FA.SpoolingCapability" value="100" min="0" max="100" units="" defaultValue="" eventTrigger="" />
- <EquipmentConstant id="2006" valueType="Boolean" logicalName="SpoolEnabled" value="False" min="" max="" units="" defaultValue="" eventTrigger="" />
- <EquipmentConstant id="2007" valueType="U1" logicalName="TimeFormat" value="0" min="0" max="100" units="" defaultValue="" eventTrigger="" />
- </EquipmentConstants>
- <DataVariables>
- <DataVariable id="3007" valueType="I4" logicalName="ECChangedID" eventTrigger="" />
- <DataVariable id="3001" valueType="U4" logicalName="EventLimit" eventTrigger="" />
- <DataVariable id="3002" valueType="U4" logicalName="LimitVariable" eventTrigger="" />
- <DataVariable id="3003" valueType="Ascii" logicalName="PPChangeName" eventTrigger="" />
- <DataVariable id="3004" valueType="U2" logicalName="PPChangeStatus" eventTrigger="" />
- <DataVariable id="3005" valueType="Binary" logicalName="TransitionType" eventTrigger="" />
- <DataVariable id="3006" valueType="U4" logicalName="AlarmID" eventTrigger="" />
- <DataVariable id="3007" valueType="U4" logicalName="ECChangedID" eventTrigger="" />
- <DataVariable id="3101" valueType="Ascii" logicalName="EventName" eventTrigger="" />
- <DataVariable id="3102" valueType="Ascii" logicalName="LotID" eventTrigger="" />
- <DataVariable id="3103" valueType="Ascii" logicalName="RecipeID" eventTrigger="" />
- <DataVariable id="3104" valueType="Ascii" logicalName="JobID" eventTrigger="" />
- <DataVariable id="3105" valueType="Ascii" logicalName="PortID" eventTrigger="" />
- <DataVariable id="3106" valueType="Ascii" logicalName="SlotMap" eventTrigger="" />
- <DataVariable id="3107" valueType="Ascii" logicalName="SequenceID" eventTrigger="" />
- <DataVariable id="3108" valueType="Ascii" logicalName="StationName" eventTrigger="" />
- <DataVariable id="3109" valueType="Ascii" logicalName="RecipeStepNumber" eventTrigger="" />
- <DataVariable id="3110" valueType="Ascii" logicalName="SlotID" eventTrigger="" />
- <DataVariable id="3111" valueType="Ascii" logicalName="ProcessedWaferCount" eventTrigger="" />
- <DataVariable id="3112" valueType="Ascii" logicalName="CarrierID" eventTrigger="" />
- <DataVariable id="3113" valueType="Ascii" logicalName="TagData" eventTrigger="" />
- <DataVariable id="3114" valueType="List" logicalName="RecipeStepEndDataSummary" eventTrigger="" />
- <DataVariable id="3115" valueType="U4" logicalName="WaferProcessResult" eventTrigger="" />
- </DataVariables>
- <AlarmVariables>
- <AlarmVariable id="1" logicalName="EMOPressed" description="EMO Pressed" category="PersonalSafety" enabled="true"/>
- <AlarmVariable id="2" logicalName="LidError" description="Lid Error" category="PersonalSafety" enabled="true"/>
- <AlarmVariable id="3" logicalName="MFCOffline" description="MFC Offline" category="PersonalSafety" enabled="true"/>
- <AlarmVariable id="4" logicalName="VacuumGaugeError" description="Vacuum Gauge Error" category="PersonalSafety" enabled="true"/>
- <AlarmVariable id="5" logicalName="PressureOutOfTolerance" description="Pressure Out Of Tolerance" category="PersonalSafety" enabled="true"/>
- <AlarmVariable id="6" logicalName="PumpError" description="Pump Error" category="PersonalSafety" enabled="true"/>
- <AlarmVariable id="7" logicalName="RFGeneratorOffline" description="RF Generator Offline" category="PersonalSafety" enabled="true"/>
- <AlarmVariable id="8" logicalName="RFHighReflect" description="RF High Reflect" category="PersonalSafety" enabled="true"/>
- <AlarmVariable id="9" logicalName="RFHardwareInterlock" description="R FHardware Interlock" category="PersonalSafety" enabled="true"/>
- <AlarmVariable id="10" logicalName="GasFlowOutOfTolerance" description="Gas Flow Out Of Tolerance" category="PersonalSafety" enabled="true"/>
- <AlarmVariable id="11" logicalName="RFOutOfTolerance" description="RF Out Of Tolerance" category="PersonalSafety" enabled="true"/>
- <AlarmVariable id="12" logicalName="WaferProtrude" description="WaferProtrude" category="PersonalSafety" enabled="true"/>
- <AlarmVariable id="13" logicalName="EFEMSideDoorOpen" description="EFEM Side Door Open" category="PersonalSafety" enabled="true"/>
- <AlarmVariable id="14" logicalName="EFEMVacuumPressureError" description="EFEM Vacuum Pressure Error" category="PersonalSafety" enabled="true"/>
- <AlarmVariable id="15" logicalName="EFEMCDAError" description="EFEM CDA Error" category="PersonalSafety" enabled="true"/>
- <AlarmVariable id="16" logicalName="EFEMFlowGaugeSensorError" description="EFEM Flow Gauge Sensor Error" category="PersonalSafety" enabled="true"/>
- <AlarmVariable id="17" logicalName="EFEMLeakageAlarm" description="EFEM Leakage Alarm" category="PersonalSafety" enabled="true"/>
- <AlarmVariable id="18" logicalName="EFEMIonizerAlarm" description="EFEM Ionizer Alarm" category="PersonalSafety" enabled="true"/>
- <AlarmVariable id="19" logicalName="EFEMFFUAlarm" description="EFEM FFU Alarm" category="PersonalSafety" enabled="true"/>
- <AlarmVariable id="20" logicalName="EFEMOffline" description="EFEM Offline" category="PersonalSafety" enabled="true"/>
- <AlarmVariable id="21" logicalName="EFEMCommunicationError" description="EFEM Communication Error" category="PersonalSafety" enabled="true"/>
- <AlarmVariable id="22" logicalName="WaferTransferFailed" description="Wafer Transfer Failed" category="PersonalSafety" enabled="true"/>
- <AlarmVariable id="23" logicalName="EFEMError" description="EFEM Operation failed" category="PersonalSafety" enabled="true"/>
- <AlarmVariable id="24" logicalName="RecipeFileInvalid" description="Recipe File Invalid" category="PersonalSafety" enabled="true"/>
- <AlarmVariable id="25" logicalName="ALARM_EVENT" description="System Error" category="PersonalSafety" enabled="true"/>
- </AlarmVariables>
- <Reports>
- <Report id="1" logicalName="HostDefinedReport_1">
- <Variables>
- <ReportVariable id="3" variableType="StatusVariable" logicalName="Clock" />
- <ReportVariable id="4" variableType="StatusVariable" logicalName="ControlState" />
- </Variables>
- </Report>
- <Report id="2" logicalName="ProcessingReport">
- <Variables>
- <ReportVariable id="3" varType="StatusVariable" logicalName="Clock" />
- <ReportVariable id="7" varType="StatusVariable" logicalName="PreviousProcessState" />
- </Variables>
- </Report>
- <Report id="4" logicalName="ProcessingStateChangedReport">
- <Variables>
- <ReportVariable id="3" varType="StatusVariable" logicalName="Clock" />
- <ReportVariable id="8" varType="StatusVariable" logicalName="ProcessState" />
- <ReportVariable id="7" varType="StatusVariable" logicalName="PreviousProcessState" />
- </Variables>
- </Report>
- <Report id="5" logicalName="ECChangedReport">
- <Variables>
- <ReportVariable id="3007" varType="DataVariable" logicalName="ECChangedID" />
- </Variables>
- </Report>
- <Report id="6" logicalName="PPChangedReport">
- <Variables>
- <ReportVariable id="3003" varType="DataVariable" logicalName="PPChangeName" />
- <ReportVariable id="3004" varType="DataVariable" logicalName="PPChangeStatus" />
- </Variables>
- </Report>
- <Report id="7" logicalName="PPSelectedReport">
- <Variables>
- <ReportVariable id="6" varType="StatusVariable" logicalName="PPExecName" />
- </Variables>
- </Report>
- <Report id="8" logicalName="AlarmEventReport">
- <Variables>
- <ReportVariable id="3006" varType="DataVariable" logicalName="AlarmID" />
- <ReportVariable id="3" varType="StatusVariable" logicalName="Clock" />
- <ReportVariable id="2" varType="StatusVariable" logicalName="AlarmsSet" />
- </Variables>
- </Report>
- </Reports>
- <CollectionEvents>
- <CollectionEvent id="1" logicalName="EquipmentOFFLINE" description="" enabled="true">
- <Reports>
- <int>1</int>
- </Reports>
- </CollectionEvent>
- <CollectionEvent id="2" logicalName="ControlStateLOCAL" description=" " enabled="true">
- <Reports>
- <int>1</int>
- </Reports>
- </CollectionEvent>
- <CollectionEvent id="3" logicalName="ControlStateREMOTE" description=" " enabled="true">
- <Reports>
- <int>1</int>
- </Reports>
- </CollectionEvent>
- <CollectionEvent id="4" logicalName="ProcessingStarted" description=" " enabled="true">
- <Reports>
- <int>2</int>
- </Reports>
- </CollectionEvent>
- <CollectionEvent id="5" logicalName="ProcessingCompleted" description=" " enabled="true">
- <Reports>
- <int>2</int>
- </Reports>
- </CollectionEvent>
- <CollectionEvent id="6" logicalName="ProcessingStopped" description=" " enabled="true">
- <Reports>
- <int>2</int>
- </Reports>
- </CollectionEvent>
- <CollectionEvent id="7" logicalName="ProcessingStateChanged" description=" " enabled="true">
- <Reports>
- <int>4</int>
- </Reports>
- </CollectionEvent>
- <CollectionEvent id="8" logicalName="EquipmentConstantChanged" description=" " enabled="true">
- <Reports>
- <int>5</int>
- </Reports>
- </CollectionEvent>
- <CollectionEvent id="9" logicalName="ProcessProgramChanged" description=" " enabled="true">
- <Reports>
- <int>6</int>
- </Reports>
- </CollectionEvent>
- <CollectionEvent id="10" logicalName="ProcessProgramSelected" description=" " enabled="true">
- <Reports>
- <int>7</int>
- </Reports>
- </CollectionEvent>
- <CollectionEvent id="11" logicalName="SpoolingActivated" description=" " enabled="true" />
- <CollectionEvent id="12" logicalName="SpoolingDeactivated" description=" " enabled="true" />
- <CollectionEvent id="13" logicalName="SpoolingFailed" description=" " enabled="true" />
- <CollectionEvent id="1001" logicalName="WaferLeftPosition" description=" " enabled="true" />
- <CollectionEvent id="1002" logicalName="WaferArrivePosition" description=" " enabled="true" />
- <CollectionEvent id="1101" logicalName="Port1LoadComplete" description=" " enabled="true" />
- <CollectionEvent id="1102" logicalName="Port1LoadFailed" description=" " enabled="true" />
- <CollectionEvent id="1103" logicalName="Port1UnloadComplete" description=" " enabled="true" />
- <CollectionEvent id="1104" logicalName="Port1UnloadFailed" description=" " enabled="true" />
- <CollectionEvent id="1105" logicalName="Port1CassetteArrive" description=" " enabled="true" />
- <CollectionEvent id="1106" logicalName="Port1CassetteRemoved" description=" " enabled="true" />
- <CollectionEvent id="1107" logicalName="Port1JobStarted" description=" " enabled="true" />
- <CollectionEvent id="1108" logicalName="Port1JobStopped" description=" " enabled="true" />
- <CollectionEvent id="1109" logicalName="Port1JobPaused" description=" " enabled="true" />
- <CollectionEvent id="1110" logicalName="Port1JobResumed" description=" " enabled="true" />
- <CollectionEvent id="1111" logicalName="Port1JobAborted" description=" " enabled="true" />
- <CollectionEvent id="1112" logicalName="Port1JobFinished" description=" " enabled="true" />
- <CollectionEvent id="1113" logicalName="Port1JobFailed" description=" " enabled="true" />
- <CollectionEvent id="1114" logicalName="Port1MappingComplete" description=" " enabled="true" />
- <CollectionEvent id="1115" logicalName="Port1MappingFailed" description=" " enabled="true" />
- <CollectionEvent id="1116" logicalName="Port1SequenceSelected" description=" " enabled="true" />
- <CollectionEvent id="1117" logicalName="Port1SequenceSelectFailed" description=" " enabled="true" />
- <CollectionEvent id="1118" logicalName="Port1JobWaferStart" description=" " enabled="true" />
- <CollectionEvent id="1119" logicalName="Port1JobWaferEnd" description=" " enabled="true" />
- <CollectionEvent id="1120" logicalName="Port1Clamped" description=" " enabled="true" />
- <CollectionEvent id="1121" logicalName="Port1Unclamped" description=" " enabled="true" />
- <CollectionEvent id="1122" logicalName="Port1IDRead" description=" " enabled="true" />
- <CollectionEvent id="1123" logicalName="Port1ReadIDFailed" description=" " enabled="true" />
- <CollectionEvent id="1124" logicalName="Port1IDWrite" description=" " enabled="true" />
- <CollectionEvent id="1125" logicalName="Port1WriteIDFailed" description=" " enabled="true" />
- <CollectionEvent id="1126" logicalName="Port1TagDataRead" description=" " enabled="true" />
- <CollectionEvent id="1127" logicalName="Port1ReadTagDataFailed" description=" " enabled="true" />
- <CollectionEvent id="1128" logicalName="Port1TagDataWrite" description=" " enabled="true" />
- <CollectionEvent id="1129" logicalName="Port1WriteTagDataFailed" description=" " enabled="true" />
- <CollectionEvent id="1201" logicalName="Port2LoadComplete" description=" " enabled="true" />
- <CollectionEvent id="1202" logicalName="Port2LoadFailed" description=" " enabled="true" />
- <CollectionEvent id="1203" logicalName="Port2UnloadComplete" description=" " enabled="true" />
- <CollectionEvent id="1204" logicalName="Port2UnloadFailed" description=" " enabled="true" />
- <CollectionEvent id="1205" logicalName="Port2CassetteArrive" description=" " enabled="true" />
- <CollectionEvent id="1206" logicalName="Port2CassetteRemoved" description=" " enabled="true" />
- <CollectionEvent id="1207" logicalName="Port2JobStarted" description=" " enabled="true" />
- <CollectionEvent id="1208" logicalName="Port2JobStopped" description=" " enabled="true" />
- <CollectionEvent id="1209" logicalName="Port2JobPaused" description=" " enabled="true" />
- <CollectionEvent id="1210" logicalName="Port2JobResumed" description=" " enabled="true" />
- <CollectionEvent id="1211" logicalName="Port2JobAborted" description=" " enabled="true" />
- <CollectionEvent id="1212" logicalName="Port2JobFinished" description=" " enabled="true" />
- <CollectionEvent id="1213" logicalName="Port2JobFailed" description=" " enabled="true" />
- <CollectionEvent id="1214" logicalName="Port2MappingComplete" description=" " enabled="true" />
- <CollectionEvent id="1215" logicalName="Port2MappingFailed" description=" " enabled="true" />
- <CollectionEvent id="1216" logicalName="Port2SequenceSelected" description=" " enabled="true" />
- <CollectionEvent id="1217" logicalName="Port2SequenceSelectFailed" description=" " enabled="true" />
- <CollectionEvent id="1218" logicalName="Port2JobWaferStart" description=" " enabled="true" />
- <CollectionEvent id="1219" logicalName="Port2JobWaferEnd" description=" " enabled="true" />
- <CollectionEvent id="1220" logicalName="Port2Clamped" description=" " enabled="true" />
- <CollectionEvent id="1221" logicalName="Port2Unclamped" description=" " enabled="true" />
- <CollectionEvent id="1222" logicalName="Port2IDRead" description=" " enabled="true" />
- <CollectionEvent id="1223" logicalName="Port2ReadIDFailed" description=" " enabled="true" />
- <CollectionEvent id="1224" logicalName="Port2IDWrite" description=" " enabled="true" />
- <CollectionEvent id="1225" logicalName="Port2WriteIDFailed" description=" " enabled="true" />
- <CollectionEvent id="1226" logicalName="Port2TagDataRead" description=" " enabled="true" />
- <CollectionEvent id="1227" logicalName="Port2ReadTagDataFailed" description=" " enabled="true" />
- <CollectionEvent id="1228" logicalName="Port2TagDataWrite" description=" " enabled="true" />
- <CollectionEvent id="1229" logicalName="Port2WriteTagDataFailed" description=" " enabled="true" />
- <CollectionEvent id="2101" logicalName="PM1RecipeStart" description=" " enabled="true" />
- <CollectionEvent id="2102" logicalName="PM1RecipeComplete" description=" " enabled="true" />
- <CollectionEvent id="2103" logicalName="PM1RecipeStepStart" description=" " enabled="true" />
- <CollectionEvent id="2104" logicalName="PM1RecipeStepEnd" description=" " enabled="true" />
- <CollectionEvent id="2105" logicalName="PM1RecipeFailed" description=" " enabled="true" />
- <CollectionEvent id="2106" logicalName="PM1WaferArrivedPosition" description=" " enabled="true" />
- <CollectionEvent id="2107" logicalName="PM1WaferLeftPosition" description=" " enabled="true" />
- <CollectionEvent id="2201" logicalName="PM2RecipeStart" description=" " enabled="true" />
- <CollectionEvent id="2202" logicalName="PM2RecipeComplete" description=" " enabled="true" />
- <CollectionEvent id="2203" logicalName="PM2RecipeStepStart" description=" " enabled="true" />
- <CollectionEvent id="2204" logicalName="PM2RecipeStepEnd" description=" " enabled="true" />
- <CollectionEvent id="2205" logicalName="PM2RecipeFailed" description=" " enabled="true" />
- <CollectionEvent id="2206" logicalName="PM2WaferArrivedPosition" description=" " enabled="true" />
- <CollectionEvent id="2207" logicalName="PM2WaferLeftPosition" description=" " enabled="true" />
- <CollectionEvent id="3101" logicalName="Aligner1WaferArrivedPosition" description=" " enabled="true" />
- <CollectionEvent id="3102" logicalName="Aligner1WaferLeftPosition" description=" " enabled="true" />
- <CollectionEvent id="3201" logicalName="Aligner2WaferArrivedPosition" description=" " enabled="true" />
- <CollectionEvent id="3202" logicalName="Aligner2WaferLeftPosition" description=" " enabled="true" />
- <CollectionEvent id="3301" logicalName="Cooling1WaferArrivedPosition" description=" " enabled="true" />
- <CollectionEvent id="3302" logicalName="Cooling1WaferLeftPosition" description=" " enabled="true" />
- <CollectionEvent id="3401" logicalName="Cooling2WaferArrivedPosition" description=" " enabled="true" />
- <CollectionEvent id="3402" logicalName="Cooling2WaferLeftPosition" description=" " enabled="true" />
- <CollectionEvent id="4001" logicalName="CassetteDoorOpen" description=" " enabled="true" />
- <CollectionEvent id="4002" logicalName="CassetteDoorClose" description=" " enabled="true" />
- </CollectionEvents>
- </EquipmentVariables>
|