123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182183184185186187188189190191192193194195196197198199200201202203204205206207208209210211212213214215216217218219220221222223224225226227228229230231232233234235236237238239240241242243244245246247248249250251252253254255256257258259260261262263264265266267268269270271272273274275276277278279280281282283284285286287288289290291292293294295296297298299300301302303304305306307308309310311 |
- using Aitex.Core.RT.DataCenter;
- using Aitex.Core.RT.Device;
- using Aitex.Core.RT.Log;
- using Aitex.Core.RT.OperationCenter;
- using Aitex.Core.Util;
- using MECF.Framework.Common.CommonData.Reservoir;
- using MECF.Framework.Common.IOCore;
- using MECF.Framework.Common.Persistent.Reservoirs;
- using MECF.Framework.Common.TwinCat;
- using MECF.Framework.Common.Utilities;
- using PunkHPX8_RT.Modules;
- using System;
- using System.Collections.Generic;
- using System.Linq;
- using System.Reflection;
- using System.Text;
- using System.Threading.Tasks;
- namespace PunkHPX8_RT.Devices.Reservoir
- {
- public class ReservoirDevice : BaseDevice, IDevice
- {
- #region 常量
- protected const string AUTO = "Auto";
- protected const string MANUAL = "Manual";
- protected const string DISABLE = "Disable";
- protected const string CA_PUMP_RUNNING="CaPumpRunning";
- protected const string AN_TOWER_HIGH="AnTowerHigh";
- protected const string AN_TOWER_LOW="AnTowerLow";
- protected const string CA_LEVEL="CaLevel";
- protected const string CA_WATER_LEVEL="CaWaterLevel";
- protected const string AN_FLOW="AnFlow";
- protected const string AN_PUMP_ENABLE="AnPumpEnable";
- protected const string AN_PUMP_SPEED="AnPumpSpeed";
- protected const string CA_FLOW="CaFlow";
- protected const string CA_PUMP_ENABLE="CaPumpEnable";
- protected const string CA_PUMP_SPEED="CaPumpSpeed";
- protected const string RETURN_VALVE_OPENING="ReturnValveOpening";
- protected const string RETURN_VALVE="ReturnValve";
- protected const string RETURN_VALVE_PERCENT="ReturnValvePercent";
- protected const string CA_DI_REPLEN="CaDiReplen";
- protected const string AN_DI_REPLEN="AnDiReplen";
- protected const string SAMPLE_OUT="SampleOut";
- protected const string DEGAS_ENABLE="DegasEnable";
- protected const string HED_FLOW="HedFlow";
- protected const string HED_FLOW_ENABLE="HedFlowEnable";
- protected const string PH_FLOW_VALVE="PhFlowValve";
- protected const string PH_VALUE="PhValue";
- #endregion
- #region 内部变量
- /// <summary>
- /// Prewet 持久性数值对象
- /// </summary>
- private ReservoirsPersistentValue _persistentValue;
- /// <summary>
- /// 变量是否初始化字典
- /// </summary>
- private Dictionary<string, bool> _variableInitializeDic = new Dictionary<string, bool>();
- /// <summary>
- /// 数据
- /// </summary>
- private ReservoirData _reservoirData = new ReservoirData();
- /// <summary>
- /// 定时器
- /// </summary>
- private PeriodicJob _periodicJob;
- #endregion
- #region 属性
- /// <summary>
- /// 操作模式
- /// </summary>
- public string OperationMode { get { return _persistentValue.OperatingMode; } }
- /// <summary>
- /// 工程模式
- /// </summary>
- public string EngineerMode { get { return _persistentValue.RecipeOperatingMode; } }
- /// <summary>
- /// 是否自动
- /// </summary>
- public bool IsAuto { get { return _persistentValue.OperatingMode == AUTO; } }
- /// <summary>
- /// 数据
- /// </summary>
- public ReservoirData ReservoirData { get { return _reservoirData; } }
- #endregion
- /// <summary>
- /// 构造函数
- /// </summary>
- /// <param name="moduleName"></param>
- /// <param name="name"></param>
- public ReservoirDevice(string moduleName) : base(moduleName, moduleName, moduleName, moduleName)
- {
- }
- /// <summary>
- /// 初始化
- /// </summary>
- /// <returns></returns>
- public bool Initialize()
- {
- InitializeParameter();
- InitializeRoutine();
- SubscribeData();
- InitializeOperation();
- SubscribeValueAction();
- _periodicJob = new PeriodicJob(200, OnTimer, $"{Module}.Timer", true, true);
- return true;
- }
- /// <summary>
- /// 初始化参数
- /// </summary>
- private void InitializeParameter()
- {
- _persistentValue = ReservoirsPersistentManager.Instance.GetReservoirsPersistentValue(Module.ToString());
- if (_persistentValue == null)
- {
- LOG.WriteLog(eEvent.ERR_RESERVOIR, Module.ToString(), "Persistent Value Object is not exist");
- }
- }
- /// <summary>
- /// 初始化Routine
- /// </summary>
- private void InitializeRoutine()
- {
- }
- /// <summary>
- /// 订阅数据
- /// </summary>
- private void SubscribeData()
- {
- DATA.Subscribe($"{Module}.ReservoirData", () => _reservoirData, SubscriptionAttribute.FLAG.IgnoreSaveDB);
- }
- /// <summary>
- /// 初始化Operation
- /// </summary>
- private void InitializeOperation()
- {
- OP.Subscribe($"{Module}.DisabledAction", DisabledOperation);
- OP.Subscribe($"{Module}.ManualAction", ManualOperation);
- OP.Subscribe($"{Module}.AutoAction", AutoOperation);
- OP.Subscribe($"{Module}.EngineeringModeAction", EngineeringModeOperation);
- OP.Subscribe($"{Module}.ProductionModeAction", ProductionModeOperation);
- }
- /// <summary>
- /// 订阅变量数值发生变化
- /// </summary>
- protected virtual void SubscribeValueAction()
- {
- IoSubscribeUpdateVariable(CA_PUMP_RUNNING);
- IoSubscribeUpdateVariable(AN_TOWER_HIGH);
- IoSubscribeUpdateVariable(AN_TOWER_LOW);
- IoSubscribeUpdateVariable(CA_LEVEL);
- IoSubscribeUpdateVariable(CA_WATER_LEVEL);
- IoSubscribeUpdateVariable(CA_PUMP_ENABLE);
- IoSubscribeUpdateVariable(CA_PUMP_SPEED);
- IoSubscribeUpdateVariable(CA_DI_REPLEN);
- IoSubscribeUpdateVariable(RETURN_VALVE);
- IoSubscribeUpdateVariable(RETURN_VALVE_OPENING);
- IoSubscribeUpdateVariable(RETURN_VALVE_PERCENT);
- IoSubscribeUpdateVariable(SAMPLE_OUT);
- }
- /// <summary>
- /// 订阅IO变量
- /// </summary>
- /// <param name="variable"></param>
- protected void IoSubscribeUpdateVariable(string variable)
- {
- _variableInitializeDic[variable] = false;
- IOModuleManager.Instance.SubscribeModuleVariable(Module, variable, UpdateVariableValue);
- }
- /// <summary>
- /// 更新变量数值
- /// </summary>
- /// <param name="variable"></param>
- /// <param name="value"></param>
- private void UpdateVariableValue(string variable, object value)
- {
- if (!_reservoirData.IsDataInitialized)
- {
- _reservoirData.IsDataInitialized = true;
- }
- PropertyInfo property = _reservoirData.GetType().GetProperty(variable);
- if (property != null)
- {
- property.SetValue(_reservoirData, value);
- }
- if (_variableInitializeDic.ContainsKey(variable) && !_variableInitializeDic[variable])
- {
- _variableInitializeDic[variable] = true;
- }
- }
- /// <summary>
- /// 定时器
- /// </summary>
- /// <returns></returns>
- protected virtual bool OnTimer()
- {
- return true;
- }
- #region Mode switch
- /// <summary>
- /// DisabledAction
- /// </summary>
- /// <param name="cmd"></param>
- /// <param name="param"></param>
- /// <returns></returns>
- private bool DisabledOperation(string cmd, object[] args)
- {
- string currentOperation = "Disabled";
- string preOperation = _persistentValue.OperatingMode;
- _persistentValue.OperatingMode = currentOperation;
- LOG.WriteLog(eEvent.INFO_RESERVOIR, Module, $"Operating mode is switched from {preOperation} to {currentOperation}");
-
- ReservoirsPersistentManager.Instance.UpdatePersistentValue(Module);
- return true;
- }
- /// <summary>
- /// ManualAction
- /// </summary>
- /// <param name="cmd"></param>
- /// <param name="param"></param>
- /// <returns></returns>
- private bool ManualOperation(string cmd, object[] args)
- {
- string currentOperation = "Manual";
- string preOperation = _persistentValue.OperatingMode;
-
- _persistentValue.OperatingMode = currentOperation;
- LOG.WriteLog(eEvent.INFO_RESERVOIR, Module, $"Operating mode is switched from {preOperation} to {currentOperation}");
-
- ReservoirsPersistentManager.Instance.UpdatePersistentValue(Module);
- return true;
- }
- /// <summary>
- /// AutoAction
- /// </summary>
- /// <param name="cmd"></param>
- /// <param name="param"></param>
- /// <returns></returns>
- private bool AutoOperation(string cmd, object[] args)
- {
- string currentOperation = "Auto";
- string preOperation = _persistentValue.OperatingMode;
- _persistentValue.OperatingMode = currentOperation;
- LOG.WriteLog(eEvent.INFO_RESERVOIR, Module, $"Operating mode is switched from {preOperation} to {currentOperation}");
-
- ReservoirsPersistentManager.Instance.UpdatePersistentValue(Module);
- return true;
- }
- /// <summary>
- /// EngineeringModeAction
- /// </summary>
- /// <param name="cmd"></param>
- /// <param name="param"></param>
- /// <returns></returns>
- private bool EngineeringModeOperation(string cmd, object[] args)
- {
- string currentRecipeOperation = "Engineering";
- if (_persistentValue != null)
- {
- _persistentValue.RecipeOperatingMode = currentRecipeOperation;
- }
- ReservoirsPersistentManager.Instance.UpdatePersistentValue(Module);
- return true;
- }
- /// <summary>
- /// ProductionAction
- /// </summary>
- /// <param name="cmd"></param>
- /// <param name="param"></param>
- /// <returns></returns>
- private bool ProductionModeOperation(string cmd, object[] args)
- {
- string currentRecipeOperation = "Production";
- if (_persistentValue != null)
- {
- _persistentValue.RecipeOperatingMode = currentRecipeOperation;
- }
- ReservoirsPersistentManager.Instance.UpdatePersistentValue(Module);
- return true;
- }
- #endregion
- /// <summary>
- /// 监控
- /// </summary>
- public void Monitor()
- {
- }
- public void Reset()
- {
- }
- public void Terminate()
- {
- }
- }
- }
|