@@ -244,6 +244,7 @@
|
|
<config default="2" name="RangePressure" nameView="RangePressure" description="pressure delta range" max="60" min="0" paramter="" tag="" unit="" type="Double"/>
|
|
<config default="2" name="RangePressure" nameView="RangePressure" description="pressure delta range" max="60" min="0" paramter="" tag="" unit="" type="Double"/>
|
|
<config default="5" name="DripValveOpenIdlePeriod" nameView="DripValveOpenIdlePeriod" max="60" min="0" description="idle time after total flow over start flow,then open drip valve." paramter="" tag="" unit="minute" type="Integer" />
|
|
<config default="5" name="DripValveOpenIdlePeriod" nameView="DripValveOpenIdlePeriod" max="60" min="0" description="idle time after total flow over start flow,then open drip valve." paramter="" tag="" unit="minute" type="Integer" />
|
|
<config default="3" name="ChamberUpDownCheckTime" nameView="ChamberUpDownCheckTime" max="60" min="0" description="check chamber is up/down time" paramter="" tag="" unit="s" type="Integer" />
|
|
<config default="3" name="ChamberUpDownCheckTime" nameView="ChamberUpDownCheckTime" max="60" min="0" description="check chamber is up/down time" paramter="" tag="" unit="s" type="Integer" />
|
|
|
|
+ <config default="3" name="FlowFaultHoldOffTime" nameView="FlowFaultHoldOffTime" max="60" min="0" description="TotalFlow Fault HoldOff Time" paramter="" tag="" unit="min" type="Integer" />
|
|
<configs name="PumpPressure" nameView="PumpPressure">
|
|
<configs name="PumpPressure" nameView="PumpPressure">
|
|
<config default="50.0" name="Error_Max" nameView="Error_Max" max="100.0" min="0" paramter="" tag="" unit="" type="Double" description="This value defines the maximum flow, in liters per minute, above which this interlock will transition to an Error state."/>
|
|
<config default="50.0" name="Error_Max" nameView="Error_Max" max="100.0" min="0" paramter="" tag="" unit="" type="Double" description="This value defines the maximum flow, in liters per minute, above which this interlock will transition to an Error state."/>
|
|
<config default="40.0" name="Warning_Max" nameView="Warning_Max" max="100.0" min="0" paramter="" tag="" unit="" type="Double" description="This value defines the maximum flow, in liters per minute, above which this interlock will transition to an Warning state. Note corresponding Error_Min/Error_Max testing supersedes this test."/>
|
|
<config default="40.0" name="Warning_Max" nameView="Warning_Max" max="100.0" min="0" paramter="" tag="" unit="" type="Double" description="This value defines the maximum flow, in liters per minute, above which this interlock will transition to an Warning state. Note corresponding Error_Min/Error_Max testing supersedes this test."/>
|
|
@@ -257,7 +258,7 @@
|
|
<config default="2.0" name="CellFlowStartLowLimit" nameView="TotalFlowStartLowLimit" max="100.0" min="0" description="the low limit of total flow in the start period." paramter="" tag="" unit="" type="Double"/>
|
|
<config default="2.0" name="CellFlowStartLowLimit" nameView="TotalFlowStartLowLimit" max="100.0" min="0" description="the low limit of total flow in the start period." paramter="" tag="" unit="" type="Double"/>
|
|
<config default="2000" name="DegasEnableDelayTime" nameView="DegasEnableDelayTime" max="60000.0" min="0" description="delay time of degas enable." paramter="" tag="" unit="ms" type="Integer" />
|
|
<config default="2000" name="DegasEnableDelayTime" nameView="DegasEnableDelayTime" max="60000.0" min="0" description="delay time of degas enable." paramter="" tag="" unit="ms" type="Integer" />
|
|
<config default="400" name="PurgeMotorSpeed" nameView="PurgeMotorSpeed" max="5000.0" min="0" description="rotation default velocity in homing period." paramter="" tag="" unit="rpm" type="Double" />
|
|
<config default="400" name="PurgeMotorSpeed" nameView="PurgeMotorSpeed" max="5000.0" min="0" description="rotation default velocity in homing period." paramter="" tag="" unit="rpm" type="Double" />
|
|
- </configs>
|
|
|
|
|
|
+ </configs>
|
|
</configs>
|
|
</configs>
|
|
<configs name="VPW1">
|
|
<configs name="VPW1">
|
|
<config default="2000" name="PutDownAfterDripClose" nameView="PutDownAfterDripClose" description="Delay time for put down chamber after drip valve close" max="60000" min="0" paramter="" tag="" unit="ms" type="Integer"></config>
|
|
<config default="2000" name="PutDownAfterDripClose" nameView="PutDownAfterDripClose" description="Delay time for put down chamber after drip valve close" max="60000" min="0" paramter="" tag="" unit="ms" type="Integer"></config>
|
|
@@ -269,6 +270,16 @@
|
|
<config default="5" name="FlowCheckDelay" nameView="FlowCheckDelay" description="After delay second to check flow" max="60" min="0" paramter="" tag="" unit="s" type="Integer"></config>
|
|
<config default="5" name="FlowCheckDelay" nameView="FlowCheckDelay" description="After delay second to check flow" max="60" min="0" paramter="" tag="" unit="s" type="Integer"></config>
|
|
<config default="5" name="DripValveOpenIdlePeriod" nameView="DripValveOpenIdlePeriod" description="DripValve Open Idle Period" max="60" min="0" paramter="" tag="" unit="min" type="Integer"></config>
|
|
<config default="5" name="DripValveOpenIdlePeriod" nameView="DripValveOpenIdlePeriod" description="DripValve Open Idle Period" max="60" min="0" paramter="" tag="" unit="min" type="Integer"></config>
|
|
</configs>
|
|
</configs>
|
|
|
|
+ <configs name="VPW2">
|
|
|
|
+ <config default="2000" name="PutDownAfterDripClose" nameView="PutDownAfterDripClose" description="Delay time for put down chamber after drip valve close" max="60000" min="0" paramter="" tag="" unit="ms" type="Integer"></config>
|
|
|
|
+ <config default="300" name="WaitForWaferTime" nameView="WaitForWaferTime" description="Wait for wafer to place into VPW" max="3600" min="0" paramter="" tag="" unit="s" type="Integer" visible="false"></config>
|
|
|
|
+ <config default="60" name="PumpDownWarningTime" nameView="PumpDownWarningTime" description="waring time of vacuum pump down" max="3600" min="0" paramter="" tag="" unit="s" type="Integer"></config>
|
|
|
|
+ <config default="80" name="PumpDownTimeout" nameView="PumpDownTimeout" description="time out of vacuum pump down" max="3600" min="0" paramter="" tag="" unit="s" type="Integer"></config>
|
|
|
|
+ <config default="730" name="LidReleasePressure" nameView="LidReleasePressure" description="lid release pressure" max="10000" min="0" paramter="" tag="" unit="Torr" type="Integer"></config>
|
|
|
|
+ <config default="10" name="LidReleasePressureTimeout" nameView="LidReleasePressureTimeout" description="time out of lid release pressure" max="3600" min="0" paramter="" tag="" unit="s" type="Integer"></config>
|
|
|
|
+ <config default="5" name="FlowCheckDelay" nameView="FlowCheckDelay" description="After delay second to check flow" max="60" min="0" paramter="" tag="" unit="s" type="Integer"></config>
|
|
|
|
+ <config default="5" name="DripValveOpenIdlePeriod" nameView="DripValveOpenIdlePeriod" description="DripValve Open Idle Period" max="60" min="0" paramter="" tag="" unit="min" type="Integer"></config>
|
|
|
|
+ </configs>
|
|
<configs name="Linmot" nameView="Linmot">
|
|
<configs name="Linmot" nameView="Linmot">
|
|
<config default="5000" name="LinmotHoldoffMilliseconds" nameView="LinmotHoldoffMilliseconds" description="Linmot Hold off Milliseconds" max="10000" min="1" paramter="" tag="" unit="ms" type="Integer"></config>
|
|
<config default="5000" name="LinmotHoldoffMilliseconds" nameView="LinmotHoldoffMilliseconds" description="Linmot Hold off Milliseconds" max="10000" min="1" paramter="" tag="" unit="ms" type="Integer"></config>
|
|
</configs>
|
|
</configs>
|