12345678910111213141516171819202122232425262728293031323334353637383940414243444546474849505152535455565758596061626364656667686970717273747576777879808182838485868788899091929394959697 |
- <?xml version="1.0" encoding="utf-8"?>
- <IoProviders system="Cluster" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
- <IoProvider load_condition="0" module="PMA" name="PLC" map_module="PMA" class="MECF.Framework.RT.Core.IoProviders.MCProtocolPlc" assembly="MECF.Framework.RT.Core">
- <Parameter ip="127.0.0.1" port="6731" network_id="1" station_id="1"></Parameter>
- <Blocks>
- <Block type="di" offset="0" size="640" value_type=""></Block>
- <Block type="do" offset="0" size="640" value_type=""></Block>
- <Block type="ai" offset="0" size="640" value_type=""></Block>
- <Block type="ao" offset="0" size="640" value_type=""></Block>
- </Blocks>
- </IoProvider>
- <IoProvider load_condition="1" module="PMA" name="PLC" map_module="PMA" class="Venus_RT.Devices.FinsPlc" assembly="Venus_RT">
- <Parameter ip="192.168.10.11" port="9600"
- diBlockType="WR" doBlockType="WR" aiBlockType="D" aoBlockType="D"
- diStartPosition="20" doStartPosition="0" aiStartPosition="2000" aoStartPosition="1000" ></Parameter>
- <Blocks>
- <Block type="di" offset="0" size="128" value_type=""></Block>
- <Block type="do" offset="0" size="128" value_type=""></Block>
- <Block type="ai" offset="0" size="128" value_type=""></Block>
- <Block type="ao" offset="0" size="128" value_type=""></Block>
- </Blocks>
- </IoProvider>
- <IoProvider load_condition="0" module="PMB" name="PLC" map_module="PMB" class="MECF.Framework.RT.Core.IoProviders.MCProtocolPlc" assembly="MECF.Framework.RT.Core">
- <Parameter ip="127.0.0.1" port="6732" network_id="1" station_id="1"></Parameter>
- <Blocks>
- <Block type="di" offset="0" size="640" value_type=""></Block>
- <Block type="do" offset="0" size="640" value_type=""></Block>
- <Block type="ai" offset="0" size="640" value_type=""></Block>
- <Block type="ao" offset="0" size="640" value_type=""></Block>
- </Blocks>
- </IoProvider>
- <IoProvider load_condition="1" module="PMB" name="PLC" map_module="PMB" class="Venus_RT.Devices.FinsPlc" assembly="Venus_RT">
- <Parameter ip="192.168.10.12" port="9600"
- diBlockType="WR" doBlockType="WR" aiBlockType="D" aoBlockType="D"
- diStartPosition="20" doStartPosition="0" aiStartPosition="2000" aoStartPosition="1000" ></Parameter>
- <Blocks>
- <Block type="di" offset="0" size="128" value_type=""></Block>
- <Block type="do" offset="0" size="128" value_type=""></Block>
- <Block type="ai" offset="0" size="128" value_type=""></Block>
- <Block type="ao" offset="0" size="128" value_type=""></Block>
- </Blocks>
- </IoProvider>
- <IoProvider load_condition="0" module="PMC" name="PLC" map_module="PMC" class="MECF.Framework.RT.Core.IoProviders.MCProtocolPlc" assembly="MECF.Framework.RT.Core">
- <Parameter ip="127.0.0.1" port="6733" network_id="1" station_id="1"></Parameter>
- <Blocks>
- <Block type="di" offset="0" size="640" value_type=""></Block>
- <Block type="do" offset="0" size="640" value_type=""></Block>
- <Block type="ai" offset="0" size="640" value_type=""></Block>
- <Block type="ao" offset="0" size="640" value_type=""></Block>
- </Blocks>
- </IoProvider>
- <IoProvider load_condition="1" module="PMC" name="PLC" map_module="PMC" class="Venus_RT.Devices.FinsPlc" assembly="Venus_RT">
- <Parameter ip="192.168.10.13" port="9600"
- diBlockType="WR" doBlockType="WR" aiBlockType="D" aoBlockType="D"
- diStartPosition="20" doStartPosition="0" aiStartPosition="2000" aoStartPosition="1000" ></Parameter>
- <Blocks>
- <Block type="di" offset="0" size="128" value_type=""></Block>
- <Block type="do" offset="0" size="128" value_type=""></Block>
- <Block type="ai" offset="0" size="128" value_type=""></Block>
- <Block type="ao" offset="0" size="128" value_type=""></Block>
- </Blocks>
- </IoProvider>
-
- <IoProvider load_condition="0" module="TM" name="PLC" map_module="TM" map_file="_ioDefineVenus_MF.xml" class="MECF.Framework.RT.Core.IoProviders.MCProtocolPlc" assembly="MECF.Framework.RT.Core">
- <Parameter ip="127.0.0.1" port="6831" network_id="1" station_id="1"></Parameter>
- <Blocks>
- <Block type="di" offset="0" size="640" value_type=""></Block>
- <Block type="do" offset="0" size="640" value_type=""></Block>
- <Block type="ai" offset="0" size="640" value_type=""></Block>
- <Block type="ao" offset="0" size="640" value_type=""></Block>
- </Blocks>
- </IoProvider>
- <IoProvider load_condition="1" module="TM" name="PLC" map_module="TM" map_file="_ioDefineVenus_MF.xml" class="Venus_RT.Devices.FinsPlc" assembly="Venus_RT">
- <Parameter ip="192.168.10.210" port="9600"
- diBlockType="WR" doBlockType="WR" aiBlockType="D" aoBlockType="D"
- diStartPosition="20" doStartPosition="0" aiStartPosition="2000" aoStartPosition="1000" ></Parameter>
- <Blocks>
- <Block type="di" offset="0" size="128" value_type=""></Block>
- <Block type="do" offset="0" size="128" value_type=""></Block>
- <Block type="ai" offset="0" size="128" value_type=""></Block>
- <Block type="ao" offset="0" size="128" value_type=""></Block>
- </Blocks>
- </IoProvider>
- </IoProviders>
|