1234567891011121314151617181920212223242526272829303132333435363738394041424344454647484950515253545556575859606162636465666768697071727374757677787980818283848586878889909192939495 |
- using Aitex.Core.RT.Routine;
- using Aitex.Core.RT.SCCore;
- using Venus_RT.Devices;
- using MECF.Framework.Common.Routine;
- using Venus_Core;
- namespace Venus_RT.Modules.PMs
- {
- class LoadLockLeakCheckRoutine : PMRoutineBase, IRoutine
- {
- private enum LeakCheckStep
- {
- kPumpToBasePressure,
- kPumpingDelay,
- kLeakCheckDelay,
- kEnd,
- }
- public double LeakRate { get; private set; }
- private int _basePressureLL = 100;
- private int _leakcheckPumpTimeLL = 180;
- private int _leakcheckWaitTimeLL = 300;
- private double _startPressure = 0;
- private double _endPressure = 0;
- private double _leakRate = 30.0;
- public LoadLockLeakCheckRoutine(JetPM chamber) : base(chamber)
- {
- Name = "Loadlock Leakcheck";
- }
- public RState Start(params object[] objs)
- {
- if (CheckLidLoadLock() &&
- CheckSlitDoor() &&
- CheckDryPump())
- {
- Reset();
- _chamber.CloseValves();
- _basePressureLL = SC.GetValue<int>($"{Module}.Pump.LoadLockPumpBasePressure");
- _leakcheckPumpTimeLL = SC.GetValue<int>($"{Module}.Pump.LoadLockLeakCheckPumpTime");
- _leakcheckWaitTimeLL = SC.GetValue<int>($"{Module}.Pump.LoadLockLeakCheckPumpTime");
- _leakRate = SC.GetValue<double>($"{Module}.Pump.LoadLockLeakRate");
- return Runner.Start(Module, Name);
- }
- return RState.Failed;
- }
- public RState Monitor()
- {
- Runner.Run((int)LeakCheckStep.kPumpToBasePressure, HOFs.WrapAction(_chamber.OpenValve, ValveType.LoadlockPumping, true), () => { return _chamber.LoadlockPressure <= _basePressureLL; })
- .Delay((int)LeakCheckStep.kPumpingDelay, _leakcheckPumpTimeLL * 1000)
- .Run((int)LeakCheckStep.kLeakCheckDelay, StartLeakCheck, _leakcheckWaitTimeLL * 1000)
- .End((int)LeakCheckStep.kEnd, CalcLeakCheckResult, _delay_50ms);
- return Runner.Status;
- }
- public void Abort()
- {
- CloseAllValves();
- }
- bool StartLeakCheck()
- {
- _chamber.OpenValve(ValveType.LoadlockPumping, false);
- _startPressure = _chamber.LoadlockPressure;
- Notify($"LoadLock压力开始值 {_startPressure} mt");
- return true;
- }
- bool CalcLeakCheckResult()
- {
- _endPressure = _chamber.LoadlockPressure;
- LeakRate = (_endPressure - _startPressure) * 60.0 / _leakcheckWaitTimeLL;
- if(LeakRate < _leakRate)
- {
- Notify($"LoadLock Leakcheck完成, 压力结束值: {_startPressure} mt, 漏率:{LeakRate} mt/min");
- }
- else
- {
- Stop($"LoadLock Leakcheck失败, 腔体漏率 [{LeakRate}] mt/min, 高于 [{_leakRate}] mt/min");
- }
-
- return true;
- }
- }
- }
|