123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182183184185186187188189190191192193194195196197198199200201202203204205206207208209210211212213214215216217218219220221222223224225226227228229230231232233234235236237238239240241242243244245246247248249250251252253254255256257258259260261262263264265266267268269270271272273274275276277278279280281282283284285286287288289290291292293294295296297298299300301302303304305306307308309310311312313314315316317318319320321322323324325326327328329330331332333334335336337338339340341342343344345346347348349350351352353354355356357358359360361362363364365366367368369370371372373374375376377378379380381382383384385386387388389390391392393394395396397398399400401402403404405406407408409410411412413414415
  1. using System;
  2. using System.Collections.Generic;
  3. using System.Diagnostics;
  4. using Venus_RT.Modules;
  5. using MECF.Framework.Common.Communications;
  6. using MECF.Framework.Common.Equipment;
  7. using Venus_Core;
  8. using Aitex.Core.RT.SCCore;
  9. using Aitex.Core.RT.Event;
  10. using Aitex.Core.RT.Device;
  11. using Aitex.Core.RT.Log;
  12. namespace Venus_RT.Devices
  13. {
  14. class PendulumValve : IDevice
  15. {
  16. public enum Operation
  17. {
  18. SetPosition,
  19. GetPositionSP,
  20. Hold,
  21. OpenValve,
  22. CloseValve,
  23. SetPressure,
  24. GetPressureSP,
  25. GetAssembly,
  26. GetPosition,
  27. GetPressure,
  28. GetSensor1Data,
  29. GetSensor2Data,
  30. GetPressureCtrlStatus,
  31. GetDeviceStatus,
  32. GetWarnings,
  33. GetSensorOffset,
  34. GetSensor1Offset,
  35. GetSensor2Offset,
  36. GetLearnStatus,
  37. GetLearnPressureLimit,
  38. GetErrorStatus,
  39. GetFatalErrorStatus,
  40. GetThrottleCycleCounter,
  41. GetIsolationCycleCounter,
  42. GetPowerUpCounter,
  43. GetHardwareConfiguration,
  44. GetFirmwareConfiguration,
  45. GetIdentification,
  46. SetAccessMode,
  47. SetInterfaceConfiguration,
  48. SetValveConfiguration,
  49. SetSensorConfiguration,
  50. SetRangeConfiguration,
  51. SetZero,
  52. SetPressureAlignment,
  53. SetLearn,
  54. DownloadLearnData,
  55. UploadLearnData,
  56. SetPIDConfiguration,
  57. GetPIDConfiguration,
  58. SetValveSpeed,
  59. GetValveSpeed,
  60. Reset,
  61. Invalid,
  62. }
  63. private readonly Dictionary<Operation, string> _noneParaCommandOp = new Dictionary<Operation, string>
  64. {
  65. {Operation.GetPositionSP, "i:38" },
  66. {Operation.Hold, "H:" },
  67. {Operation.CloseValve, "C:" },
  68. {Operation.OpenValve, "O:" },
  69. {Operation.GetPressureSP, "i:38" },
  70. {Operation.GetAssembly, "i:76" },
  71. {Operation.GetPosition, "A:" },
  72. {Operation.GetPressure, "P:" },
  73. {Operation.GetSensor1Data, "i:64" },
  74. {Operation.GetSensor2Data, "i:65" },
  75. {Operation.GetPressureCtrlStatus, "i:36" },
  76. {Operation.GetDeviceStatus, "i:30" },
  77. {Operation.GetWarnings, "i:35" },
  78. {Operation.GetSensorOffset, "i:62" },
  79. {Operation.GetSensor1Offset, "i:60" },
  80. {Operation.GetSensor2Offset, "i:61" },
  81. {Operation.GetLearnStatus, "i:32" },
  82. {Operation.GetLearnPressureLimit, "i:34" },
  83. {Operation.GetErrorStatus, "i:52" },
  84. {Operation.GetFatalErrorStatus, "i:50" },
  85. {Operation.GetThrottleCycleCounter, "i:70" },
  86. {Operation.GetIsolationCycleCounter, "i:71" },
  87. {Operation.GetPowerUpCounter, "i:72" },
  88. {Operation.GetHardwareConfiguration, "i:80" },
  89. {Operation.GetFirmwareConfiguration, "i:82" },
  90. {Operation.GetIdentification, "i:83" },
  91. };
  92. private readonly Dictionary<Operation, string> _singleParaCommandOp = new Dictionary<Operation, string>
  93. {
  94. {Operation.SetPosition, "R:{0:D6}" },
  95. {Operation.SetPressure, "S:{0:D8}" },
  96. {Operation.SetAccessMode, "c:01{0:D2}" },
  97. {Operation.SetInterfaceConfiguration, "s:20{0:D8}" },
  98. {Operation.SetValveConfiguration, "s:04{0:D2}000000" },
  99. {Operation.SetSensorConfiguration, "s:01{0:D8}" },
  100. {Operation.SetRangeConfiguration, "s:21{0:D8}" },
  101. {Operation.SetPressureAlignment, "c:6002{0:D8}" },
  102. {Operation.SetLearn, "L:{0:D8}" },
  103. {Operation.UploadLearnData, "u:{0:D3}" },
  104. {Operation.SetPIDConfiguration, "s:02{0:D8}" },
  105. {Operation.SetValveSpeed, "V:00{0:D4}" }
  106. };
  107. private readonly Dictionary<Operation, string> _twoParaCommandOp = new Dictionary<Operation, string>
  108. {
  109. {Operation.DownloadLearnData, "d:{0:D3}{1:D8}" }
  110. };
  111. private readonly Dictionary<string, string> _deviceError = new Dictionary<string, string>
  112. {
  113. {"000001", "Parity error" },
  114. {"000002", "Input buffer overflow (to many characters) " },
  115. {"000003", "Framing error (data length, number of stop bits)" },
  116. {"000010", "<CR> or <LF> missing" },
  117. {"000011", ": missing" },
  118. {"000012", "Invalid number of characters (between : and [CR][LF])" },
  119. {"000020", "Unknown command" },
  120. {"000021", "Unknown command" },
  121. {"000022", "Invalid value" },
  122. {"000023", "Invalid value" },
  123. {"000030", "Value out of range" },
  124. {"000041", "Command not applicable for hardware configuration" },
  125. {"000060", "ZERO disabled" },
  126. {"000080", "Command not accepted due to local operation" },
  127. {"000082", "Command not accepted due to synchronization, CLOSED or OPEN by digital input, safety mode or fatal error" },
  128. };
  129. public string Module { get; set; }
  130. public string Name { get; set; }
  131. public int Pressure { get; private set; }
  132. public int Position { get; private set; }
  133. public string Status { get; private set; }
  134. public bool IsOpen { get; private set; }
  135. private readonly string EOF = "\r\n";
  136. private readonly int _readInterval = 500;
  137. private int _queryFlag = 0;
  138. private readonly AsyncSerialPort _serial;
  139. private Stopwatch _queryWatch = new Stopwatch();
  140. private string _lastAlarmString = string.Empty;
  141. private Operation[] _querys = new Operation[] { Operation.GetPressure, Operation.GetPosition, Operation.GetDeviceStatus };
  142. public PendulumValve(ModuleName mod)
  143. {
  144. Name = VenusDevice.PendulumValve.ToString();
  145. Module = mod.ToString();
  146. var _PortNum = SC.GetStringValue($"{mod}.PendulumValve.Port");
  147. _serial = new AsyncSerialPort(_PortNum, 9600, 7, System.IO.Ports.Parity.Even, System.IO.Ports.StopBits.One, EOF);
  148. IsOpen = false;
  149. }
  150. public bool Initialize()
  151. {
  152. if (!_serial.Open())
  153. {
  154. _noRepeatAlarm("Pendulum Valve 串口无法打开");
  155. return false;
  156. }
  157. _serial.OnDataChanged += OnPortDataChanged;
  158. _serial.OnErrorHappened += OnErrorOccurred;
  159. _queryWatch.Restart();
  160. return true;
  161. }
  162. public void Monitor()
  163. {
  164. if(_queryWatch.ElapsedMilliseconds > _readInterval)
  165. {
  166. SendCommand(_querys[_queryFlag++ % 3]);
  167. _queryWatch.Restart();
  168. }
  169. }
  170. public void Reset()
  171. {
  172. }
  173. public void Terminate()
  174. {
  175. _serial?.Close();
  176. }
  177. private void OnErrorOccurred(string obj)
  178. {
  179. _noRepeatAlarm($"[{Module}] VAT Pendulum Valve error: [{obj}]");
  180. }
  181. private void OnPortDataChanged(string obj)
  182. {
  183. if (string.IsNullOrEmpty(obj))
  184. {
  185. _noRepeatAlarm("VAT Pendulum Valve receive empty message");
  186. return;
  187. }
  188. try
  189. {
  190. var data = obj.TrimEnd().Split(':');
  191. switch(data[0])
  192. {
  193. case "P":
  194. {
  195. int pressure;
  196. if (int.TryParse(data[1], out pressure))
  197. Pressure = pressure;
  198. }
  199. break;
  200. case "A":
  201. {
  202. int position;
  203. if (int.TryParse(data[1], out position))
  204. Position = position;
  205. }
  206. break;
  207. case "i":
  208. {
  209. _tryParseInqueryData(obj);
  210. }
  211. break;
  212. case "C":
  213. case "O":
  214. case "H":
  215. case "S":
  216. break;
  217. case "E":
  218. {
  219. _noRepeatAlarm($"[{Module}] VAT Pendulum Valve device error: {_deviceError[data[1]]}");
  220. }
  221. break;
  222. default:
  223. {
  224. _noRepeatAlarm($"VAT Pendulum Valve: unrecognized received data: {obj}");
  225. break;
  226. }
  227. }
  228. }
  229. catch (Exception ex)
  230. {
  231. _noRepeatAlarm($"[{Module}] VAT Pendulum Valve error: [{ex.Message}], Data: {obj}");
  232. }
  233. }
  234. private bool SendCommand(Operation op)
  235. {
  236. if(_noneParaCommandOp.ContainsKey(op))
  237. {
  238. return _serial.Write(_noneParaCommandOp[op] + EOF);
  239. }
  240. else
  241. {
  242. return false;
  243. }
  244. }
  245. private bool SendCommand(Operation op, int data)
  246. {
  247. if(_singleParaCommandOp.ContainsKey(op))
  248. {
  249. var cmd = string.Format(_singleParaCommandOp[op], data) + EOF;
  250. return _sendCmd(cmd);
  251. }
  252. else
  253. {
  254. _noRepeatAlarm("This VAT Pendulum Valve command need 1 data");
  255. return false;
  256. }
  257. }
  258. private bool _sendCmd(string cmd)
  259. {
  260. return _serial.Write(cmd);
  261. }
  262. private void _noRepeatAlarm(string alarm)
  263. {
  264. if (_lastAlarmString != alarm)
  265. {
  266. _lastAlarmString = alarm;
  267. LOG.Write(eEvent.ERR_PENDULUM_VALVE, ModuleHelper.Converter(Module), alarm);
  268. EV.PostAlarmLog(Module, alarm);
  269. }
  270. }
  271. private bool _tryParseInqueryData(string data)
  272. {
  273. var cmdPrix = data.Substring(0, 4);
  274. Operation oper = Operation.Invalid;
  275. foreach( var item in _noneParaCommandOp)
  276. {
  277. if(item.Value == cmdPrix)
  278. {
  279. oper = item.Key;
  280. break;
  281. }
  282. }
  283. if( oper == Operation.Invalid)
  284. {
  285. return false;
  286. }
  287. switch(oper)
  288. {
  289. case Operation.GetDeviceStatus:
  290. {
  291. Status = data.Substring(4, 8);
  292. if(Status[1] == 'E')
  293. {
  294. // Fatal Error
  295. _noRepeatAlarm($"Device Status error:{Status}");
  296. }
  297. else if(Status[3] == '1')
  298. {
  299. // Warning Present
  300. _noRepeatAlarm($"Device Warning Present:{Status}");
  301. }
  302. }
  303. break;
  304. default:
  305. break;
  306. }
  307. return true;
  308. }
  309. public bool SetPosition(int postion)
  310. {
  311. if(_CheckStatus())
  312. {
  313. IsOpen = postion > 0;
  314. return SendCommand(Operation.SetPosition, postion);
  315. }
  316. return false;
  317. }
  318. public bool SetPressure(int pressure)
  319. {
  320. if(_CheckStatus())
  321. {
  322. IsOpen = true;
  323. return SendCommand(Operation.SetPressure, pressure);
  324. }
  325. return false;
  326. }
  327. public bool Hold()
  328. {
  329. return SendCommand(Operation.Hold);
  330. }
  331. public bool TurnValve(bool on)
  332. {
  333. if(_CheckStatus(on))
  334. {
  335. IsOpen = on;
  336. return SendCommand(on ? Operation.OpenValve : Operation.CloseValve);
  337. }
  338. return false;
  339. }
  340. bool _CheckStatus(bool bTurnOn = false)
  341. {
  342. if (Status != null && Status[1] == 'E')
  343. {
  344. _noRepeatAlarm($"PendulumValve is error status, can do turn on/off operation.");
  345. return false;
  346. }
  347. var _chamber = DEVICE.GetDevice<JetPM>(Module);
  348. if (bTurnOn && !_chamber.IsTurboPumpAtSpeed)
  349. {
  350. _noRepeatAlarm($"Turbo Pump not at speed, can not turn on pendulum valve.");
  351. return false;
  352. }
  353. if (_chamber.ForelinePressure > 500)
  354. {
  355. _noRepeatAlarm($"Foreline Pressure:{_chamber.ForelinePressure} is too high, can not turn on pendulum valve.");
  356. return false;
  357. }
  358. return true;
  359. }