| 123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384 | 
							- using Aitex.Core.RT.DataCenter;
 
- using Aitex.Core.RT.Device;
 
- using Aitex.Core.RT.Log;
 
- using System;
 
- using Venus_RT.Devices.IODevices;
 
- using System.Collections.Generic;
 
- using System.Linq;
 
- using System.Text;
 
- using System.Threading.Tasks;
 
- using Aitex.Core.RT.Tolerance;
 
- using Aitex.Core.Util;
 
- using Aitex.Core.RT.IOCore;
 
- using System.Xml;
 
- namespace Venus_RT.Devices
 
- {
 
-      class IoTMSEPressureCtl:BaseDevice,IDevice
 
-     {
 
-         public readonly IoPressureMeter TMVacuumGauge;
 
-         public readonly IoPressureMeter TMPipelineGauge;
 
-         public readonly IoPressureMeter VCEVacuumGauge;
 
-         public readonly IoPressureMeter VCEPipelineVacuumGauge;
 
-         private readonly ToleranceChecker _tolerance = new ToleranceChecker();
 
-         private readonly R_TRIG _trigTMVacuumGauge = new R_TRIG();
 
-         private readonly R_TRIG _trigTMPipelineGauge = new R_TRIG();
 
-         private readonly R_TRIG _trigVCEVacuumGauge = new R_TRIG();
 
-         private readonly R_TRIG _trigVCEPipelineVacuumGauge = new R_TRIG();
 
-         public double TargetPressure { get; set; }
 
-         public IoTMSEPressureCtl(string module, XmlElement node, string ioModule = "")
 
-         {
 
-             base.Module = module;
 
-             base.Name = node.GetAttribute("id");
 
-             base.Display = node.GetAttribute("display");
 
-             base.DeviceID = node.GetAttribute("schematicId");
 
-             TMVacuumGauge = ParseDeviceNode<IoPressureMeter>(Module, "MFPressureMeter", node);
 
-             TMPipelineGauge = ParseDeviceNode<IoPressureMeter>(Module, "MFForelineMeter", node);
 
-             VCEVacuumGauge = ParseDeviceNode<IoPressureMeter>(Module, "VCEPressureMeter", node);
 
-             VCEPipelineVacuumGauge = ParseDeviceNode<IoPressureMeter>(Module, "VCEPipelineMeter", node);
 
-         }
 
-         public bool Initialize()
 
-         {
 
-             return true;
 
-         }
 
-         public void SetTMPressure(float pressure)
 
-         {
 
-         }
 
-         public void Terminate()
 
-         {
 
-         }
 
-         public void Monitor()
 
-         {
 
-    
 
-                 _trigTMVacuumGauge.CLK = TMVacuumGauge.GaugeAlarm;
 
-                 if (_trigTMVacuumGauge.Q) LOG.Write(eEvent.ERR_DEVICE_INFO, Module, "MF pressure gauge Alarm");
 
-             
 
-                 _trigTMPipelineGauge.CLK = TMPipelineGauge.GaugeAlarm;
 
-                 if (_trigTMPipelineGauge.Q) LOG.Write(eEvent.ERR_DEVICE_INFO, Module, "MF Pipeline pressure gauge Alarm");
 
-             
 
-                 _trigVCEVacuumGauge.CLK = VCEVacuumGauge.GaugeAlarm;
 
-                 if (_trigVCEVacuumGauge.Q) LOG.Write(eEvent.ERR_DEVICE_INFO, Module, "VCE pressure gauge Alarm");
 
-             
 
-                 _trigVCEPipelineVacuumGauge.CLK = VCEPipelineVacuumGauge.GaugeAlarm;
 
-                 if (_trigVCEPipelineVacuumGauge.Q) LOG.Write(eEvent.ERR_DEVICE_INFO, Module, "VCE Pipeline pressure Gauge Alarm");
 
-             
 
-         }
 
-         public void Reset()
 
-         {
 
-             _trigTMVacuumGauge.RST = true;
 
-             _trigTMPipelineGauge.RST = true;
 
-             _trigVCEVacuumGauge.RST = true;
 
-             _trigVCEPipelineVacuumGauge.RST = true;
 
-         }
 
-     }
 
- }
 
 
  |