| 123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182183184185186187188189190191192193194195196197198199200201202203204205206207208209210211212213214215216217218219220221222223224225226227228229230231232233234235236237238239240241242243244245246247248249250251252253254255256257258259260261262263264265266267268269270271272273274275276277278279280281282283284285286287288289290291292293294295296297298299300301302303304305306307308309310311312313314315316317318319320321322323324325326327328329330331332333334335336 | <?xml version="1.0" encoding="utf-16"?><DeviceModelDefine type="Kepler2300" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">  <IoValves>	<IoValve id="ValvePVN21" display="PVN21 Valve" schematicId="PVN21" unit="" isNc="true"	        isDefaultOpen="false" diOpen="" doOpen="DO_PVN21" diCloseSensor="" diOpenSensor="" />	<IoValve id="ValvePVN22" display="PVN22 Valve" schematicId="PVN22" unit="" isNc="true"			isDefaultOpen="false" diOpen="" doOpen="DO_PVN22" diCloseSensor="" diOpenSensor="" />	<IoValve id="ValvePV11" display="PV11 Valve" schematicId="PV11" unit="" isNc="true"			isDefaultOpen="false" diOpen="" doOpen="DO_PV11" diCloseSensor="" diOpenSensor="" />	<IoValve id="ValvePV12" display="PV12 Valve" schematicId="PV12" unit="" isNc="true"			isDefaultOpen="false" diOpen="" doOpen="DO_PV12" diCloseSensor="" diOpenSensor="" />	<IoValve id="ValvePV21" display="PV21 Valve" schematicId="PV21" unit="" isNc="true"			isDefaultOpen="false" diOpen="" doOpen="DO_PV21" diCloseSensor="" diOpenSensor="" />	<IoValve id="ValvePV22" display="PV22 Valve" schematicId="PV22" unit="" isNc="true"			isDefaultOpen="false" diOpen="" doOpen="DO_PV22" diCloseSensor="" diOpenSensor="" />	<IoValve id="ValvePV31" display="PV31 Valve" schematicId="PV31" unit="" isNc="true"			isDefaultOpen="false" diOpen="" doOpen="DO_PV31" diCloseSensor="" diOpenSensor="" />	<IoValve id="ValvePV32" display="PV32 Valve" schematicId="PV32" unit="" isNc="true"			isDefaultOpen="false" diOpen="" doOpen="DO_PV32" diCloseSensor="" diOpenSensor="" />	<IoValve id="ValvePV41" display="PV41 Valve" schematicId="PV41" unit="" isNc="true"            isDefaultOpen="false" diOpen="" doOpen="DO_PV41" diCloseSensor="" diOpenSensor="" />	<IoValve id="ValvePV42" display="PV42 Valve" schematicId="PV42" unit="" isNc="true"			isDefaultOpen="false" diOpen="" doOpen="DO_PV42" diCloseSensor="" diOpenSensor="" />	<IoValve id="ValveN2" display="N2 valve" schematicId=""            unit="" isNc="true" isDefaultOpen="false" diOpen="" doOpen="DO_N2_Valve" diCloseSensor="" diOpenSensor="" />	<IoValve id="ValvePVHe1" display="PVHe1 valve" schematicId=""			unit="" isNc="true" isDefaultOpen="false" diOpen="" doOpen="DO_PVHe1"			diCloseSensor="" diOpenSensor="" />	<IoValve id="ValvePVHe2" display="PVHe2 valve" schematicId=""			unit="" isNc="true" isDefaultOpen="false" diOpen="" doOpen="DO_PVHe2"			diCloseSensor="" diOpenSensor="" />	<IoValve id="ValveGasFinal" display="Gas Final valve" schematicId=""			unit="" isNc="true" isDefaultOpen="false" diOpen="" doOpen="DO_Gas_Final_Valve"			diCloseSensor="" diOpenSensor="" />	<IoValve id="ValveSoftPump" display="Soft Pump valve" schematicId=""			unit="" isNc="true" isDefaultOpen="false" diOpen="" doOpen="DO_Soft_Pumping_Valve"			diCloseSensor="" diOpenSensor="" />	<IoValve id="ValveFastPump" display="FastPump valve" schematicId=""        unit="" isNc="true" isDefaultOpen="false" diOpen="" doOpen="DO_Fast_Pumping_Valve" diCloseSensor="" diOpenSensor="" />	  <IoValve id="ValveTurboPumpPumping" display="Turbo Pump Pumping valve" schematicId=""			unit="" isNc="true" isDefaultOpen="false" diOpen="" doOpen="DO_Turbo_Pump_Pumping_Valve"			diCloseSensor="" diOpenSensor="" />	<IoValve id="ValveTurboPumpPurge" display="Turbo Pump Purge valve" schematicId=""			unit="" isNc="true" isDefaultOpen="false" diOpen="" doOpen="DO_Turbo_Pump_Purge_Valve"			diCloseSensor="" diOpenSensor="" />	<IoValve id="ValveGuage" display="Guage valve" schematicId=""			unit="" isNc="true" isDefaultOpen="false" diOpen="" doOpen="DO_Guage_Valve"			diCloseSensor="" diOpenSensor="" />	      <IoValve id="ValveMfc1" display="MFC1 Valve" schematicId="PV1" unit="" isNc="true"            isDefaultOpen="false" diOpen="" doOpen="DO_MFC1_Valve" diCloseSensor="" diOpenSensor="" />    <IoValve id="ValveMfc2" display="MFC2 Valve" schematicId="PV2" unit="" isNc="true"            isDefaultOpen="false" diOpen="" doOpen="DO_MFC2_Valve" diCloseSensor="" diOpenSensor="" />    <IoValve id="ValveMfc3" display="MFC3 Valve" schematicId="PV3" unit="" isNc="true"            isDefaultOpen="false" diOpen="" doOpen="DO_MFC3_Valve" diCloseSensor="" diOpenSensor="" />    <IoValve id="ValveMfc4" display="MFC4 Valve" schematicId="PV4" unit="" isNc="true"            isDefaultOpen="false" diOpen="" doOpen="DO_MFC4_Valve" diCloseSensor="" diOpenSensor="" />    <IoValve id="ValveMfc5" display="MFC5 Valve" schematicId="PV5" unit="" isNc="true"            isDefaultOpen="false" diOpen="" doOpen="DO_MFC5_Valve" diCloseSensor="" diOpenSensor="" />    <IoValve id="ValveMfc6" display="MFC6 Valve" schematicId="PV6" unit="" isNc="true"            isDefaultOpen="false" diOpen="" doOpen="DO_MFC6_Valve" diCloseSensor="" diOpenSensor="" />    <IoValve id="ValveMfc7" display="MFC7 Valve" schematicId="PV7" unit="" isNc="true"		    isDefaultOpen="false" diOpen="" doOpen="DO_MFC7_Valve" diCloseSensor="" diOpenSensor="" />    <IoValve id="ValveMfc8" display="MFC8 Valve" schematicId="PV8" unit="" isNc="true"		    isDefaultOpen="false" diOpen="" doOpen="DO_MFC8_Valve" diCloseSensor="" diOpenSensor="" />      </IoValves>  <IoMfcs assembly="Venus_RT" classType="Venus_RT.Devices.IODevices.IoMfc">    <IoMfc id="MfcGas1" display="Gas1" schematicId="MFC1" unit="sccm"           aiFlow="AI_MFC1_Flow" aoFlow="AO_MFC1_Flow_Setpoint" diOffline="" aoRange=""           diPressureAlarm="DI_MFC1_Pressure_SW"/>    <IoMfc id="MfcGas2" display="Gas2" schematicId="MFC2" unit="sccm"           aiFlow="AI_MFC2_Flow" aoFlow="AO_MFC2_Flow_Setpoint" diOffline="" aoRange=""           diPressureAlarm="DI_MFC2_Pressure_SW"/>    <IoMfc id="MfcGas3" display="Gas3" schematicId="MFC3" unit="sccm"           aiFlow="AI_MFC3_Flow" aoFlow="AO_MFC3_Flow_Setpoint" diOffline="" aoRange=""           diPressureAlarm="DI_MFC3_Pressure_SW"/>    <IoMfc id="MfcGas4" display="Gas4" schematicId="MFC4" unit="sccm"          aiFlow="AI_MFC4_Flow" aoFlow="AO_MFC4_Flow_Setpoint" diOffline="" aoRange=""          diPressureAlarm="DI_MFC4_Pressure_SW"/>    <IoMfc id="MfcGas5" display="Gas5" schematicId="MFC5" unit="sccm"           aiFlow="AI_MFC5_Flow" aoFlow="AO_MFC5_Flow_Setpoint" diOffline="" aoRange=""           diPressureAlarm="DI_MFC5_Pressure_SW"/>	<IoMfc id="MfcGas6" display="Gas6" schematicId="MFC6" unit="sccm"        aiFlow="AI_MFC6_Flow" aoFlow="AO_MFC6_Flow_Setpoint" diOffline="" aoRange=""        diPressureAlarm="DI_MFC6_Pressure_SW"/>	<IoMfc id="MfcGas7" display="Gas7" schematicId="MFC7" unit="sccm"		aiFlow="AI_MFC7_Flow" aoFlow="AO_MFC7_Flow_Setpoint" diOffline="" aoRange=""		diPressureAlarm="DI_MFC7_Pressure_SW"/>	<IoMfc id="MfcGas8" display="Gas8" schematicId="MFC8" unit="sccm"		aiFlow="AI_MFC8_Flow" aoFlow="AO_MFC8_Flow_Setpoint" diOffline="" aoRange=""		diPressureAlarm="DI_MFC8_Pressure_SW"/>	<IoMfc id="MfcN2" display="N2" schematicId="N2" unit="sccm"	    aiFlow="AI_Turbo_Pump_N2_Flow" aoFlow="AO_Turbo_Pump_N2_Flow_Setpoint" diOffline="" aoRange=""	    diPressureAlarm="DI_PN2_Pressure_SW"/>	<IoMfc id="MfcHe" display="He" schematicId="He" unit="sccm"		aiFlow="AI_He_Flow" aoFlow="AO_He_Flow_Setpoint" diOffline="" aoRange=""		diPressureAlarm="DI_He_Pressure_SW"/>  </IoMfcs>  <IoGasSticks assembly="Venus_RT" classType="Venus_RT.Devices.IoGasStick">    <IoGasStick id="GasStick1" display="" mfc ="MfcGas1" downvalve="ValveMfc1" />    <IoGasStick id="GasStick2" display="" mfc ="MfcGas2" downvalve="ValveMfc2" />    <IoGasStick id="GasStick3" display="" mfc ="MfcGas3" downvalve="ValveMfc3" />    <IoGasStick id="GasStick4" display="" mfc ="MfcGas4" downvalve="ValveMfc4" />    <IoGasStick id="GasStick5" display="" mfc ="MfcGas5" downvalve="ValveMfc5" />	<IoGasStick id="GasStick6" display="" mfc ="MfcGas6" downvalve="ValveMfc6" />	<IoGasStick id="GasStick7" display="" mfc ="MfcGas7" downvalve="ValveMfc7" />	<IoGasStick id="GasStick8" display="" mfc ="MfcGas8" downvalve="ValveMfc8" />	<IoGasStick id="GasStickN2" display="" mfc ="MfcN2" downvalve="ValveTurboPumpPurge" />  </IoGasSticks>	  <IoBacksideHes assembly="Venus_RT" classType="Venus_RT.Devices.IoBacksideHe">	    <IoBacksideHe id="BacksideHelium" display="" mfc="" downvalve="ValvePVHe1" aoControlMode="AO_ESC_He_Control_Mode" aoPressureSP="AO_ESC_He_Pressure_Setpoint" />  </IoBacksideHes>  <IoSensors>    <IoSensor id="SensorATMSwitch" display="ATM Switch"  schematicId="" unit="" di="DI_ATM_Switch" isLowAsNormal="" textOutTrigValue="true" infoText="" warningText="" alarmText="" />	  <IoSensor id="SensorPMLidClosed" display="PM Lid Closed"  schematicId="" unit="" di="DI_Lid_Closed" isLowAsNormal="" textOutTrigValue="false"				infoText="" warningText="" alarmText="" />	  <IoSensor id="SensorLoadlockATMSwitch" display="Loadlock ATM Switch"  schematicId="" unit="" di="DI_Loadlock_ATM_SW" isLowAsNormal="" textOutTrigValue="true"				infoText="" warningText="" alarmText="" />	  <IoSensor id="SensorVacSwitch" display="VAC Switch"  schematicId="" unit="" di="DI_VAC_Switch" isLowAsNormal="" textOutTrigValue="true"				infoText="" warningText="" alarmText="" />	  <IoSensor id="SensorWaterLeakOk" display="Water Leak Ok"  schematicId="" unit="" di="DI_Water_Leak_Sensor" isLowAsNormal="" textOutTrigValue="false"				infoText="" warningText="Sensor water leak" alarmText="" />	  <IoSensor id="SensorCDAPressureOk" display="CDA pressure OK"  schematicId="" unit="" di="DI_CDA_Pressure_Switch" isLowAsNormal="" textOutTrigValue="false"				infoText="" warningText="Sensor CDA pressure abnormal" alarmText="" />	  <IoSensor id="N2PressureOk" display="N2 Pressure OK"  schematicId="" unit="" di="DI_PN2_Pressure_Switch" isLowAsNormal="" textOutTrigValue="false"			 infoText="" warningText="N2 Pressure Alarm" alarmText="" />	  <IoSensor id="GeneratorInterlock" display="RFG hardware interlock"  schematicId="" unit="" di="DI_Source_RF_Generator_Interlock" isLowAsNormal="" textOutTrigValue="false" infoText="Generator interlock" warningText="" alarmText="" />	  <IoSensor id="SensorSourceRFFan" display="Source RF Fan"  schematicId="" unit="" di="DI_Source_RF_Fan" isLowAsNormal="" textOutTrigValue="true" infoText="Source RF Fan" warningText="" alarmText="Source RF Fan Alarm" />	  <IoSensor id="SensorSlitDoorClosed" display="Slit Door Closed"  schematicId="" unit="" di="DI_Slit_Door_Close_POS" isLowAsNormal="" textOutTrigValue="false" infoText="" warningText="" alarmText="" />	  <IoSensor id="TurboPumpInterlock" display="Turbo Pump Interlock"  schematicId="" unit="" di="DI_Turbo_Pump_Interlock" isLowAsNormal="" textOutTrigValue="false" infoText="" warningText="" alarmText="" />	  <IoSensor id="GasBoxDoorSW" display="Gas Box Door SW"  schematicId="" unit="" di="DI_Gas_Box_Door_Switch" isLowAsNormal="" textOutTrigValue="false" infoText="" warningText="" alarmText="Gas Box Door SW Alarm" />	  <IoSensor id="GasBoxPressureSW" display="Gas Box Pressure SW"  schematicId="" unit="" di="DI_Gas_Box_Pressure_Switch" isLowAsNormal="" textOutTrigValue="false" infoText="" warningText="" alarmText="Gas Box Pressure Alarm" />	  	  <IoSensor id="CHBWallOTSWAlarm" display="CHB Wall OT SW Alarm"  schematicId="" unit="" di="DI_CHB_Wall_OT_SW_Alarm" isLowAsNormal="" textOutTrigValue="true" infoText="" warningText="" alarmText="CHB Wall OT SW Alarm" />	  <IoSensor id="SensorSmallWaferInPos" display="Small Wafer in Pos"  schematicId="" unit="" di="DI_Small_Wafer_In_POS" isLowAsNormal="" textOutTrigValue="true"              infoText="" warningText="" alarmText="" />  </IoSensors>  <IoPressureMeters assembly="Venus_RT" classType="Venus_RT.Devices.IODevices.IoPressureMeter">		<IoPressureMeter id="ProcessGauge" display="Process Pressure" schematicId="" unit="mTorr"						    aiValue="AI_Process_Pressure_100mt" diGaugeFail="" scPrecision="" scOffset=""/>	  <IoPressureMeter id="PressureGauge" display="Chamber Pressure" schematicId="" unit="mTorr"						    aiValue="AI_Chamber_Pressure_10t"						    diGaugeFail=""						    scPrecision="ChamberPressureGaugePrecision"						    scOffset=""/>		<IoPressureMeter id="ForelineGauge" display="Foreline Pressure" schematicId="" unit="mTorr"						    aiValue="AI_Foreline_Pressure_10t" diGaugeFail="DI_Chamber_Pressure_760t_Gauge_Alarm" scPrecision="" scOffset=""/>		<IoPressureMeter id="ESCHeGauge" display="ESC He Pressure" schematicId="" unit="mTorr"						    aiValue="AI_ESC_He_Pressure_100t" diGaugeFail="DI_ESC_He_Pressure_100t_Gauge_Alarm" scPrecision="" scOffset=""/>				<IoPressureMeter id="ProcessPressureHigh" display="ProcessPressureHigh" schematicId="" unit="mTorr"						    aiValue="AI_Chamber_Pressure_10t" diGaugeFail="" scPrecision="" scOffset=""/>		<IoPressureMeter id="ProcessPressureLow" display="ProcessPressureLow" schematicId="" unit="mTorr"						    aiValue="AI_Process_Pressure_100mt" diGaugeFail="" scPrecision="" scOffset=""/>	</IoPressureMeters>	  <IoPumps assembly="Venus_RT" classType="Venus_RT.Devices.IoPump" IsEnabled = "False">    <IoPump id="MainPump" display="Main Pump" schematicId="MainPump" unit="mTorr"            diBreakerState=""            diRunning="DI_Pump_Running"            diStart=""            diStop=""            diAlarm="DI_Pump_Alarm"            diWarning="DI_Pump_Warning"            diPumpTempAlarm=""            diN2Alarm="DI_Pump_N2_Purge_Alarm"            diWaterFlowAlarm="DI_Pump_Cool_Water_Flow_Alarm"            diExhaustPressureAlarm="DI_Pump_Exhaust_Pressure_Alarm"            doStart="DO_Pump_Start"            doStop="DO_Pump_Stop"            doWaterFlowAlarm=""            doN2PressureAlarm=""            aiWaterFlow=""            aiN2Pressure=""            aoN2PressureAlarmMaxValue=""            aoN2PressureAlarmMinValue=""            aoWaterFlowAlarmMaxValue=""            aoWaterFlowAlarmMinValue=""            scEnableDryPump="EnableDryPump"            scEnableWaterFlow="PumpEnableWaterFlow"            scWaterFlowMinValue="PumpWaterFlowMinValue"            scWaterFlowMaxValue="PumpWaterFlowMaxValue"            scWaterFlowOutOfToleranceWarningTime="PumpWaterFlowOutOfToleranceWarningTime"            scWaterFlowOutOfToleranceAlarmTime="PumpWaterFlowOutOfToleranceAlarmTime"            scEnableN2Pressure="PumpEnableN2Pressure"            scN2PressureMinValue="PumpN2PressureMinValue"            scN2PressureMaxValue="PumpN2PressureMaxValue"            scN2PressureOutOfToleranceWarningTime="PumpN2PressureOutOfToleranceWarningTime"            scN2PressureOutOfToleranceAlarmTime="PumpN2PressureOutOfToleranceAlarmTime" />  </IoPumps>  <IoPressureControls assembly="Venus_RT" classType="Venus_RT.Devices.IoPressureControl">    <IoPressureControl id="PressureControl" display="PressureControl" schematicId="PressureControl" unit="mTorr"                       diLogicProcessGasFlowing=""                       scGasFlowPressureAlarmRange="GasFlowPressureAlarmRange"                       scGasFlowPressureAlarmTime="GasFlowPressureAlarmTime"                       scIsIndependentControl="IsIndependentControl"                       scIsBoostPumpInstalled="EnableBoosterPump"                       scTvInstalled="EnableThrottleValve"                       boost="" tv="ThrottleValve" drypump="MainPump"                       pressureMeter ="PressureGauge" 					   processMeter="ProcessGauge" 					   forelineMeter="ForelineGauge" 					   loadlockMeter="LoadlockGauge" 					   escHeGauge="ESCHeGauge" 					   processPressureHigh="ProcessPressureHigh" 					   processPressureLow="ProcessPressureLow"					   tmPressureSetPoint="AO_TM_Chamber_Pressure"/>  </IoPressureControls>  <IoHeaters assembly="Venus_RT" classType="Venus_RT.Devices.IoHeater">    <IoHeater id="ValveHeater" display="Valve Heater" schematicId="" unit="℃"           doPowerOn="DO_S_Valve_Heater_On"           diDeviation="DI_Valve_TC_Deviation_out_of_range"           diPowerOnFeedback="DI_P_Valve_Heater_On_FB"           diControlTcBroken="DI_S_Valve_Control_TC_Broken_Alarm"           diMonitorTcBroken="DI_S_Valve_Monitor_TC_Broken_Alarm"           aoSetPoint="AO_Valve_Temperature_Setpoint"           aoSetPointLimit="AO_Valve_Temp_Limit_Setpoint"           aiFeedback="AI_S_Valve_Control_TC_Temp"           aiMonitor=""           scSetPointLimit="ValveHeaterSetPointLimit" />    <IoHeater id="ForelineHeater" display="Foreline Heater" schematicId="" unit="℃"         doPowerOn="DO_Foreline_Heater_On"         diDeviation="DI_Foreline_TC_Deviation_out_of_range"         diPowerOnFeedback="DI_Foreline_Heater_On_FB"         diControlTcBroken="DI_Foreline_Control_TC_Broken_Alarm"         diMonitorTcBroken="DI_Foreline_Monitor_TC_Broken_Alarm"         aoSetPoint="AO_Foreline_Temperature_Setpoint"         aoSetPointLimit="AO_Foreline_Temp_Limit_Setpoint"         aiFeedback="AI_Foreline_Control_TC_Temp"         aiMonitor=""         scSetPointLimit="ForeLineHeaterSetPointLimit" />    <IoHeater id="WallHeater" display="Wall Heater" schematicId="" unit="℃"              doPowerOn="DO_CHB_Wall_Heater_On"              diDeviation="DI_CHB_Wall_TC_Deviation_out_of_range"              diPowerOnFeedback="DI_CHB_Wall_Heater_On_FB"              diControlTcBroken="DI_CHB_Wall_Control_TC_Broken_Alarm"              diMonitorTcBroken="DI_CHB_Wall_Monitor_TC_Broken_Alarm"              aoSetPoint="AO_CHB_Wall_Temperature_Setpoint"              aoSetPointLimit="AO_CHB_Wall_Temp_Limit_Setpoint"              aiFeedback="AI_CHB_Wall_Control_TC_Temp"              aiMonitor=""              scSetPointLimit="WallHeaterSetPointLimit" />	  <IoHeater id="PendulumHeater" display="Pendulum Heater" schematicId="" unit="℃"              doPowerOn="DO_P_Valve_Heater_On"              diDeviation="DI_P_Valve_TC_Deviation_out_of_range"              diPowerOnFeedback="DI_P_Wall_Heater_On_FB"              diControlTcBroken="DI_P_Valve_Control_TC_Broken_Alarm"              diMonitorTcBroken="DI_P_Valve_Monitor_TC_Broken_Alarm"              aoSetPoint="AO_P_Valve_Temperature_Setpoint"              aoSetPointLimit="AO_P_Valve_Temp_Limit_Setpoint"              aiFeedback="AI_P_Valve_Control_TC_Temp"              aiMonitor=""              scSetPointLimit="PendulumHeaterSetPointLimit"               />  </IoHeaters>	  <IoHeartbeats assembly="Venus_RT" classType=" Venus_RT.Devices.IODevices.IoHeartbeat">    <IoHeartbeat  id="Heartbeat" display="" schematicId="" unit="" ao="AO_Heartbeat" ai="AI_Heartbeat_FB" />  </IoHeartbeats>  <IoResets>    <IoReset id="ResetPlcSignal" display="" schematicId="" unit="" doReset="DO_Reset_Signal" />  </IoResets>  <IoSetConfigs>    <IoSetConfig id="SetProcessPressureOffset" display="" schematicId="" unit="" aoPressureOffset="AO_Process_Pressure_Offset_Value" />  </IoSetConfigs>  <IoStatisticss>    <IoStatistics id="StatisticsRfOnTime" display="RF On Statistics" schematicId="" unit=""                  diMonitorSignal="DI_Generator_Power_Status"                  scLastPMTime="RfOnTimeLastPMTime"                  scTimeFromLastPM="RfOnTimeFromLastPM"                  scTimeTotal="RfOnTimeTotal"                  scEnableAlarm="RfOnTimeEnableAlarm"                  scPMInterval="RfOnTimePMInterval" />    <IoStatistics id="StatisticsPumpOnTime" display="Pump On Statistics" schematicId="" unit=""                  diMonitorSignal="DI_Pump_Running"                  scLastPMTime="PumpOnTimeLastPMTime"                  scTimeFromLastPM="PumpOnTimeFromLastPM"                  scTimeTotal="PumpOnTimeTotal"                  scEnableAlarm="PumpOnTimeEnableAlarm"                  scPMInterval="PumpOnTimePMInterval" />  </IoStatisticss>  <IoPlcDateTimes>    <IoPlcDateTime id="PlcDateTime" display="PlcDateTime" schematicId="" unit=""                  aiYear="AI_Year" aiMonth="AI_Month" aiDay="AI_Day" aiHour="AI_Time" aiMinute="AI_Minute" aiSecond="AI_Second" />  </IoPlcDateTimes>  <IoCylinders assembly="Venus_RT" classType="Venus_RT.Devices.IoCylinder">    <IoCylinder id="LiftPin" display="lifter Pin" schematicId="" unit="" doMotorRelay=""                doON="DO_Lift_Pin_Up" doOFF="DO_Lift_Pin_Down" diON="DI_Lift_Pin_Up_POS" diOFF="DI_Lift_Pin_Down_POS" />    <IoCylinder id="SlitDoor" display="Slit door" schematicId="" unit="" doMotorRelay=""                doON="DO_Slit_Door_Open" doOFF="DO_Slit_Door_Close" diON="DI_Slit_Door_Open_POS" diOFF="DI_Slit_Door_Close_POS" />	  </IoCylinders>  <IoLids assembly="Venus_RT" classType=" Venus_RT.Devices.IODevices.IoLid">    <IoLid id="Lid" display="Lid" schematicId="" unit="" doMotorRelay="" doON="DO_Lid_Up" doOFF="DO_Lid_Down" diON="" diOFF="DI_Lid_Closed" />  </IoLids>    <IoMessages assembly="Venus_RT" classType=" Venus_RT.Devices.IODevices.IoMessage">    <IoMessage id="Messager" display="Messager" schematicId="" unit="" doMotorRelay="" ai="" ao="AO_BaisRF_Enable" />  </IoMessages>  <IoPumpCtrls assembly="Venus_RT" classType="Venus_RT.Devices.IODevices.IoPumpCtrl">		<IoPumpCtrl id="PumpCtrl" display="Lid" schematicId="" unit="" aoPumpIOCTRLEnable="AO_Pump_IO_CTRL_Enable" doPumpRun="DO_Pump_Run" doPumpStop="DO_Pump_Stop" diDryPumpRunning="DI_Dry_Pump_Running" diBoosterPumpRunning="" diPumpRemoteStatus="DI_Pump_Remote_Status" diPumpAlarm="DI_Pump_Alarm"/>  </IoPumpCtrls>  </DeviceModelDefine>
 |