MFVentRoutine.cs 3.4 KB

123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125
  1. using Aitex.Core.RT.Routine;
  2. using Aitex.Core.RT.SCCore;
  3. using Venus_RT.Devices;
  4. using MECF.Framework.Common.Equipment;
  5. using Venus_Core;
  6. namespace Venus_RT.Modules.TM
  7. {
  8. class MFVentRoutine : ModuleRoutineBase, IRoutine
  9. {
  10. private enum VentStep
  11. {
  12. kVenting,
  13. kOpenSoftVent,
  14. KSwitchFastVent,
  15. kCloseVentValves,
  16. kOpenExhaustValve,
  17. KDelay,
  18. kCloseExhaustValve,
  19. }
  20. private int _ventingTimeout;
  21. private int _SoftVentEndPressure;
  22. private readonly JetTM _JetTM;
  23. private int _ventTimeDelay = 1;
  24. public MFVentRoutine(JetTM jetTM, ModuleName mod) : base(mod)
  25. {
  26. _JetTM = jetTM;
  27. Name = "Vent ";
  28. }
  29. public RState Start(params object[] objs)
  30. {
  31. _JetTM.TurnSoftPumpValve(Module, false);
  32. _JetTM.TurnPurgeValve(Module, false);
  33. if (_JetTM.CheckLidClosed(Module) &&
  34. _JetTM.CheckPumpValveClosed(Module) &&
  35. _JetTM.CheckPurgeValveClosed(Module))
  36. {
  37. Reset();
  38. _ventingTimeout = SC.GetValue<int>($"{Module}.VentingTimeout") * 1000;
  39. _SoftVentEndPressure= SC.GetValue<int>($"{Module}.SoftVentEndPressure");
  40. _ventTimeDelay = SC.GetValue<int>($"{Module}.OverVentTime");
  41. return Runner.Start(Module, Name);
  42. }
  43. return RState.Failed;
  44. }
  45. public RState Monitor()
  46. {
  47. Runner.Run(VentStep.kOpenSoftVent, OpenSoftVentValve, IsSoftVentEnd)
  48. .Run(VentStep.KSwitchFastVent, SwitchFastVentValve, IsPressureReady, _ventingTimeout)
  49. .Run(VentStep.kCloseVentValves, CloseVentValve, _delay_50ms)
  50. .Run(VentStep.kOpenExhaustValve, OpenExhaustValve)
  51. .Delay(VentStep.KDelay, _ventTimeDelay)
  52. .End(VentStep.kCloseExhaustValve,CloseExhaustValve);
  53. return Runner.Status;
  54. }
  55. private bool OpenSoftVentValve()
  56. {
  57. _JetTM.TurnN2Valve(true);
  58. _JetTM.TurnPurgeValve(Module, true);
  59. return true;
  60. }
  61. private bool OpenExhaustValve()
  62. {
  63. _JetTM.TurnExhaustValve(Module, true);
  64. return true;
  65. }
  66. private bool CloseExhaustValve()
  67. {
  68. _JetTM.TurnExhaustValve(Module, false);
  69. return true;
  70. }
  71. private bool IsSoftVentEnd()
  72. {
  73. return _JetTM.GetModulePressure(Module) > _SoftVentEndPressure;
  74. }
  75. private bool SwitchFastVentValve()
  76. {
  77. if (Module == ModuleName.TM)
  78. {
  79. _JetTM.TurnPurgeValve(Module, false);
  80. _JetTM.SetTMFlow(100);
  81. }
  82. _JetTM.TurnVentValve(Module, true);
  83. return true;
  84. }
  85. private bool CloseVentValve()
  86. {
  87. //_JetTM.TurnN2Valve(false);
  88. _JetTM.TurnPurgeValve(Module, false);
  89. _JetTM.TurnVentValve(Module, false);
  90. if (Module == ModuleName.TM)
  91. {
  92. _JetTM.SetTMFlow(0);
  93. }
  94. return true;
  95. }
  96. private bool IsPressureReady()
  97. {
  98. return _JetTM.IsModuleATM(Module);
  99. }
  100. public void Abort()
  101. {
  102. CloseVentValve();
  103. }
  104. }
  105. }