PendulumValve.cs 14 KB

123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182183184185186187188189190191192193194195196197198199200201202203204205206207208209210211212213214215216217218219220221222223224225226227228229230231232233234235236237238239240241242243244245246247248249250251252253254255256257258259260261262263264265266267268269270271272273274275276277278279280281282283284285286287288289290291292293294295296297298299300301302303304305306307308309310311312313314315316317318319320321322323324325326327328329330331332333334335336337338339340341342343344345346347348349350351352353354355356357358359360361362363364365366367368369370371372373374375376377378379380381382383384385386387388389390391392393394395396397398399400401402403404405406407408409410411412413414415416417418419420421422423424425426427
  1. using System;
  2. using System.Collections.Generic;
  3. using System.Diagnostics;
  4. using Venus_RT.Modules;
  5. using MECF.Framework.Common.Communications;
  6. using MECF.Framework.Common.Equipment;
  7. using Venus_Core;
  8. using Aitex.Core.RT.SCCore;
  9. using Aitex.Core.RT.Event;
  10. using Aitex.Core.RT.Device;
  11. using Aitex.Core.RT.Log;
  12. namespace Venus_RT.Devices
  13. {
  14. class PendulumValve : IDevice
  15. {
  16. public enum Operation
  17. {
  18. SetPosition,
  19. GetPositionSP,
  20. Hold,
  21. OpenValve,
  22. CloseValve,
  23. SetPressure,
  24. GetPressureSP,
  25. GetAssembly,
  26. GetPosition,
  27. GetPressure,
  28. GetSensor1Data,
  29. GetSensor2Data,
  30. GetPressureCtrlStatus,
  31. GetDeviceStatus,
  32. GetWarnings,
  33. GetSensorOffset,
  34. GetSensor1Offset,
  35. GetSensor2Offset,
  36. GetLearnStatus,
  37. GetLearnPressureLimit,
  38. GetErrorStatus,
  39. GetFatalErrorStatus,
  40. GetThrottleCycleCounter,
  41. GetIsolationCycleCounter,
  42. GetPowerUpCounter,
  43. GetHardwareConfiguration,
  44. GetFirmwareConfiguration,
  45. GetIdentification,
  46. SetAccessMode,
  47. SetInterfaceConfiguration,
  48. SetValveConfiguration,
  49. SetSensorConfiguration,
  50. SetRangeConfiguration,
  51. SetZero,
  52. SetPressureAlignment,
  53. SetLearn,
  54. DownloadLearnData,
  55. UploadLearnData,
  56. SetPIDConfiguration,
  57. GetPIDConfiguration,
  58. SetValveSpeed,
  59. GetValveSpeed,
  60. Reset,
  61. Invalid,
  62. }
  63. private readonly Dictionary<Operation, string> _noneParaCommandOp = new Dictionary<Operation, string>
  64. {
  65. {Operation.GetPositionSP, "i:38" },
  66. {Operation.Hold, "H:" },
  67. {Operation.CloseValve, "C:" },
  68. {Operation.OpenValve, "O:" },
  69. {Operation.GetPressureSP, "i:38" },
  70. {Operation.GetAssembly, "i:76" },
  71. {Operation.GetPosition, "A:" },
  72. {Operation.GetPressure, "P:" },
  73. {Operation.GetSensor1Data, "i:64" },
  74. {Operation.GetSensor2Data, "i:65" },
  75. {Operation.GetPressureCtrlStatus, "i:36" },
  76. {Operation.GetDeviceStatus, "i:30" },
  77. {Operation.GetWarnings, "i:35" },
  78. {Operation.GetSensorOffset, "i:62" },
  79. {Operation.GetSensor1Offset, "i:60" },
  80. {Operation.GetSensor2Offset, "i:61" },
  81. {Operation.GetLearnStatus, "i:32" },
  82. {Operation.GetLearnPressureLimit, "i:34" },
  83. {Operation.GetErrorStatus, "i:52" },
  84. {Operation.GetFatalErrorStatus, "i:50" },
  85. {Operation.GetThrottleCycleCounter, "i:70" },
  86. {Operation.GetIsolationCycleCounter, "i:71" },
  87. {Operation.GetPowerUpCounter, "i:72" },
  88. {Operation.GetHardwareConfiguration, "i:80" },
  89. {Operation.GetFirmwareConfiguration, "i:82" },
  90. {Operation.GetIdentification, "i:83" },
  91. };
  92. private readonly Dictionary<Operation, string> _singleParaCommandOp = new Dictionary<Operation, string>
  93. {
  94. {Operation.SetPosition, "R:{0:D6}" },
  95. {Operation.SetPressure, "S:{0:D8}" },
  96. {Operation.SetAccessMode, "c:01{0:D2}" },
  97. {Operation.SetInterfaceConfiguration, "s:20{0:D8}" },
  98. {Operation.SetValveConfiguration, "s:04{0:D2}000000" },
  99. {Operation.SetSensorConfiguration, "s:01{0:D8}" },
  100. {Operation.SetRangeConfiguration, "s:21{0:D8}" },
  101. {Operation.SetPressureAlignment, "c:6002{0:D8}" },
  102. {Operation.SetLearn, "L:{0:D8}" },
  103. {Operation.UploadLearnData, "u:{0:D3}" },
  104. {Operation.SetPIDConfiguration, "s:02{0:D8}" },
  105. {Operation.SetValveSpeed, "V:00{0:D4}" }
  106. };
  107. private readonly Dictionary<Operation, string> _twoParaCommandOp = new Dictionary<Operation, string>
  108. {
  109. {Operation.DownloadLearnData, "d:{0:D3}{1:D8}" }
  110. };
  111. private readonly Dictionary<string, string> _deviceError = new Dictionary<string, string>
  112. {
  113. {"000001", "Parity error" },
  114. {"000002", "Input buffer overflow (to many characters) " },
  115. {"000003", "Framing error (data length, number of stop bits)" },
  116. {"000010", "<CR> or <LF> missing" },
  117. {"000011", ": missing" },
  118. {"000012", "Invalid number of characters (between : and [CR][LF])" },
  119. {"000020", "Unknown command" },
  120. {"000021", "Unknown command" },
  121. {"000022", "Invalid value" },
  122. {"000023", "Invalid value" },
  123. {"000030", "Value out of range" },
  124. {"000041", "Command not applicable for hardware configuration" },
  125. {"000060", "ZERO disabled" },
  126. {"000080", "Command not accepted due to local operation" },
  127. {"000082", "Command not accepted due to synchronization, CLOSED or OPEN by digital input, safety mode or fatal error" },
  128. };
  129. public string Module { get; set; }
  130. public string Name { get; set; }
  131. public int Pressure { get; private set; }
  132. public int Position { get; private set; }
  133. public string Status { get; private set; }
  134. public bool IsOpen { get; private set; }
  135. private readonly string EOF = "\r\n";
  136. private readonly int _readInterval = 1000;
  137. private readonly int _position_unit = 100;
  138. private int _queryFlag = 0;
  139. private readonly AsyncSerialPort _serial;
  140. private Stopwatch _queryWatch = new Stopwatch();
  141. private string _lastAlarmString = string.Empty;
  142. private Operation[] _querys = new Operation[] { Operation.GetPressure, Operation.GetPosition, Operation.GetDeviceStatus, Operation.GetPressureSP };
  143. public PendulumValve(ModuleName mod)
  144. {
  145. Name = VenusDevice.PendulumValve.ToString();
  146. Module = mod.ToString();
  147. var _PortNum = SC.GetStringValue($"{mod}.PendulumValve.Port");
  148. _serial = new AsyncSerialPort(_PortNum, 9600, 8, System.IO.Ports.Parity.None, System.IO.Ports.StopBits.One, EOF);
  149. IsOpen = false;
  150. }
  151. public bool Initialize()
  152. {
  153. if (!_serial.Open())
  154. {
  155. _noRepeatAlarm("Pendulum Valve 串口无法打开");
  156. return false;
  157. }
  158. _serial.OnDataChanged += OnPortDataChanged;
  159. _serial.OnErrorHappened += OnErrorOccurred;
  160. _queryWatch.Restart();
  161. return true;
  162. }
  163. public void Monitor()
  164. {
  165. if(_queryWatch.ElapsedMilliseconds > _readInterval)
  166. {
  167. SendCommand(_querys[_queryFlag++ % 4]);
  168. _queryWatch.Restart();
  169. }
  170. }
  171. public void Reset()
  172. {
  173. }
  174. public void Terminate()
  175. {
  176. _serial?.Close();
  177. }
  178. private void OnErrorOccurred(string obj)
  179. {
  180. _noRepeatAlarm($"[{Module}] VAT Pendulum Valve error: [{obj}]");
  181. }
  182. private void OnPortDataChanged(string obj)
  183. {
  184. if (string.IsNullOrEmpty(obj))
  185. {
  186. _noRepeatAlarm("VAT Pendulum Valve receive empty message");
  187. return;
  188. }
  189. try
  190. {
  191. var data = obj.TrimEnd().Split(':');
  192. switch(data[0])
  193. {
  194. case "P":
  195. {
  196. int pressure;
  197. if (int.TryParse(data[1], out pressure))
  198. Pressure = pressure;
  199. }
  200. break;
  201. case "A":
  202. {
  203. int position;
  204. if (int.TryParse(data[1], out position))
  205. Position = position / _position_unit;
  206. }
  207. break;
  208. case "i":
  209. {
  210. _tryParseInqueryData(obj);
  211. }
  212. break;
  213. case "C":
  214. case "O":
  215. case "H":
  216. case "R":
  217. case "S":
  218. break;
  219. case "E":
  220. {
  221. _noRepeatAlarm($"[{Module}] VAT Pendulum Valve device error: {_deviceError[data[1]]}");
  222. }
  223. break;
  224. default:
  225. {
  226. _noRepeatAlarm($"VAT Pendulum Valve: unrecognized received data: {obj}");
  227. break;
  228. }
  229. }
  230. }
  231. catch (Exception ex)
  232. {
  233. _noRepeatAlarm($"[{Module}] VAT Pendulum Valve error: [{ex.Message}], Data: {obj}");
  234. }
  235. }
  236. private bool SendCommand(Operation op)
  237. {
  238. if(_noneParaCommandOp.ContainsKey(op))
  239. {
  240. return _serial.Write(_noneParaCommandOp[op] + EOF);
  241. }
  242. else
  243. {
  244. return false;
  245. }
  246. }
  247. private bool SendCommand(Operation op, int data)
  248. {
  249. if(_singleParaCommandOp.ContainsKey(op))
  250. {
  251. var cmd = string.Format(_singleParaCommandOp[op], data) + EOF;
  252. return _sendCmd(cmd);
  253. }
  254. else
  255. {
  256. _noRepeatAlarm("This VAT Pendulum Valve command need 1 data");
  257. return false;
  258. }
  259. }
  260. private bool _sendCmd(string cmd)
  261. {
  262. return _serial.Write(cmd);
  263. }
  264. private void _noRepeatAlarm(string alarm)
  265. {
  266. if (_lastAlarmString != alarm)
  267. {
  268. _lastAlarmString = alarm;
  269. LOG.Write(eEvent.ERR_PENDULUM_VALVE, ModuleHelper.Converter(Module), alarm);
  270. EV.PostAlarmLog(Module, alarm);
  271. }
  272. }
  273. private bool _tryParseInqueryData(string data)
  274. {
  275. var cmdPrix = data.Substring(0, 4);
  276. Operation oper = Operation.Invalid;
  277. foreach( var item in _noneParaCommandOp)
  278. {
  279. if(item.Value == cmdPrix)
  280. {
  281. oper = item.Key;
  282. break;
  283. }
  284. }
  285. if( oper == Operation.Invalid)
  286. {
  287. return false;
  288. }
  289. switch(oper)
  290. {
  291. case Operation.GetDeviceStatus:
  292. {
  293. Status = data.Substring(4, 8);
  294. if(Status[1] == 'E')
  295. {
  296. // Fatal Error
  297. _noRepeatAlarm($"Device Status error:{Status}");
  298. }
  299. else if(Status[3] == '1')
  300. {
  301. // Warning Present
  302. _noRepeatAlarm($"Device Warning Present:{Status}");
  303. }
  304. }
  305. break;
  306. case Operation.GetPressureSP:
  307. case Operation.GetPositionSP:
  308. {
  309. string Pressure = data.Substring(4, 8);
  310. //LOG.Write(eEvent.EV_DEVICE_INFO, Module, $" PV Pressure SetPoint: {Pressure}");
  311. }
  312. break;
  313. default:
  314. break;
  315. }
  316. return true;
  317. }
  318. public bool SetPosition(int postion)
  319. {
  320. if(_CheckStatus())
  321. {
  322. IsOpen = postion > 0;
  323. return SendCommand(Operation.SetPosition, postion * _position_unit);
  324. }
  325. return false;
  326. }
  327. public bool SetPressure(int pressure)
  328. {
  329. if(_CheckStatus())
  330. {
  331. IsOpen = true;
  332. return SendCommand(Operation.SetPressure, pressure);
  333. }
  334. return false;
  335. }
  336. public bool Hold()
  337. {
  338. return SendCommand(Operation.Hold);
  339. }
  340. public bool TurnValve(bool on)
  341. {
  342. if(_CheckStatus(on))
  343. {
  344. IsOpen = on;
  345. return SendCommand(on ? Operation.OpenValve : Operation.CloseValve);
  346. }
  347. return false;
  348. }
  349. bool _CheckStatus(bool bTurnOn = false)
  350. {
  351. if (Status != null && Status[1] == 'E')
  352. {
  353. _noRepeatAlarm($"PendulumValve is error status, can do turn on/off operation.");
  354. return false;
  355. }
  356. var _chamber = DEVICE.GetDevice<JetPM>(Module);
  357. if (bTurnOn && !_chamber.IsTurboPumpAtSpeed)
  358. {
  359. _noRepeatAlarm($"Turbo Pump not at speed, can not turn on pendulum valve.");
  360. return false;
  361. }
  362. if (_chamber.ForelinePressure > 500)
  363. {
  364. LOG.Write(eEvent.WARN_DEVICE_INFO, Module, $"Foreline Pressure:{_chamber.ForelinePressure} is too high, can not turn on pendulum valve.");
  365. //_noRepeatAlarm($"Foreline Pressure:{_chamber.ForelinePressure} is too high, can not turn on pendulum valve.");
  366. return false;
  367. }
  368. return true;
  369. }
  370. }
  371. }