VATPerformanceViewModel.cs 6.8 KB

123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182183184185186187188189190191192193194
  1. using LiveCharts;
  2. using MECF.Framework.Common.DataCenter;
  3. using MECF.Framework.Common.OperationCenter;
  4. using Microsoft.Win32;
  5. using Prism.Commands;
  6. using Prism.Mvvm;
  7. using System;
  8. using System.IO;
  9. using System.Linq;
  10. using System.Windows.Threading;
  11. using Venus_MainPages.Unity;
  12. using Venus_Unity;
  13. namespace Venus_MainPages.ViewModels
  14. {
  15. internal class VATPerformanceViewModel : BindableBase
  16. {
  17. #region 私有字段
  18. private int m_GasFlow;
  19. private int m_GasTime;
  20. private int m_GasSelectedIndex;
  21. public string ModuleName;
  22. ChartValues<double> m_CurrentLineSeries = new ChartValues<double>();
  23. ChartValues<double> m_ReferenceLineSeries = new ChartValues<double>();
  24. DispatcherTimer timer = new DispatcherTimer();
  25. VATPerformanceResult m_VATPerformanceResult;
  26. private bool m_MFC7IsEnable;
  27. private bool m_MFC8IsEnable;
  28. #endregion
  29. #region 属性
  30. public int GasFlow
  31. {
  32. get { return m_GasFlow; }
  33. set { SetProperty(ref m_GasFlow, value); }
  34. }
  35. public int GasTime
  36. {
  37. get { return m_GasTime; }
  38. set { SetProperty(ref m_GasTime, value); }
  39. }
  40. public int GasSelectedIndex
  41. {
  42. get { return m_GasSelectedIndex; }
  43. set { SetProperty(ref m_GasSelectedIndex, value); }
  44. }
  45. public ChartValues<double> CurrentLineSeries
  46. {
  47. get { return m_CurrentLineSeries; }
  48. set { SetProperty(ref m_CurrentLineSeries, value); }
  49. }
  50. public ChartValues<double> ReferenceLineSeries
  51. {
  52. get { return m_ReferenceLineSeries; }
  53. set { SetProperty(ref m_ReferenceLineSeries, value); }
  54. }
  55. public bool MFC7IsEnable
  56. {
  57. get { return m_MFC7IsEnable; }
  58. set { SetProperty(ref m_MFC7IsEnable, value); }
  59. }
  60. public bool MFC8IsEnable
  61. {
  62. get { return m_MFC8IsEnable; }
  63. set { SetProperty(ref m_MFC8IsEnable, value); }
  64. }
  65. #endregion
  66. #region 命令
  67. private DelegateCommand _SelectGasCommand;
  68. public DelegateCommand SelectGasCommand =>
  69. _SelectGasCommand ?? (_SelectGasCommand = new DelegateCommand(OnSelectGas));
  70. private DelegateCommand _StartCommand;
  71. public DelegateCommand StartCommand =>
  72. _StartCommand ?? (_StartCommand = new DelegateCommand(OnStart));
  73. private DelegateCommand _LoadReferenceCommand;
  74. public DelegateCommand LoadReferenceCommand =>
  75. _LoadReferenceCommand ?? (_LoadReferenceCommand = new DelegateCommand(OnLoadReference));
  76. private DelegateCommand _AbortCommand;
  77. public DelegateCommand AbortCommand =>
  78. _AbortCommand ?? (_AbortCommand = new DelegateCommand(OnAbort));
  79. private DelegateCommand _SaveCommand;
  80. public DelegateCommand SaveCommand =>
  81. _SaveCommand ?? (_SaveCommand = new DelegateCommand(OnSave));
  82. #endregion
  83. #region 构造函数
  84. public VATPerformanceViewModel()
  85. {
  86. OnSelectGas();
  87. GasTime = 60;
  88. timer.Interval = TimeSpan.FromSeconds(2);
  89. timer.Tick += Timer_Tick;
  90. }
  91. #endregion
  92. #region 命令方法
  93. private void OnSelectGas()
  94. {
  95. var value=Convert.ToInt32( QueryDataClient.Instance.Service.GetConfig($"{ModuleName}.MfcGas{(GasSelectedIndex+1).ToString()}.MfcN2Scale"));
  96. var xishu= Convert.ToDouble(QueryDataClient.Instance.Service.GetConfig($"{ModuleName}.MfcGas{(GasSelectedIndex + 1).ToString()}.MfcScaleFactor"));
  97. GasFlow = (int)(value * xishu) / 2;
  98. }
  99. //public enum CMPressure
  100. //{
  101. // CM1,
  102. // CM2,
  103. //}
  104. //private CMPressure currentCMPressure = CMPressure.CM1;
  105. private void OnStart()
  106. {
  107. //currentCMPressure = CMPressure.CM1;
  108. m_VATPerformanceResult = new VATPerformanceResult();
  109. m_VATPerformanceResult.StartTime = DateTime.Now.ToString();
  110. m_VATPerformanceResult.FlowTime = GasTime;
  111. m_VATPerformanceResult.GasName = $"Gas{GasSelectedIndex+1}";
  112. CurrentLineSeries = new ChartValues<double>();
  113. timer.Start();
  114. InvokeClient.Instance.Service.DoOperation($"{ModuleName}.VATPerformanceTest", GasSelectedIndex+1, 1000 * GasTime, GasFlow);
  115. }
  116. private void OnLoadReference()
  117. {
  118. //ReferenceLineSeries.Clear();
  119. //for (int i = 0; i < 21; i++)
  120. //{
  121. // double value = Math.Round((double)GasFlow / (double)((i + 2) * 50),3);
  122. // ReferenceLineSeries.Add(value);
  123. //}
  124. OpenFileDialog dialog = new OpenFileDialog();
  125. dialog.Filter = ".json|*.json";
  126. dialog.InitialDirectory = Path.Combine(QueryDataClient.Instance.Service.GetData("GetRTPath").ToString(), "VATPerformanceResult");
  127. if (dialog.ShowDialog() == true)
  128. {
  129. string SelectedPath = dialog.FileName;
  130. var value = SerializeHelper.Instance.ReadFromJsonFile<VATPerformanceResult>(SelectedPath);
  131. ReferenceLineSeries.Clear();
  132. value.ValuePairs.ForEach(x =>
  133. {
  134. ReferenceLineSeries.Add(x);
  135. });
  136. }
  137. else
  138. {
  139. ReferenceLineSeries.Clear();
  140. ReferenceLineSeries.Add(0);
  141. }
  142. }
  143. private void OnAbort()
  144. {
  145. timer.Stop();
  146. InvokeClient.Instance.Service.DoOperation($"{ModuleName}.Abort");
  147. CurrentLineSeries = new ChartValues<double>();
  148. }
  149. private void OnSave()
  150. {
  151. SerializeHelper.Instance.WriteToJsonFile<VATPerformanceResult>(m_VATPerformanceResult, $"VATPerformanceResult/{m_VATPerformanceResult.GasName}/{DateTime.Now.ToString("yyyyMMddHHmm")}.json");
  152. }
  153. #endregion
  154. #region 私有方法
  155. private void Timer_Tick(object sender, EventArgs e)
  156. {
  157. CurrentLineSeries.Clear();
  158. var values = QueryDataClient.Instance.Service.GetData($"{ModuleName}.VATPerformanceResult").ToString();
  159. values.Split(',').ToList().ForEach(x =>
  160. {
  161. if (x != "")
  162. {
  163. CurrentLineSeries.Add(Math.Round( Convert.ToDouble(x),3));
  164. }
  165. });
  166. if (CurrentLineSeries.Count == 20)
  167. {
  168. timer.Stop();
  169. }
  170. MFC7IsEnable = (bool)QueryDataClient.Instance.Service.GetConfig($"{ModuleName}.MfcGas7.Enable");
  171. MFC8IsEnable = (bool)QueryDataClient.Instance.Service.GetConfig($"{ModuleName}.MfcGas8.Enable");
  172. }
  173. #endregion
  174. }
  175. }