| 123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182183184185186187188189190191192193194195196197198199200201202203204205206207208209210211212213214215216217218219220221222223224225226227228229230231232233234235236237238239240241242243244245246247248249250251252253254255256257258259260261262263264265266267268269270271272273274275276277278279280281282283284285286287288289290291292293294295296297298299300301302303304305306307308309310311312313314315316317318319320321322323324325326327328329330331332333334335336337338339340341342343344345346347348349350351352353354355356357358359360361362363364365366367368369370371372373374375376377378379380381382383384385386387388389390391392393394395396397398399400401402403404405406407408409410411412413414415416417418419420421422423424425426427428429430431432433434435436437438439440441442443444445446447448449450451452453454455456457458459460461462463464465466467468469470471472473474475476477478479480481482483484485486487488489490491492493494495496497498499500501502503504505506507508509510511512513514515516517518519520521522523524525526527528529530531532533534535536537538539540541542543544545546547548549550551552553554555556557558559560561562563564565566567568569570571572573574575576577578579580581582583584585586587588589590591592593594595596597598599600601602603604605606607608609610611612613614615616617618619620621622623624625626627628629630631632633634635636637638639640641642643644645646647648649650651652653654655656657658659660661662663664665666667668669670671672673674675676677678679680681682683684685686687688689690691692693694695696697698699700701702703704705706707708709710711712713714715716717718719720721722723724725726727728729730731732733734735736737738739740741742743744745746747748749750751752753754755756757758759760761762763764765766767768769770771772773774775776777778779780781782783784785786787788789790791792793794795796797798799800801802803804805806807808809810811812813814815816817818819820821822823824825826827828829830831832833834835836837838839840841842843844845846847848849850851852853854855856857858859860861862863864865866867868869870871872873874875876877878879880881882883884885886887888889890891892893894895896897898899900901902903904905906907908909910911912913914915916917918919920921922923924925926927928929930931932933934935936937938939940941942943944945946947948949950951952953954955956957958959960961962963964965966967968969970971972973974975976977978979980981982983984985986987988989990991992993994995996997998999100010011002100310041005100610071008100910101011101210131014101510161017101810191020102110221023102410251026102710281029103010311032103310341035103610371038103910401041104210431044104510461047104810491050105110521053105410551056105710581059106010611062106310641065106610671068106910701071107210731074107510761077107810791080108110821083108410851086108710881089109010911092109310941095109610971098109911001101110211031104110511061107110811091110111111121113111411151116111711181119112011211122112311241125112611271128112911301131113211331134113511361137113811391140114111421143114411451146114711481149115011511152115311541155115611571158 | using Aitex.Core.Common.DeviceData;using Aitex.Core.RT.Device;using Aitex.Core.RT.Device.Unit;using Aitex.Core.RT.SCCore;using Aitex.Core.RT.Log;using MECF.Framework.Common.Device.Bases;using MECF.Framework.Common.Equipment;using System;using Venus_Core;using Venus_RT.Devices.IODevices;using IoMfc = Venus_RT.Devices.IODevices.IoMfc;using IoHeartbeat = Venus_RT.Devices.IODevices.IoHeartbeat;using System.Threading.Tasks;using System.Diagnostics;using Aitex.Core.RT.DataCenter;using Aitex.Core.Util;namespace Venus_RT.Devices{    class JetKepler2200APM : JetPMBase    {        private readonly IoLid _Lid;        //private readonly IoLid _LidLoadlock;        private readonly IoCylinder _slitDoor;        //private readonly IoCylinder _LiftPin;        //private readonly IoCylinder _LoadLockArm;        private readonly IoValve _PVN21Valve;        private readonly IoValve _PVN22Valve;        private readonly IoValve _PV11Valve;        private readonly IoValve _PV12Valve;        private readonly IoValve _PV21Valve;        private readonly IoValve _PV22Valve;        private readonly IoValve _PV31Valve;        private readonly IoValve _PV32Valve;        private readonly IoValve _PV41Valve;        private readonly IoValve _PV42Valve;        private readonly IoValve _N2Valve;        private readonly IoValve _O2Valve;        private readonly IoValve _PurgeValve;        private readonly IoValve _Mfc1Valve;        private readonly IoValve _Mfc2Valve;        private readonly IoValve _Mfc3Valve;        private readonly IoValve _Mfc4Valve;        private readonly IoValve _Mfc5Valve;        private readonly IoValve _Mfc6Valve;        private readonly IoValve _Mfc7Valve;        private readonly IoValve _Mfc8Valve;        //private readonly IoValve _PVHe1Valve;        //private readonly IoValve _PVHe2Valve;        private readonly IoValve _GasFinalValve;        private readonly IoValve _SoftPumpValve;        private readonly IoValve _FastPumpValve;        private readonly IoValve _TurboPumpPumpingValve;        private readonly IoValve _TurboPumpPurgeValve;        private readonly IoValve _GuageValve;        //private readonly IoValve _LoadlockVentValve;        //private readonly IoValve _LoadlockPumpingValve;        private readonly IoValve _N2Purge1Valve;        private readonly IoValve _N2Purge2Valve;        private readonly IoValve _PenningGuageValve;        private readonly IoSensor _ATM_sw;        private readonly IoSensor _CDAPressure;        //private readonly IoSensor _ATM_Loadlock_sw;        private readonly IoSensor _N2Pressure_sw;        private readonly IoSensor _VAC_sw;        private readonly IoSensor _WLK_sw;        private readonly IoSensor _Water_Flow;        private readonly IoSensor _RFG_Interlock;        //private readonly IoSensor _PM_Lid_Closed;        private readonly IoSensor _Source_RF_Match_Interlock;        //private readonly IoSensor _PM_SlitDoor_Closed;        private readonly IoSensor _TurboPumpInterlock;        private readonly IoSensor _GasBoxDoor;        private readonly IoSensor _GasBoxPressure;        private readonly IoSensor _GasBoxN2Flow_sw;        private readonly IoSensor _N2PurgePressure_sw;        private readonly IoSensor _WaferTransferPosi_sw;        private readonly IoSensor _TopShieldCoverClosedAlarm;        private readonly IoSensor _ScrubberIsOK;        private readonly F_TRIG ScrubberTrigger=new F_TRIG();        //private readonly IoHeartbeat _Heartbeat;        private readonly IoHighTemperatureHeater _highTemperatureHeater;        //private readonly F_TRIG _GasBoxN2FlowSwitchTrigger = new F_TRIG();        private readonly Stopwatch _GasBoxN2FlowSwitchStopWatch = new Stopwatch();        private readonly PumpBase _MainPump;        private readonly AdixenTurboPump _TurboPump;        private readonly PendulumValve _pendulumValve;        private readonly RfPowerBase _Generator;//srf=>AdTecGenerator        private readonly RfMatchBase _Match;        //private readonly RfMatchBase _RFBox;        //private readonly RfPowerBase _GeneratorBias;//brf=>CometRF        //private readonly RfMatchBase _BiasMatch;        //private readonly IoSignalTower _SignalTower;        //private readonly IoHeater _ForelineTC;        private readonly IoHeater _WallTC;        private readonly IoPressureControl _pressureController;        private readonly IoGasStick[] _gasLines;        private readonly IoGasStick _gasLineN2;        //private readonly IoBacksideHe _backsideHe;        private readonly double _foreline_interlock_pressure = 750;        private Stopwatch _GasRFStopWatch = new Stopwatch();        private bool _GasFlag = false;        //private PressureType _PressureType;        private double processPressureLimit;        private ScrubberMode _scrubberMode;        // 盖子的状态        public override bool IsLidClosed => _Lid.OFFFeedback;        //public override bool IsLidLoadlockClosed => _LidLoadlock.OFFFeedback;        public override bool IsSlitDoorClosed => _slitDoor.State == CylinderState.Close;        public override bool IsPumpRunning => _MainPump.IsRunning;        public override bool IsISOOpen => _TurboPumpPumpingValve.Status;        public override bool IsTurboPumpRunning => _TurboPump.IsRunning;        public override bool IsTurboPumpAtSpeed => _TurboPump.AtSpeed;        public override float TurboPumpSpeed => _TurboPump.Speed;        public override bool HasPumpError => _MainPump.IsError || !_MainPump.IsRunning;        public override bool HasTurboPumpError => _TurboPump.IsError || !_TurboPump.IsRunning;        public override bool IsCDA_OK => _CDAPressure.Value;        public override bool IsFastPumpOpened => _FastPumpValve.Status;        public override bool IsSoftPumpOpened => _SoftPumpValve.Status;        public override bool IsMfc1ValveOpened => _Mfc1Valve.Status;        public override bool IsMfc2ValveOpened => _Mfc2Valve.Status;        public override bool IsMfc3ValveOpened => _Mfc3Valve.Status;        public override bool IsMfc4ValveOpened => _Mfc4Valve.Status;        public override bool IsMfc5ValveOpened => _Mfc5Valve.Status;        public override bool IsMfc6ValveOpened => _Mfc6Valve.Status;        public override bool IsMfc7ValveOpened => _Mfc7Valve.Status;        public override bool IsMfc8ValveOpened => _Mfc8Valve.Status;        public override bool IsGuageValveOpened => _GuageValve.Status;        // 压力信号        public override bool IsATM => _ATM_sw.Value;        public override bool PVN22ValveIsOpen => _PVN22Valve.Status;        //public override bool LiftPinIsDown => false;        //public override bool LiftPinIsUp => false;        //public override bool IsATMLoadlock => _ATM_Loadlock_sw.Value;        //public override bool IsVACLoadLock => LoadlockPressure <= 1000;        public override bool IsVAC => _VAC_sw.Value;        public override bool IsWaterFlowOk => _Water_Flow.Value;        public override bool IsWLK => _WLK_sw.Value;        public override bool IsRFGInterlockOn => _RFG_Interlock.Value;        //public override bool PMLidClosed => _PM_Lid_Closed.Value;        public override bool TurboPumpInterlock => _TurboPumpInterlock.Value;        public override bool SourceRFMatchInterlock => _Source_RF_Match_Interlock.Value;        //public override bool SlitDoorClosed => _PM_SlitDoor_Closed.Value;        public override HighTemperatureHeaterPosition HighTemperatureHeaterPosition => _highTemperatureHeater.CurrentPosition;        public override double CalculationPressure        {            get            {                if (_GuageValve.Status)                {                    return ProcessPressure;                }                else                {                    return ChamberPressure;                }            }        }        public override double ProcessPressure => _pendulumValve.Pressure;        public override double ChamberPressure => _pressureController.PressureGauge.Value;        public override double ForelinePressure => _pressureController.ForelineGauge.Value;        public override double PenningGuagePressure => _pressureController.PenningGauge.Value;        public override double TargetPressure => ChamberPressure;        public override float ReflectPower => _Generator.ReflectPower;        public override float ForwardPower => _Generator.ForwardPower;        public override float RFMatchC1 => _Match != null ? _Match.TunePosition1 : 0;        public override float RFMatchC2 => _Match != null ? _Match.TunePosition2 : 0;        //public override float RFBoxC1 => _RFBox != null ? _RFBox.TunePosition1 : 0;        public override double MFC1FeedBack => DEVICE.GetDevice<IoMfc>($"{Module}.MfcGas1").FeedBack;        public override double MFC2FeedBack => DEVICE.GetDevice<IoMfc>($"{Module}.MfcGas2").FeedBack;        public override double MFC3FeedBack => DEVICE.GetDevice<IoMfc>($"{Module}.MfcGas3").FeedBack;        public override double MFC4FeedBack => DEVICE.GetDevice<IoMfc>($"{Module}.MfcGas4").FeedBack;        public override double MFC5FeedBack => DEVICE.GetDevice<IoMfc>($"{Module}.MfcGas5").FeedBack;        public override double MFC6FeedBack => DEVICE.GetDevice<IoMfc>($"{Module}.MfcGas6").FeedBack;        public override double MFC7FeedBack => DEVICE.GetDevice<IoMfc>($"{Module}.MfcGas7").FeedBack;        public override double MFC8FeedBack => DEVICE.GetDevice<IoMfc>($"{Module}.MfcGas8").FeedBack;        public override float ChamberTemperature => _highTemperatureHeater.HighTemperatureHighHeaterTemperature;        public override float PendulumPressure => _pendulumValve.Pressure;        public override float PendulumPosition => _pendulumValve.Position;        public override bool IsAllowRobotTransfer => _WaferTransferPosi_sw.Value;        public override bool ScrubberIsOK => _ScrubberIsOK.Value;        public new ModuleName Module { get; }        //public override bool CheckAtm()        //{        //    return _ATM_sw.Value && ChamberPressure > 700000;        //}        public override bool CheckSlitDoorOpen()        {            return _slitDoor.State == CylinderState.Open;        }        public override bool CheckSlitDoorClose()        {            return _slitDoor.State == CylinderState.Close;        }        public override double TotalGasSetpoint        {            get            {                double sum = 0;                foreach (var gas in _gasLines)                {                    sum += gas.FlowSP;                }                return sum;            }        }        public override bool HasGasOutOfRange        {            get            {                foreach (var gas in _gasLines)                {                    if (!gas.IsOutOfRange)                        return false;                }                return true;            }        }        public override bool PendulumValveIsOpen()        {            return _pendulumValve.IsOpen;        }        public override bool IsBiasRFAble()        {            return false;        }        #region 构造函数        public JetKepler2200APM(ModuleName moduleName) : base(moduleName)        {            Module = moduleName;            _Lid = DEVICE.GetDevice<IoLid>($"{Module}.{VenusDevice.Lid}");            //_LidLoadlock = DEVICE.GetDevice<IoLid>($"{Module}.{VenusDevice.LidLoadlock}");            _slitDoor = DEVICE.GetDevice<IoCylinder>($"{Module}.{VenusDevice.SlitDoor}");            //_LiftPin = DEVICE.GetDevice<IoCylinder>($"{Module}.{VenusDevice.LiftPin}");            //_LoadLockArm = DEVICE.GetDevice<IoCylinder>($"{Module}.{VenusDevice.LoadLockArm}");            _PVN21Valve = DEVICE.GetDevice<IoValve>($"{Module}.{VenusDevice.ValvePVN21}");            _PVN22Valve = DEVICE.GetDevice<IoValve>($"{Module}.{VenusDevice.ValvePVN22}");            _PV11Valve = DEVICE.GetDevice<IoValve>($"{Module}.{VenusDevice.ValvePV11}");            _PV12Valve = DEVICE.GetDevice<IoValve>($"{Module}.{VenusDevice.ValvePV12}");            _PV21Valve = DEVICE.GetDevice<IoValve>($"{Module}.{VenusDevice.ValvePV21}");            _PV22Valve = DEVICE.GetDevice<IoValve>($"{Module}.{VenusDevice.ValvePV22}");            _PV31Valve = DEVICE.GetDevice<IoValve>($"{Module}.{VenusDevice.ValvePV31}");            _PV32Valve = DEVICE.GetDevice<IoValve>($"{Module}.{VenusDevice.ValvePV32}");            _PV41Valve = DEVICE.GetDevice<IoValve>($"{Module}.{VenusDevice.ValvePV41}");            _PV42Valve = DEVICE.GetDevice<IoValve>($"{Module}.{VenusDevice.ValvePV42}");            _N2Valve = DEVICE.GetDevice<IoValve>($"{Module}.{VenusDevice.ValveN2}");            _O2Valve = DEVICE.GetDevice<IoValve>($"{Module}.{VenusDevice.ValveO2}");            _PurgeValve = DEVICE.GetDevice<IoValve>($"{Module}.{VenusDevice.ValvePurge}");            _Mfc1Valve = DEVICE.GetDevice<IoValve>($"{Module}.{VenusDevice.ValveMfc1}");            _Mfc2Valve = DEVICE.GetDevice<IoValve>($"{Module}.{VenusDevice.ValveMfc2}");            _Mfc3Valve = DEVICE.GetDevice<IoValve>($"{Module}.{VenusDevice.ValveMfc3}");            _Mfc4Valve = DEVICE.GetDevice<IoValve>($"{Module}.{VenusDevice.ValveMfc4}");            _Mfc5Valve = DEVICE.GetDevice<IoValve>($"{Module}.{VenusDevice.ValveMfc5}");            _Mfc6Valve = DEVICE.GetDevice<IoValve>($"{Module}.{VenusDevice.ValveMfc6}");            _Mfc7Valve = DEVICE.GetDevice<IoValve>($"{Module}.{VenusDevice.ValveMfc7}");            _Mfc8Valve = DEVICE.GetDevice<IoValve>($"{Module}.{VenusDevice.ValveMfc8}");            //_PVHe1Valve = DEVICE.GetDevice<IoValve>($"{Module}.{VenusDevice.ValvePVHe1}");            //_PVHe2Valve = DEVICE.GetDevice<IoValve>($"{Module}.{VenusDevice.ValvePVHe2}");            _GasFinalValve = DEVICE.GetDevice<IoValve>($"{Module}.{VenusDevice.ValveGasFinal}");            _SoftPumpValve = DEVICE.GetDevice<IoValve>($"{Module}.{VenusDevice.ValveSoftPump}");            _FastPumpValve = DEVICE.GetDevice<IoValve>($"{Module}.{VenusDevice.ValveFastPump}");            _TurboPumpPumpingValve = DEVICE.GetDevice<IoValve>($"{Module}.{VenusDevice.ValveTurboPumpPumping}");            _TurboPumpPurgeValve = DEVICE.GetDevice<IoValve>($"{Module}.{VenusDevice.ValveTurboPumpPurge}");            _GuageValve = DEVICE.GetDevice<IoValve>($"{Module}.{VenusDevice.ValveGuage}");            _N2Purge1Valve = DEVICE.GetDevice<IoValve>($"{Module}.{VenusDevice.ValveN2Purge1}");            _N2Purge2Valve = DEVICE.GetDevice<IoValve>($"{Module}.{VenusDevice.ValveN2Purge2}");            _PenningGuageValve = DEVICE.GetDevice<IoValve>($"{Module}.{VenusDevice.ValvePenningGauge}");            //_LoadlockVentValve = DEVICE.GetDevice<IoValve>($"{Module}.{VenusDevice.ValveLoadlockVent}");            //_LoadlockPumpingValve = DEVICE.GetDevice<IoValve>($"{Module}.{VenusDevice.ValveLoadlockPumping}");            _ATM_sw = DEVICE.GetDevice<IoSensor>($"{Module}.SensorATMSwitch");            //_ATM_Loadlock_sw = DEVICE.GetDevice<IoSensor>($"{Module}.SensorLoadlockATMSwitch");            _N2Pressure_sw = DEVICE.GetDevice<IoSensor>($"{Module}.N2PressureOk");            _VAC_sw = DEVICE.GetDevice<IoSensor>($"{Module}.SensorVacSwitch");            _Water_Flow = DEVICE.GetDevice<IoSensor>($"{Module}.SensorWaterFlowOk");            _WLK_sw = DEVICE.GetDevice<IoSensor>($"{Module}.SensorWaterLeakOk");            _CDAPressure = DEVICE.GetDevice<IoSensor>($"{Module}.SensorCDAPressureOk");            _RFG_Interlock = DEVICE.GetDevice<IoSensor>($"{Module}.GeneratorInterlock");            //_PM_Lid_Closed = DEVICE.GetDevice<IoSensor>($"{Module}.SensorPMLidClosed");            _Source_RF_Match_Interlock = DEVICE.GetDevice<IoSensor>($"{Module}.RFMatchInterlock");            //_PM_SlitDoor_Closed = DEVICE.GetDevice<IoSensor>($"{Module}.SensorSlitDoorClosed");            _TurboPumpInterlock = DEVICE.GetDevice<IoSensor>($"{Module}.TurboPumpInterlock");            _GasBoxDoor = DEVICE.GetDevice<IoSensor>($"{Module}.GasBoxDoorSW");            _GasBoxPressure = DEVICE.GetDevice<IoSensor>($"{Module}.GasBoxPressureSW");            _GasBoxN2Flow_sw = DEVICE.GetDevice<IoSensor>($"{Module}.GasBoxN2FlowSwitch");            _N2PurgePressure_sw = DEVICE.GetDevice<IoSensor>($"{Module}.N2PurgePressureSwitch");            //_ForelineTC = DEVICE.GetDevice<IoHeater>($"{Module}.ForelineHeater");            _WallTC = DEVICE.GetDevice<IoHeater>($"{Module}.WallHeater");            _WaferTransferPosi_sw = DEVICE.GetDevice<IoSensor>($"{Module}.WaferTransferPosi");            _TopShieldCoverClosedAlarm = DEVICE.GetDevice<IoSensor>($"{Module}.TOPShieldCoverClosedAlarm");            //_SignalTower = DEVICE.GetDevice<IoSignalTower>($"{Module}.SignalTower");            _ScrubberIsOK = DEVICE.GetDevice<IoSensor>($"{Module}.SCRUBBEROK");            _CDAPressure = DEVICE.GetDevice<IoSensor>($"{Module}.SensorCDAPressureOk");            _pressureController = DEVICE.GetDevice<IoPressureControl>($"{Module}.{VenusDevice.PressureControl}");            _gasLines = new IoGasStick[8];            for (int index = 0; index < 8; index++)            {                _gasLines[index] = DEVICE.GetDevice<IoGasStick>($"{Module}.GasStick{index + 1}");            }            _gasLineN2 = DEVICE.GetDevice<IoGasStick>($"{Module}.GasStickN2");            //_backsideHe = DEVICE.GetDevice<IoBacksideHe>($"{Module}.BacksideHelium");            _highTemperatureHeater = DEVICE.GetDevice<IoHighTemperatureHeater>($"{Module}.HighTemperatureHeater");            _MainPump = DEVICE.GetDevice<PumpBase>($"{Module}.{VenusDevice.MainPump}");            // RS232 Dry pump, SKY            if (SC.GetValue<int>($"{Module}.DryPump.CommunicationType") == (int)CommunicationType.RS232)            {                if (SC.GetValue<int>($"{Module}.DryPump.MFG") == (int)DryPumpMFG.SKY)                {                    _MainPump = DEVICE.GetDevice<SkyPump>($"{Module}.{VenusDevice.MainPump}");                }                else if (SC.GetValue<int>($"{Module}.DryPump.MFG") == (int)DryPumpMFG.Edwards)                {                    _MainPump = DEVICE.GetDevice<EdwardsPump>($"{Module}.{VenusDevice.MainPump}");                }            }            //_ESCHV = DEVICE.GetDevice<ESC5HighVoltage>($"{Module}.{VenusDevice.ESCHV}");            _TurboPump = DEVICE.GetDevice<AdixenTurboPump>($"{Module}.{VenusDevice.TurboPump}");            _pendulumValve = DEVICE.GetDevice<PendulumValve>($"{Module}.{VenusDevice.PendulumValve}");            //if (SC.GetValue<bool>($"{Module}.Chiller.EnableChiller") &&            //    SC.GetValue<int>($"{Module}.Chiller.CommunicationType") == (int)CommunicationType.RS232)            //{            //    if (SC.GetValue<int>($"{Module}.Chiller.MFG") == (int)ChillerMFG.SMC)            //    {            //        _Chiller = DEVICE.GetDevice<SMCChiller>($"{Module}.{VenusDevice.Chiller}");            //    }            //    else if (SC.GetValue<int>($"{Module}.Chiller.MFG") == (int)ChillerMFG.AIRSYS)            //    {            //        _Chiller = DEVICE.GetDevice<AIRSYSChiller>($"{Module}.{VenusDevice.Chiller}");            //    }            //}            // RS223 AdTec Generator            if (SC.GetValue<int>($"{Module}.Rf.CommunicationType") == (int)CommunicationType.RS232 &&                SC.GetValue<int>($"{Module}.Rf.MFG") == (int)GeneratorMFG.AdTec)            {                _Generator = DEVICE.GetDevice<AdTecGenerator>($"{Module}.{VenusDevice.Rf}");            }            //_Heartbeat = DEVICE.GetDevice<IoHeartbeat>($"{Module}.{VenusDevice.Heartbeat}");            // Ethernet Comet Generator Bias            //if (SC.GetValue<bool>($"{Module}.BiasRf.EnableBiasRF"))            //{            //    if (SC.GetValue<int>($"{Module}.BiasRf.CommunicationType") == (int)CommunicationType.Ethernet &&            //        SC.GetValue<int>($"{Module}.BiasRf.MFG") == (int)GeneratorMFG.Comet)            //    {            //        _GeneratorBias = DEVICE.GetDevice<CometRF>($"{Module}.{VenusDevice.BiasRf}");            //    }            //    else if (SC.GetValue<int>($"{Module}.BiasRf.MFG") == (int)GeneratorMFG.AdTec)            //    {            //        _GeneratorBias = DEVICE.GetDevice<AdTecGenerator>($"{Module}.{VenusDevice.BiasRf}");            //    }            //}            if (SC.GetValue<int>($"{Module}.Match.CommunicationType") == (int)CommunicationType.RS232 &&                SC.GetValue<int>($"{Module}.Match.MFG") == (int)MatchMFG.AdTec)            {                _Match = DEVICE.GetDevice<AdTecMatch>($"{Module}.{VenusDevice.Match}");            }            else if (                SC.GetValue<int>($"{Module}.Match.MFG") == (int)MatchMFG.Revtech)            {                _Match = DEVICE.GetDevice<RevtechMatch>($"{Module}.{VenusDevice.Match}");            }            //if (SC.GetValue<bool>($"{Module}.BiasMatch.EnableBiasMatch") &&            //    SC.GetValue<int>($"{Module}.BiasMatch.CommunicationType") == (int)CommunicationType.RS232 &&            //    SC.GetValue<int>($"{Module}.BiasMatch.MFG") == (int)MatchMFG.AdTec)            //{            //    _BiasMatch = DEVICE.GetDevice<AdTecMatch>($"{Module}.{VenusDevice.BiasMatch}");            //}            //else if (SC.GetValue<bool>($"{Module}.BiasMatch.EnableBiasMatch") &&            //    SC.GetValue<int>($"{Module}.BiasMatch.MFG") == (int)MatchMFG.Revtech)            //{            //    _BiasMatch = DEVICE.GetDevice<RevtechMatch>($"{Module}.{VenusDevice.BiasMatch}");            //}            //if (SC.GetValue<bool>($"{Module}.RFBox.EnableMatch") &&            //   SC.GetValue<int>($"{Module}.RFBox.CommunicationType") == (int)CommunicationType.RS232 &&            //   SC.GetValue<int>($"{Module}.RFBox.MFG") == (int)MatchMFG.AdTec)            //{            //    _RFBox = DEVICE.GetDevice<AdTecMatch>($"{Module}.{VenusDevice.RFBox}");            //}            //else if (SC.GetValue<bool>($"{Module}.RFBox.EnableMatch") &&            //    SC.GetValue<int>($"{Module}.RFBox.MFG") == (int)MatchMFG.Revtech)            //{            //    _RFBox = DEVICE.GetDevice<RevtechMatch>($"{Module}.{VenusDevice.RFBox}");            //}            _foreline_interlock_pressure = SC.GetValue<int>($"{Module}.PendulumValve.ForelinePressureLimit");            _GasRFStopWatch.Stop();            processPressureLimit = 260;//unit Pa            _GasBoxN2FlowSwitchStopWatch.Start();            //_PressureType = (PressureType)SC.GetValue<int>("System.PressureUnitType");            DATA.Subscribe($"{Name}.PenningPressure", () => _pressureController.PenningGauge.Value);        }        #endregion        public async override void CloseValves(int? delayTime = null)        {            _PVN21Valve.TurnValve(false, out _);            // _PVN22Valve.TurnValve(false, out _);            _PV11Valve.TurnValve(false, out _);            _PV12Valve.TurnValve(false, out _);            _PV21Valve.TurnValve(false, out _);            _PV22Valve.TurnValve(false, out _);            _PV31Valve.TurnValve(false, out _);            _PV32Valve.TurnValve(false, out _);            _PV41Valve.TurnValve(false, out _);            _PV42Valve.TurnValve(false, out _);            //_PVHe1Valve.TurnValve(false, out _);            //_PVHe2Valve.TurnValve(false, out _);            _SoftPumpValve.TurnValve(false, out _);            _FastPumpValve.TurnValve(false, out _);            //_TurboPumpPumpingValve.TurnValve(false, out _);            _TurboPumpPurgeValve.TurnValve(false, out _);            //_GuageValve.TurnValve(false, out _);            _N2Valve.TurnValve(false, out _);            _O2Valve.TurnValve(false, out _);            //_N2Purge1Valve.TurnValve(false, out _);            _N2Purge2Valve.TurnValve(false, out _);            _FastPumpValve.TurnValve(false, out _);            _Mfc1Valve.TurnValve(false, out _);            _Mfc2Valve.TurnValve(false, out _);            _Mfc3Valve.TurnValve(false, out _);            _Mfc4Valve.TurnValve(false, out _);            _Mfc5Valve.TurnValve(false, out _);            _Mfc6Valve.TurnValve(false, out _);            _Mfc7Valve.TurnValve(false, out _);            _Mfc8Valve.TurnValve(false, out _);            foreach (var stick in _gasLines)            {                stick.Stop();            }            if (delayTime != null)            {                await Task.Delay((int)delayTime);            }            _GasFinalValve.TurnValve(false, out _);            _PurgeValve.TurnValve(false, out _);        }        public override void TurnDryPump(bool on)        {            //_pressureController.StartPump(on);            _MainPump?.SetPumpOnOff(on);        }        public override void TurnTurboPump(bool on)        {            _TurboPump?.SetPumpOnOff(on);        }        public override void OpenValve(ValveType vlvType, bool on)        {            switch (vlvType)            {                case ValveType.PVN21:                    _PVN21Valve.TurnValve(on, out _);                    break;                case ValveType.PVN22:                    _PVN22Valve.TurnValve(on, out _);                    break;                case ValveType.PV11:                    _PV11Valve.TurnValve(on, out _);                    break;                case ValveType.PV12:                    _PV12Valve.TurnValve(on, out _);                    break;                case ValveType.PV21:                    _PV21Valve.TurnValve(on, out _);                    break;                case ValveType.PV22:                    _PV22Valve.TurnValve(on, out _);                    break;                case ValveType.PV31:                    _PV31Valve.TurnValve(on, out _);                    break;                case ValveType.PV32:                    _PV32Valve.TurnValve(on, out _);                    break;                case ValveType.PV41:                    _PV41Valve.TurnValve(on, out _);                    break;                case ValveType.PV42:                    _PV42Valve.TurnValve(on, out _);                    break;                case ValveType.N2:                    _N2Valve.TurnValve(on, out _);                    break;                case ValveType.Purge:                    _PurgeValve.TurnValve(on, out _);                    break;                case ValveType.GasFinal:                    _GasFinalValve.TurnValve(on, out _);                    break;                case ValveType.SoftPump:                    _SoftPumpValve.TurnValve(on, out _);                    break;                case ValveType.FastPump:                    _FastPumpValve.TurnValve(on, out _);                    break;                case ValveType.TurboPumpPumping:                    _TurboPumpPumpingValve.TurnValve(on, out _);                    break;                case ValveType.TurboPumpPurge:                    _TurboPumpPurgeValve.TurnValve(on, out _);                    break;                case ValveType.Guage:                    _GuageValve.TurnValve(on, out _);                    break;                //case ValveType.LoadlockVent:                //    _LoadlockVentValve.TurnValve(on, out _);                //    break;                //case ValveType.LoadlockPumping:                //    _LoadlockPumpingValve.TurnValve(on, out _);                //    break;                case ValveType.Mfc1:                    _Mfc1Valve.TurnValve(on, out _);                    break;                case ValveType.Mfc2:                    _Mfc2Valve.TurnValve(on, out _);                    break;                case ValveType.Mfc3:                    _Mfc3Valve.TurnValve(on, out _);                    break;                case ValveType.Mfc4:                    _Mfc4Valve.TurnValve(on, out _);                    break;                case ValveType.Mfc5:                    _Mfc5Valve.TurnValve(on, out _);                    break;                case ValveType.Mfc6:                    _Mfc6Valve.TurnValve(on, out _);                    break;                case ValveType.Mfc7:                    _Mfc7Valve.TurnValve(on, out _);                    break;                case ValveType.Mfc8:                    _Mfc8Valve.TurnValve(on, out _);                    break;                case ValveType.O2:                    _O2Valve.TurnValve(on, out _);                    break;                case ValveType.N2Purge1:                    _N2Purge1Valve.TurnValve(on, out _);                    break;                case ValveType.N2Purge2:                    _N2Purge2Valve.TurnValve(on, out _);                    break;                case ValveType.PenningGauge:                    _PenningGuageValve.TurnValve(on, out _);                    break;                    //default:                    //    throw new ArgumentOutOfRangeException($"Argument error {vlvType}-{on}");            }        }        public override void Monitor()        {            CheckScrubber();            foreach (var gas in _gasLines)            {                gas.Monitor();            }            CheckPermanentInterlock();            //if (_GasBoxN2FlowSwitchStopWatch.ElapsedMilliseconds > 10 * 1000)            //{            //    _GasBoxN2FlowSwitchStopWatch.Stop();            //}            CheckHighTemperatureHeaterInterlock();        }        private void CheckScrubber()        {            ScrubberTrigger.CLK = ScrubberIsOK;            if (ScrubberTrigger.Q)            {                _scrubberMode = (ScrubberMode)SC.GetValue<int>($"{Module}.ScrubberMode");                switch (_scrubberMode)                {                    case ScrubberMode.Warning:                        LOG.Write(eEvent.WARN_PM_SCRUBBER_NOOK, Module, $"{Module} Scrubber Warning");                        break;                    case ScrubberMode.StopTransferStopProcess:                        LOG.Write(eEvent.ERR_PM_SCRUBBER_NOOK_STOPPROCESS, Module, $"{Module} Scrubber Alarm,Stop Process if Processing,Switch to Offline");                        break;                    case ScrubberMode.StopTranferContinueProcess:                        LOG.Write(eEvent.ERR_PM_SCRUBBER_NOOK_CONTINUEPROCESS, Module, $"{Module} Scrubber Alarm,Continue Process if Processing,Switch to Offline");                        break;                }            }              }        private void CheckHighTemperatureHeaterInterlock()        {            if (_highTemperatureHeater.HighTemperatureHeaterIsOn == false)            {                return;            }            if (_GasBoxN2Flow_sw.Value)            {                _GasBoxN2FlowSwitchStopWatch.Reset();            }            else            {                _GasBoxN2FlowSwitchStopWatch.Start();            }            if (_GasBoxN2FlowSwitchStopWatch.ElapsedMilliseconds > 10 * 1000 && _GasBoxN2FlowSwitchStopWatch.IsRunning)            {                _GasBoxN2FlowSwitchStopWatch.Reset();                var limitTemperature = SC.GetValue<double>($"{Module}.HighTemperatureHeater.N2WarningTemperatureLimit");                if (limitTemperature < ChamberTemperature)                {                    SetHighTemperatureHeaterTemperature((int)limitTemperature);                    LOG.Write(eEvent.WARN_DEVICE_INFO, Module, $"Gas Box N2 Flow Trigger Warning,HighTemperatureHeater Cool Down to {limitTemperature} ℃,Current Purge N2 Flow {_highTemperatureHeater.HighTemperatureHeaterN2Flow}");                }            }        }        protected override void CheckPermanentInterlock()        {            if (ChamberPressure >= processPressureLimit && _GuageValve.SetPoint)            {                _GuageValve.TurnValve(false, out _);                LOG.Write(eEvent.WARN_DEVICE_INFO, Module, $"Process pressure:{ChamberPressure} exceed {processPressureLimit} Pa, Guage Valve (DO-31) closed automaticlly.");            }            if (ChamberPressure < processPressureLimit && !_GuageValve.SetPoint)            {                _GuageValve.TurnValve(true, out _);                LOG.Write(eEvent.WARN_DEVICE_INFO, Module, $"Process pressure:{ChamberPressure} less than {processPressureLimit} Pa, Guage Valve (DO-31) open automaticlly.");            }        }        public override async void CheckIdleInterlock(int delaytime)        {            if (ForelinePressure > _foreline_interlock_pressure)            {                await Task.Delay(500);                if (ForelinePressure < _foreline_interlock_pressure)                {                    return;                }                if (_TurboPumpPumpingValve.SetPoint || _TurboPumpPurgeValve.SetPoint || _pendulumValve.IsOpen)                {                    _pendulumValve.TurnValve(false);                    _TurboPumpPurgeValve.TurnValve(false, out _);                    _TurboPumpPumpingValve.TurnValve(false, out _);                    LOG.Write(eEvent.WARN_DEVICE_INFO, Module, $"Foreline pressure:{ForelinePressure} exceed {_foreline_interlock_pressure} Pa, Pendulum valve & PV6 & PV7 closed automaticlly.");                }            }            if (_TurboPumpPumpingValve.SetPoint == false && _pendulumValve.IsOpen)            {                _pendulumValve.TurnValve(false);                LOG.Write(eEvent.WARN_DEVICE_INFO, Module, $"ISO Valve Closed, Pendulum valve  closed automaticlly.");            }        }        public override void Home()        {            _Generator?.ReConnect();            _Match?.ReConnect();            _MainPump?.ReConnect();            _TurboPump?.ReConnect();            _pendulumValve?.ReConnect();        }        public override bool HomeIsOK(out string reason)        {            if (!IsSlitDoorClosed)            {                reason = "Door is not Close";                return false;            }            if (!_highTemperatureHeater.LiftIsOK())            {                reason = "HighTemperatureHeater Lift is not OK";                return false;            }            if (SC.GetValue<bool>($"{Module}.{VenusDevice.PendulumValve}.NoCheck"))            {                reason = "PendulumValve No Check is not Close";                return false;            }            reason = "";            return true;        }        public override bool FlowGas(int gasNum, double val)        {            if (_gasLines.Length <= gasNum)                return false;            //double value = (val / _gasLines[gasNum]._mfc.Scale) * 100;            //double setPoint =Math.Round( value / 8000 * _gasLines[gasNum]._mfc.Scale,2);            _gasLines[gasNum].Flow(val);            return true;        }        public override bool PumpGas(int gasNum)        {            if (_gasLines.Length <= gasNum)                return false;            switch (gasNum)            {                case 0:                    OpenValve(ValveType.PV12, true);                    break;                case 1:                    OpenValve(ValveType.PV22, true);                    break;                case 2:                    OpenValve(ValveType.PV32, true);                    break;                case 3:                    OpenValve(ValveType.PV42, true);                    break;            }            _gasLines[gasNum].Pump();            OpenValve(ValveType.N2Purge2, true);            return true;        }        public override bool PurgeGas(int gasNum)        {            if (_gasLines.Length <= gasNum)                return false;            switch (gasNum)            {                case 0:                    OpenValve(ValveType.PV12, true);                    break;                case 1:                    OpenValve(ValveType.PV22, true);                    break;                case 2:                    OpenValve(ValveType.PV32, true);                    break;                case 3:                    OpenValve(ValveType.PV42, true);                    break;            }            _gasLines[gasNum].Pump();            OpenValve(ValveType.PVN21, true);            return true;        }        public override bool StopGas(int gasNum)        {            if (_gasLines.Length <= gasNum)                return false;            _gasLines[gasNum].Stop();            return true;        }        public override bool FlowN2(double val)        {            _gasLineN2.Flow(val);            return true;        }        public override bool StopN2()        {            _gasLineN2.Stop();            return true;        }        public override void StopAllGases()        {            foreach (var line in _gasLines)            {                line.Stop();            }        }        public override bool TurnPendulumValve(bool on)        {            return _pendulumValve.TurnValve(on);        }        public override bool SetPVPressure(float pressure)        {            return _pendulumValve.SetPressure(pressure);        }        public override bool SetPVPostion(float position)        {            return _pendulumValve.SetPosition(position);        }        public override float GetPVPosition()        {            return _pendulumValve.Position;        }        public override void SetGeneratorCommunicationMode(int mode)        {            _Generator?.SetCommunicationMode(mode);        }        public override bool GeneratorPowerOn(bool on)        {            if (_Generator == null) return false;            if (on && !IsRFGInterlockOn)            {                LOG.Write(eEvent.ERR_RF_RFGInterlock, Module, "射频电源 Interlock条件不满足");                return false;            }            if (on && !_TopShieldCoverClosedAlarm.Value)            {                LOG.Write(eEvent.ERR_RF, Module, "DI-21 Top Shield Cover closed alarm,射频条件不满足");                return false;            }            return _Generator.SetPowerOnOff(on, out _);        }        public override bool GeneratorSetpower(float val)        {            if (_Generator == null) return false;            if (Math.Abs(val) > 0.01)                _Generator.SetPower((ushort)val);            return true;        }        //public override bool SetRFBoxC1Position(float c1)        //{        //    if (_RFBox == null) return false;        //    _RFBox.SetMatchPositionC1(c1, out _);        //    return true;        //}        public override bool SetWallTCTemperature(float value)        {            return _WallTC.RampTemp(value);        }        public override bool SetMatchPosition(float c1, float c2)        {            if (_Match == null) return false;            string reason = string.Empty;            _Match.SetMatchPosition(c1, c2, out reason);            return true;        }        public override bool SetMatchWorkMode(MatchWorkMode matchWorkMode)        {            if (_Match == null) return false;            if (matchWorkMode == MatchWorkMode.Auto)            {                return _Match.SetMatchMode(EnumRfMatchTuneMode.Auto, out _);            }            else if (matchWorkMode == MatchWorkMode.Manual)            {                return _Match.SetMatchMode(EnumRfMatchTuneMode.Manual, out _);            }            return false;        }        public override bool CheckGeneratorAndHVInterlock(VenusDevice device)        {            eEvent evt = device == VenusDevice.Rf ? eEvent.ERR_RF : eEvent.ERR_ESC_HV;            if (!IsLidClosed)            {                LOG.Write(evt, Module, $"Cannot Power ON {device} as PM Lid is Open.");                return false;            }            if (!IsVAC)            {                LOG.Write(evt, Module, $"Cannot Power ON {device} as PM is not Vacuum.");                return false;            }            if (!IsWaterFlowOk)            {                LOG.Write(evt, Module, $"Cannot Power ON {device} as Water Flow is OFF.");                return false;            }            if (!IsRFGInterlockOn)            {                LOG.Write(evt, Module, $"Cannot Power ON {device} as Generator Interlock is OFF.");                return false;            }            if (!SlitDoorClosed)            {                LOG.Write(evt, Module, $"Cannot Power ON {device} as Slit Door is open.");                return false;            }            return true;        }        public override bool StartControlPressure(int pressureSetpoint, int flowSetpoint)        {            OpenValve(ValveType.Purge, true);            //OpenValve(ValveType.N2, true);            OpenValve(ValveType.PVN22, true);            OpenValve(ValveType.GasFinal, false);            OpenValve(ValveType.TurboPumpPumping, true);            if (_pendulumValve.IsOpen == false)            {                TurnPendulumValve(true);            }            SetPVPressure(pressureSetpoint);            return true;        }        public async override void AbortControlPressure()        {            //OpenValve(ValveType.N2, false);            OpenValve(ValveType.PVN22, false);            OpenValve(ValveType.TurboPumpPumping, true);            //SetPVPressure(0);            TurnPendulumValve(true);            //SetPVPostion(1000);            await Task.Delay(0);            OpenValve(ValveType.Purge, false);            //return true;        }        public override bool HighTemperatureHeaterGotoPosition(HighTemperatureHeaterPosition highTemperatureHeaterPosition)        {            return _highTemperatureHeater.GotoPosition(highTemperatureHeaterPosition);        }        public override bool SetHighTemperatureHeaterTemperature(int temperature)        {            _highTemperatureHeater.HighTemperatureHighHeaterTemperature = temperature;            return true;        }        public override bool SetHighTemperatureHeaterRatio(int ratio)        {            _highTemperatureHeater.HighTemperatureHeaterRatio = ratio;            return true;        }        public override bool PreparePlace()        {            //if (!SetSlitDoor(true, out string reason))            //{            //    LOG.Write(eEvent.ERR_PM, Module, $"Set Slit Door Open failed:{reason}");            //    return false;            //}            return _highTemperatureHeater.GotoPosition(HighTemperatureHeaterPosition.Position1);        }        public override bool PreparePick()        {            //if (!SetSlitDoor(true, out string reason))            //{            //    LOG.Write(eEvent.ERR_PM, Module, $"Set Slit Door Open failed:{reason}");            //    return false;            //}            return _highTemperatureHeater.GotoPosition(HighTemperatureHeaterPosition.Position1);        }        public override bool PreparePlaceIsOK()        {            return _highTemperatureHeater.CurrentPosition == HighTemperatureHeaterPosition.Position1 && _WaferTransferPosi_sw.Value;        }        public override bool PreparePickIsOK()        {            return _highTemperatureHeater.CurrentPosition == HighTemperatureHeaterPosition.Position1 && _WaferTransferPosi_sw.Value;        }        public override bool EndPlace()        {            //if (!SetSlitDoor(false, out string reason))            //{            //    LOG.Write(eEvent.ERR_PM, Module, $"Set Slit Door Close failed:{reason}");            //    return false;            //}            if (!_highTemperatureHeater.GotoPosition(HighTemperatureHeaterPosition.Position2))            {                LOG.Write(eEvent.ERR_HighTemperatureHeater, Module, $"Set High Temperature Heater To Position2 failed");                return false;            }            return true;        }        public override bool EndPick()        {            //if (!SetSlitDoor(false, out string reason))            //{            //    LOG.Write(eEvent.ERR_PM, Module, $"Set Slit Door Close failed:{reason}");            //    return false;            //}            return true;        }        public override bool EndPlaceIsOK()        {            return _highTemperatureHeater.CurrentPosition == HighTemperatureHeaterPosition.Position2;        }        public override bool EndPickIsOK()        {            return CheckSlitDoorClose();        }        public override void RTCloseEvent()        {            if (_Generator.IsPowerOn)            {                GeneratorPowerOn(false);            }            if (PendulumValveIsOpen())            {                TurnPendulumValve(false);            }        }        public override bool RFInterlock(VenusDevice device)        {            eEvent evt = eEvent.ERR_RF;            if (!IsWaterFlowOk)            {                LOG.Write(evt, Module, $"Cannot Power ON {device} as Water Flow is OFF.");                return false;            }            if (!IsRFGInterlockOn)            {                LOG.Write(evt, Module, $"Cannot Power ON {device} as Generator Interlock is OFF.");                return false;            }            if (GasIsOff())            {                LOG.Write(evt, Module, $"Cannot Power ON {device} as Gas is OFF.");                return false;            }            return true;        }        private bool GasIsOff()        {            if ((IsMfc1ValveOpened == false && IsMfc2ValveOpened == false && IsMfc3ValveOpened == false && IsMfc4ValveOpened == false && IsMfc5ValveOpened == false && IsMfc6ValveOpened == false && IsMfc7ValveOpened == false && IsMfc8ValveOpened == false && _GasFlag == false) || (MFC1FeedBack < 1 && MFC2FeedBack < 1 && MFC3FeedBack < 1 && MFC4FeedBack < 1 && MFC5FeedBack < 1 && MFC6FeedBack < 1 && MFC7FeedBack < 1 && MFC8FeedBack < 1 && _GasFlag == false))            {                if (_GasRFStopWatch.IsRunning == false)                {                    _GasRFStopWatch.Start();                }                if (_GasRFStopWatch.ElapsedMilliseconds > 1500 && _GasRFStopWatch.ElapsedMilliseconds < 2500)                {                    //var item = _GasRFStopWatch.ElapsedMilliseconds;                    _GasRFStopWatch.Reset();                    _GasFlag = true;                    return true;                }            }            else            {                _GasRFStopWatch.Reset();                _GasFlag = false;            }            return false;        }        public override void PMInError()        {            CloseValves();            GeneratorPowerOn(false);            GeneratorBiasPowerOn(false);        }    }}
 |