| 123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182183184185186187188189190191192193194195196197198199200201202203204205206207208209210211212213214215216217218219220221222223224225226227228229230231232233234235236237238239240241242243244245246247248249250251252253254255256257258259260261262263264265266267268269270271272273274275276277278279280281282 | using Aitex.Core.Common.DeviceData;using Aitex.Core.RT.Device;using Aitex.Core.RT.Log;using Aitex.Core.RT.SCCore;using Aitex.Core.RT.Tolerance;using Aitex.Core.Util;using MECF.Framework.Common.Communications;using MECF.Framework.Common.Equipment;using MECF.Framework.Common.Utilities;using System;using System.Collections.Concurrent;using System.Collections.Generic;using System.Linq;using System.Reflection;using System.Text;using System.Threading.Tasks;using static Mono.Security.X509.X520;using Venus_Core;using System.Diagnostics;namespace Venus_RT.Devices{    /// <summary>    /// 描述:该类用于对单Chiller Controller下多设备共享 的驱动 只单一的用于串口的连接    /// 需要存储的变量及说明    /// Statusflag:与chiller的开关有关    /// Alarmflag: 报警    /// chillerIsOn:正在进行    /// ControlTcFeedback:返回值    /// </summary>    public enum ChillerMsgType    {        Get,        Set    }    public class SMCChillerDrive    {        public SMCChillerState StatusSMC { get; set; }        private readonly string _PortNum = "COM92";        private readonly AsyncSerialPort _serial;        BlockingCollection<string> blockingCollection = new BlockingCollection<string>();        public string PortName => _PortNum;        private Dictionary<string,string> _address2Module;//不正确 应该以字典的形式 以头去打印        private Dictionary<string, ChillerData> _addressQuery;        private Dictionary<string, Queue<string>> _addressCmdQueue;        private ModuleName Module;//不正确 应该以字典的形式 以头去打印        // --------------------------Constructor-----------------------        //        public SMCChillerDrive(string Port)        {            _PortNum = Port;            StatusSMC = SMCChillerState.Unknown;            _serial = new AsyncSerialPort(_PortNum, 9600, 7, System.IO.Ports.Parity.Even, System.IO.Ports.StopBits.One, "\r\n", true);            if (!_serial.Open())            {                StatusSMC = SMCChillerState.Disconnected;                LOG.Write(eEvent.ERR_DEVICE_CHILLER, ModuleName.System, $"SMC Chiller串口:{_PortNum}无法打开");            }            StatusSMC = SMCChillerState.Connected;            _serial.OnDataChanged += OnPortDataChanged;            _serial.OnErrorHappened += OnErrorOccurred;            _address2Module = new Dictionary<string, string>();            _addressQuery = new Dictionary<string, ChillerData>();            _addressCmdQueue = new Dictionary<string, Queue<string>>();            Task.Run(() =>            {                foreach (var data in blockingCollection.GetConsumingEnumerable())                {                    _serial?.Write(data);                    System.Threading.Thread.Sleep(500);                }            });        }        private void OnPortDataChanged(string obj)        {            try            {                if (SC.GetValue<bool>("System.IsSimulatorMode"))                {                    //Statusflag[0] = true;                    //if (_controlTcSetPoint <= SetPointLimitMax / 2 && _controlTcSetPoint >= SetPointLimitMin)                    //    _controlTcFeedback = _controlTcSetPoint;                    return;                }                if (string.IsNullOrEmpty(obj))                {                    LOG.Write(eEvent.ERR_DEVICE_CHILLER, ModuleName.System, $"[{_PortNum}] smc chiller message IsNullOrEmpty");                    return;                }                string cmd = obj.Split(new char[] { '\r', '\n' })[0];                //若为system或null 说明dic中无value或value无效                //Debug.Assert(chillerData != null && module != ModuleName.System);                if (ModbusUtility.CalculateLrc(ModbusUtility.HexToBytes(cmd.Substring(1, cmd.Length - 3))).ToString("X2") !=                    cmd.Substring(cmd.Length - 2))  //LRC check                {                    LOG.Write(eEvent.ERR_DEVICE_CHILLER, Module, $"[{_PortNum}] smc chiller message LRC check error");                    return;                }                //注意 数据开头有":"                //地址位 决定了是哪个chamber的哪个type                ModuleName module = ModuleName.System;                //LOG.Write(eEvent.INFO_DEVICE_CHILLER, ModuleName.System, $"[{_PortNum}] smc chiller receive message {cmd}");                string header = cmd.Substring(1, 2);                if (_address2Module.ContainsKey(header) && _addressQuery.ContainsKey(header))                {                    module = ModuleHelper.Converter(_address2Module[header].Split('.')[0]);                    //LOG.Write(eEvent.INFO_DEVICE_CHILLER, ModuleName.System, $"[{_PortNum}] smc chiller know module:{_address2Module[cmd.Substring(1, 2)]},{cmd.Substring(1, 2)}");                }                else                {                    LOG.Write(eEvent.ERR_DEVICE_CHILLER, ModuleName.System, $"[{_PortNum}]:address => {header} not in Dictionary");                    return;                }                switch (cmd.Substring(3, 2))    //function code                {                    case "03":  //返回的寄存器内容                        if (cmd.Substring(5, 2) == "16")    //返回了全部11个寄存器、22个Byte数据                        {                            ChillerData chillerdata = new ChillerData();                            for (int iRegisterNo = 0; iRegisterNo < 11; iRegisterNo++)                            {                                string sBuf = cmd.Substring(4 * iRegisterNo + 7, 4);                                int iBuf = 0;                                for (int i = 3; i > -1; i--)                                {                                    iBuf += Convert.ToInt32(sBuf.Substring(i, 1), 16) * (int)Math.Pow(16, 3 - i);                                }                                switch (iRegisterNo)                                {                                    case 0:     //Circulating fluid discharge temperature                                        chillerdata.ControlTcFeedback = (float)iBuf / 10;                                        break;                                    case 4:     //Status flag 1                                        for (int i = 0; i < 16; i++)                                        {                                            chillerdata.Statusflag[i] = Convert.ToBoolean((int)Math.Pow(2, i) & iBuf);                                        }                                        break;                                    case 5:     //Alarm flag 1                                        for (int i = 0; i < 16; i++)                                        {                                            chillerdata.Alarmflag[i] = Convert.ToBoolean((int)Math.Pow(2, i) & iBuf);                                        }                                        break;                                    case 6:     //Alarm flag 2                                        for (int i = 0; i < 16; i++)                                        {                                            chillerdata.Alarmflag[i + 16] = Convert.ToBoolean((int)Math.Pow(2, i) & iBuf);                                        }                                        break;                                    case 7:     //Alarm flag 3                                        for (int i = 0; i < 16; i++)                                        {                                            chillerdata.Alarmflag[i + 32] = Convert.ToBoolean((int)Math.Pow(2, i) & iBuf);                                        }                                        break;                                    case 9:     //Status flag 2                                        for (int i = 0; i < 16; i++)                                        {                                            chillerdata.Statusflag[i + 16] = Convert.ToBoolean((int)Math.Pow(2, i) & iBuf);                                        }                                        break;                                }                            }                            _addressCmdQueue[header].Dequeue();                            _addressQuery[header] = chillerdata;                        }                        break;                    case "06":  //寄存器的写成功消息                        break;                }            }            catch (Exception ex)            {                LOG.Write(eEvent.ERR_DEVICE_CHILLER, ModuleName.System, $"[{_PortNum}] smc chiller error: [{ex.Message}]");            }        }        private void OnErrorOccurred(string obj)        {            StatusSMC = SMCChillerState.ERROR;            LOG.Write(eEvent.ERR_DEVICE_CHILLER, ModuleName.System, $"[{_PortNum}] smc chiller error: [{obj}]");        }        public void SendCmd(ChillerMsgType type,string str)        {            //消息通用格式:开头 + 内容 + LRC + 结尾            //_serial?.Write(":" + str + ModbusUtility.CalculateLrc(ModbusUtility.HexToBytes(str)).ToString("X2") + "\r\n");            //如果是设置的直接发出无需等待            if (type == ChillerMsgType.Set)            {                blockingCollection.Add(":" + str + ModbusUtility.CalculateLrc(ModbusUtility.HexToBytes(str)).ToString("X2") + "\r\n");            }            //如果是获取的可以慢一些 在数据回复后继续            if (type == ChillerMsgType.Get)            {                //每interval获取温度 超过一秒时效性失去意义 500 * 2积累太多数据 同时注意其是与monitor紧密联系的 实际上是每interval就会进来可能导致数组变大                //因此每次进来要控制规模 > 2 时 实时性已经失去此时应该等待回复并把头前的清除掉 而且要注意 chiller本身升温很慢 界面上ramp不明显                _addressCmdQueue[str.Substring(0, 2)].Enqueue(str);                if (_addressCmdQueue[str.Substring(0, 2)].Count > 1)                    _addressCmdQueue[str.Substring(0, 2)].Dequeue();                else                    blockingCollection.Add(":" + _addressCmdQueue[str.Substring(0, 2)].Peek() + ModbusUtility.CalculateLrc(ModbusUtility.HexToBytes(str)).ToString("X2") + "\r\n");            }        }        public void AddAddress(string address, string chillertype)        {            //address => "02" chillertype => PMA.OutChiller            _address2Module.Add(address,chillertype);            _addressQuery.Add(address, new ChillerData());            _addressCmdQueue.Add(address, new Queue<string>());        }        public ChillerData QueryData(string address)        {            if (_addressQuery.ContainsKey(address))            {                return _addressQuery[address];            }            else            {                LOG.Write(eEvent.ERR_DEVICE_CHILLER, ModuleName.System, $"[{_PortNum}] => address:{address} not exist");                return null;            }        }        public void Terminate()        {            _serial?.Close();        }    }    public class ChillerData    {        public bool[] Statusflag {get; set;}        public bool[] Alarmflag { get; set; }        public float ControlTcFeedback { get; set; }        public ChillerData()        {            Statusflag = new bool[32];            Alarmflag = new bool[48];            ControlTcFeedback = 0.0f;        }    }}
 |