| 123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138 | 
							- using Aitex.Core.RT.Routine;
 
- using Aitex.Core.RT.SCCore;
 
- using Venus_RT.Devices;
 
- using MECF.Framework.Common.Routine;
 
- using Venus_Core;
 
- using Aitex.Core.RT.DataCenter;
 
- namespace Venus_RT.Modules.PMs
 
- {
 
-     class VentRoutine : PMRoutineBase, IRoutine
 
-     {
 
-         private enum VentStep
 
-         {
 
-             kISODelay,
 
-             kClosePVValves,
 
-             kClosePVValveDelay,
 
-             KCloseTurboPurgeValve,
 
-             KCloseISOValve,
 
-             kOpenVentValves,
 
-             kDelay_2,
 
-             kCloseVentValves,
 
-         }
 
-         //private int _ventTime;
 
-         private int _ventTimeDelay = 1;
 
-         private int _checkATMTimeout = 90;
 
-         public bool VentingFlag => _ventingflag;
 
-         private bool _ventingflag = false;
 
-         public VentRoutine(JetPMBase chamber) : base(chamber)
 
-         {
 
-             Name = "PM Vent";
 
-         }
 
-         public RState Start(params object[] objs)
 
-         {
 
-             if (CheckLid() &&
 
-                 CheckSlitDoor() &&
 
-                 CheckCDA() &&
 
-                 CheckATM())
 
-             {
 
-                 Reset();
 
-                 _chamber.CloseValves();
 
-                 //_chamber.OpenValve(ValveType.TurboPumpPumping, true);
 
-                 //_chamber.OpenValve(ValveType.TurboPumpPurge, true);
 
-                 //_chamber.OpenValve(ValveType.PVN22, true);
 
-                 //_chamber.OpenValve(ValveType.N2, true);
 
-                 //_chamber.OpenValve(ValveType.GasFinal, true);
 
-                 _checkATMTimeout = SC.GetValue<int>($"{Module}.CheckATMTimeout");
 
-                 _ventTimeDelay = SC.GetValue<int>($"{Module}.OverVentTime");
 
-                 if (Runner.Start(Module, Name) == RState.Running)
 
-                 {
 
-                     _ventingflag = true;
 
-                     return RState.Running;
 
-                 }
 
-                 else
 
-                 {
 
-                     _ventingflag = false;
 
-                     return RState.Failed;
 
-                 }
 
-             }
 
-             return RState.Failed;
 
-         }
 
-         public RState Monitor()
 
-         {
 
-           Runner
 
-                 .Run(VentStep.kClosePVValves,   ClosePVValves,    PVIsOpen)
 
-                 .Delay(VentStep.kClosePVValveDelay, _delay_2s)
 
-                 .Run(VentStep.KCloseTurboPurgeValve, HOFs.WrapAction(_chamber.OpenValve, ValveType.TurboPumpPurge, false),    _delay_1s)
 
-                 .Run(VentStep.KCloseISOValve, HOFs.WrapAction(_chamber.OpenValve, ValveType.TurboPumpPumping, false), _delay_1s)
 
-                 .Run(VentStep.kOpenVentValves,  OpenValve,       () => { return _chamber.IsATM; }, _checkATMTimeout * 1000)
 
-                 .Delay(VentStep.kDelay_2,       _ventTimeDelay)
 
-                 .End(VentStep.kCloseVentValves, CloseVentGasFinalValves, _delay_2s);
 
-             _ventingflag = Runner.Status == RState.Running;
 
-             return Runner.Status;
 
-         }
 
-         private bool ClosePVValves()
 
-         {
 
-             _chamber.OpenValve(ValveType.Guage, false);
 
-             if (_chamber.PendulumValveIsOpen())
 
-             {
 
-                 return _chamber.TurnPendulumValve(false);
 
-             }
 
-             _chamber.OpenValve(ValveType.TurboPumpPumping, false);
 
-             _chamber.OpenValve(ValveType.TurboPumpPurge, false);
 
-             _chamber.OpenValve(ValveType.FastPump, false);
 
-             _chamber.OpenValve(ValveType.SoftPump, false);
 
-             return true;
 
-         }
 
-         private bool PVIsOpen()
 
-         {
 
-             return !_chamber.PendulumValveIsOpen();
 
-         }
 
-         private bool OpenValve()
 
-         {
 
-             if (_chamber.ChamberType == JetChamber.VenusSE || _chamber.ChamberType == JetChamber.VenusDE)
 
-             {
 
-                 _chamber.OpenValve(ValveType.PVN22, true);
 
-             }
 
-             _chamber.OpenValve(ValveType.PVN22, true);
 
-             _chamber.OpenValve(ValveType.N2, true);
 
-             _chamber.OpenValve(ValveType.GasFinal, true);
 
-             return true;
 
-         }
 
-         private bool CloseVentGasFinalValves()
 
-         {
 
-             //if (_chamber.ChamberType == JetChamber.VenusSE || _chamber.ChamberType == JetChamber.VenusDE)
 
-             //{
 
-             //    _chamber.OpenValve(ValveType.PVN22, false);
 
-             //}
 
-             _chamber.OpenValve(ValveType.GasFinal, false);
 
-             _chamber.OpenValve(ValveType.N2, false);
 
-             _chamber.OpenValve(ValveType.PVN22, false);
 
-             return true;
 
-         }
 
-         public void Abort()
 
-         {
 
-             CloseAllValves();
 
-         }
 
-     }
 
- }
 
 
  |