123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182183184185186187188189190191192193194195196197198199200201202203204205206207208209210211212213214215216217218219220221222223224225226227228229230231232233234235236237238239240241242243244245246247248249250251252253254255256257258259260261262263264265266267268269270271272273274275276277278279280281282283284285286287288289290291292293294295296297298299300301302303304305306307308309310311312313314315316317318319320321322323324325326327328329330331332333334335336337338339340341342343344345346347348349350351352353354355356357358359360361362363364365366367368369370371372373374375376377378379380381382383384385386387388389390391392393394395396397398399400401402403404405406407408409410411412413414415416417418419420421422423424425426427428429430431432433434435436437438439440441442443444445446447448449450451452453454455456457458459460461462463464465466467468469470471472473474475476477478479480481482483484485486487488489490491492493494495496497498499500501502503504505506507508509510511512513514515516517518519520521522523524525526527528529530531532533534535536537538539540541542543544545546547548549550551552553554555556557558559560561562563564565566567568569570571572573574575576577578579580581582583584585586587588589590591592593594595596597598599600601602603604605606607608609610611612613614615616617618619620621622623624625626627628629630631632633634635636637638639640641642643644645646647648649650651652653654655656657658659660661662663 |
- using Aitex.Core.RT.DataCenter;
- using Aitex.Core.RT.Device;
- using Aitex.Core.RT.Log;
- using Aitex.Core.RT.OperationCenter;
- using Aitex.Core.RT.Routine;
- using Aitex.Core.RT.SCCore;
- using Aitex.Core.Util;
- using MECF.Framework.Common.Algorithm;
- using MECF.Framework.Common.Beckhoff.ModuleIO;
- using MECF.Framework.Common.CommonData.Prewet;
- using MECF.Framework.Common.Persistent.Prewet;
- using MECF.Framework.Common.TwinCat;
- using CyberX8_Core;
- using System;
- using System.Collections.Generic;
- using System.Reflection;
- using CyberX8_RT.Modules;
- using CyberX8_RT.Modules.Prewet;
- using CyberX8_RT.Modules.Metal;
- using MECF.Framework.Common.Persistent.Temperature;
- using MECF.Framework.Common.IOCore;
- namespace CyberX8_RT.Devices.Prewet
- {
- public class PrewetDevice : BaseDevice, IDevice
- {
- private enum PrewetOperation
- {
- None,
- PumpEnable,
- PumpDisable
- }
- #region 常量
- private const string PUMP_VALVE = "PumpValve";
- private const string PUMP_ENABLE = "PumpEnable";
- private const string PUMP_SPEED = "PumpSpeed";
- private const string PUMP_STAUS = "PumpStatus";
- private const string PUMP_CURRENT = "PumpCurrent";
- private const string PUMP_FLOW = "PumpFlow";
- private const string PUMP_PRESSURE = "PumpPressure";
- private const string PUMP_DATA = "PumpData";
- private const string PERSISTENT_VALUE = "PersistentValue";
- #endregion
- #region 内部变量
- /// <summary>
- /// 数据
- /// </summary>
- private PrewetPumpData _prewetPumpData=new PrewetPumpData();
- /// <summary>
- /// pdi控制中的p
- /// </summary>
- private double _pumpKp;
- /// <summary>
- /// pdi控制中的i
- /// </summary>
- private double _pumpKi;
- /// <summary>
- /// pdi控制中的d
- /// </summary>
- private double _pumpKd;
- /// <summary>
- /// 操作当前状态
- /// </summary>
- private RState _status;
- /// <summary>
- /// 当前操作
- /// </summary>
- private PrewetOperation _currentOperation;
- /// <summary>
- /// Prewet 持久性数值对象
- /// </summary>
- private PrewetPersistentValue _prewetPersistentValue;
- /// <summary>
- /// Pump Enable routine
- /// </summary>
- private PrewetPumpEnableRoutine _prewetPumpEnableRoutine;
- /// <summary>
- /// Pump Disable routine
- /// </summary>
- private PrewetPumpDisableRoutine _prewetPumpDisableRoutine;
- /// <summary>
- /// 上一次Pump速度
- /// </summary>
- private short _lastPumpSpeed;
- /// <summary>
- /// 变量是否初始化字典
- /// </summary>
- private Dictionary<string, bool> _variableInitializeDic = new Dictionary<string, bool>();
- /// <summary>
- /// 定时器Job
- /// </summary>
- PeriodicJob _periodicJob = null;
- /// <summary>
- /// Run recipe total time
- /// </summary>
- public int _runRecipeTotalTime;
- #endregion
- #region 属性
- /// <summary>
- /// Pump 数据
- /// </summary>
- public PrewetPumpData PrewetPumpData { get { return _prewetPumpData; } }
- /// <summary>
- /// 操作当前状态
- /// </summary>
- public RState Status { get { return _status; } }
- /// <summary>
- /// 所有io变量是否初始化
- /// </summary>
- public bool IOInitialized { get { return AllIoVariableInitialized(); } }
- /// <summary>
- /// Last Pump Speed
- /// </summary>
- public short LastPumpSpeed { get { return _lastPumpSpeed; } }
- /// 是否启动调速
- /// </summary>
- public bool IsStartAutoSpeed { get; set; }
- #endregion
- /// <summary>
- /// 构造函数
- /// </summary>
- /// <param name="moduleName"></param>
- /// <param name="name"></param>
- public PrewetDevice(string moduleName) : base(moduleName, moduleName,moduleName,moduleName)
- {
- _prewetPumpData = new PrewetPumpData();
- _prewetPumpData.PumpPressureData = new MECF.Framework.Common.CommonData.CommonLimitData();
- _prewetPumpData.PumpFlowData = new MECF.Framework.Common.CommonData.CommonLimitData();
- _periodicJob = new PeriodicJob(100, OnTimer, $"{Module}.OnTimer", true);
- }
- /// <summary>
- /// 初始化
- /// </summary>
- /// <returns></returns>
- public bool Initialize()
- {
- InitializeParameter();
- InitializeRoutine();
- SubscribeData();
- SubscribeValueAction();
- InitializeOperation();
- return true;
- }
- /// <summary>
- /// 初始化参数
- /// </summary>
- private void InitializeParameter()
- {
- _prewetPersistentValue = PrewetPersistentManager.Instance.GetPrewetPersistentValue(Module);
- if (_prewetPersistentValue != null)
- {
- _lastPumpSpeed = _prewetPersistentValue.Speed;
- }
- else
- {
- LOG.WriteLog(eEvent.ERR_PREWET, Module, "Persistent Value Object is not exist");
- }
- }
- /// <summary>
- /// 初始化Routine
- /// </summary>
- private void InitializeRoutine()
- {
- _prewetPumpEnableRoutine = new PrewetPumpEnableRoutine(Module, this, _prewetPersistentValue);
- _prewetPumpDisableRoutine = new PrewetPumpDisableRoutine(Module, this, _prewetPersistentValue);
- }
- /// <summary>
- /// 订阅数据
- /// </summary>
- private void SubscribeData()
- {
- DATA.Subscribe($"{Module}.{PERSISTENT_VALUE}", () => _prewetPersistentValue, SubscriptionAttribute.FLAG.IgnoreSaveDB);
- DATA.Subscribe($"{Module}.{PUMP_DATA}", () => PrewetPumpData, SubscriptionAttribute.FLAG.IgnoreSaveDB);
- DATA.Subscribe($"{Module}.OfTotalTime", () => _runRecipeTotalTime ,SubscriptionAttribute.FLAG.IgnoreSaveDB);
- DATA.Subscribe($"{Module}.PumpStatus", () => PrewetPumpData.PumpStatus, SubscriptionAttribute.FLAG.IgnoreSaveDB);
- DATA.Subscribe($"{Module}.PumpCurrent",()=>PrewetPumpData.PumpCurrent,SubscriptionAttribute.FLAG.IgnoreSaveDB);
- DATA.Subscribe($"{Module}.PumpSpeed", () => _lastPumpSpeed, SubscriptionAttribute.FLAG.IgnoreSaveDB);
- DATA.Subscribe($"{Module}.PumpEnable", () => PrewetPumpData.PumpEnable, SubscriptionAttribute.FLAG.IgnoreSaveDB);
- DATA.Subscribe($"{Module}.PumpValve", () => PrewetPumpData.PumpValve, SubscriptionAttribute.FLAG.IgnoreSaveDB);
- DATA.Subscribe($"{Module}.PumpFlow", () => PrewetPumpData.PumpFlowData.Value, SubscriptionAttribute.FLAG.IgnoreSaveDB);
- DATA.Subscribe($"{Module}.PumpFlow.MinWarning", () => PrewetPumpData.PumpFlowData.MinWarning, SubscriptionAttribute.FLAG.IgnoreSaveDB);
- DATA.Subscribe($"{Module}.PumpFlow.MaxWarning", () => PrewetPumpData.PumpFlowData.MaxWarning, SubscriptionAttribute.FLAG.IgnoreSaveDB);
- DATA.Subscribe($"{Module}.PumpFlow.MinError", () => PrewetPumpData.PumpFlowData.MinError, SubscriptionAttribute.FLAG.IgnoreSaveDB);
- DATA.Subscribe($"{Module}.PumpFlow.MaxError", () => PrewetPumpData.PumpFlowData.MaxError, SubscriptionAttribute.FLAG.IgnoreSaveDB);
- DATA.Subscribe($"{Module}.PumpPressure", () => PrewetPumpData.PumpPressureData.Value, SubscriptionAttribute.FLAG.IgnoreSaveDB);
- DATA.Subscribe($"{Module}.PumpPressure.MinWarning", () => PrewetPumpData.PumpPressureData.MinWarning, SubscriptionAttribute.FLAG.IgnoreSaveDB);
- DATA.Subscribe($"{Module}.PumpPressure.MaxWarning", () => PrewetPumpData.PumpPressureData.MaxWarning, SubscriptionAttribute.FLAG.IgnoreSaveDB);
- DATA.Subscribe($"{Module}.PumpPressure.MinError", () => PrewetPumpData.PumpPressureData.MinError, SubscriptionAttribute.FLAG.IgnoreSaveDB);
- DATA.Subscribe($"{Module}.PumpPressure.MaxError", () => PrewetPumpData.PumpPressureData.MaxError, SubscriptionAttribute.FLAG.IgnoreSaveDB);
- DATA.Subscribe($"{Module}.TargetPressure", () => PrewetPumpData.PressureTarget, SubscriptionAttribute.FLAG.IgnoreSaveDB);
- }
- /// <summary>
- /// 订阅变量数值发生变化
- /// </summary>
- private void SubscribeValueAction()
- {
- BeckhoffIoSubscribeUpdateVariable( PUMP_VALVE);
- BeckhoffIoSubscribeUpdateVariable( PUMP_ENABLE);
- BeckhoffIoSubscribeUpdateVariable( PUMP_STAUS);
- BeckhoffIoSubscribeUpdateVariable( PUMP_CURRENT);
- BeckhoffIoSubscribeUpdateVariable( PUMP_PRESSURE);
- BeckhoffIoSubscribeUpdateVariable( PUMP_FLOW);
- }
- /// <summary>
- /// 订阅IO变量
- /// </summary>
- /// <param name="variable"></param>
- private void BeckhoffIoSubscribeUpdateVariable(string variable)
- {
- _variableInitializeDic[variable] = false;
- IOModuleManager.Instance.SubscribeModuleVariable(Module, variable, UpdateVariableValue);
- }
- /// <summary>
- /// 更新变量数值
- /// </summary>
- /// <param name="variable"></param>
- /// <param name="value"></param>
- private void UpdateVariableValue(string variable, object value)
- {
- if (!PrewetPumpData.IsDataInitialized)
- {
- PrewetPumpData.IsDataInitialized = true;
- PrewetPumpData.PumpModel = "Manual";
- }
- PropertyInfo property = PrewetPumpData.GetType().GetProperty(variable);
- if (property != null)
- {
- property.SetValue(PrewetPumpData, value);
- }
- if (_variableInitializeDic.ContainsKey(variable) && !_variableInitializeDic[variable])
- {
- _variableInitializeDic[variable] = true;
- }
- switch (variable)
- {
- case PUMP_STAUS:
- string statusContent = PrewetPumpData.PumpStatus ? "On" : "Off";
- PrewetPumpData.PumpStatusContent = $"{PrewetPumpData.PumpModel}: {statusContent}";
- break;
- case PUMP_FLOW:
- if (double.TryParse(value.ToString(), out var flow))
- {
- PrewetPumpData.PumpFlowData.Value = flow;
- }
- break;
- case PUMP_PRESSURE:
- if(double.TryParse(value.ToString(),out var pressure))
- {
- PrewetPumpData.PumpPressureData.Value = pressure;
- }
- break;
- }
- }
- /// <summary>
- /// 是否所有IO变量初始化完成
- /// </summary>
- /// <returns></returns>
- private bool AllIoVariableInitialized()
- {
- foreach (string item in _variableInitializeDic.Keys)
- {
- if (!_variableInitializeDic[item])
- {
- LOG.WriteLog(eEvent.ERR_PREWET, Module, $"{item} is not initialized");
- return false;
- }
- }
- return true;
- }
- /// <summary>
- /// 初始化操作
- /// </summary>
- private void InitializeOperation()
- {
- OP.Subscribe($"{Module}.PumpValveOn", PumpValveOnOperation);
- OP.Subscribe($"{Module}.PumpValveOff", PumpValveOffOperation);
- OP.Subscribe($"{Module}.PumpEnable", PumpEnableOperation);
- OP.Subscribe($"{Module}.PumpDisable", PumpDisableOperation);
- OP.Subscribe($"{Module}.PumpSpeedManual", PumpSpeedManualOperation);
- OP.Subscribe($"{Module}.PumpSpeedAuto", PumpSpeedAutoOperation);
- OP.Subscribe($"{Module}.PumpSpeedKeyDown", PumpSpeedKeyDownOperation);
- OP.Subscribe($"{Module}.DisabledAction", DisabledOperation);
- OP.Subscribe($"{Module}.ManualAction", ManualOperation);
- OP.Subscribe($"{Module}.AutoAction", AutoOperation);
- OP.Subscribe($"{Module}.EngineeringModeAction", EngineeringModeOperation);
- OP.Subscribe($"{Module}.ProductionModeAction", ProductionModeOperation);
- }
- /// <summary>
- /// 定时器
- /// </summary>
- /// <returns></returns>
- private bool OnTimer()
- {
- PrewetPumpData.PumpFlowData.MinError = SC.GetValue<double>($"Prewet.PumpFlow.Error_Min");
- PrewetPumpData.PumpFlowData.MinWarning = SC.GetValue<double>($"Prewet.PumpFlow.Warning_Min");
- PrewetPumpData.PumpFlowData.MaxError = SC.GetValue<double>($"Prewet.PumpFlow.Error_Max");
- PrewetPumpData.PumpFlowData.MaxWarning = SC.GetValue<double>($"Prewet.PumpFlow.Warning_Max");
- PrewetPumpData.PumpPressureData.MinError = SC.GetValue<double>($"Prewet.PumpPressure.Error_Min");
- PrewetPumpData.PumpPressureData.MinWarning = SC.GetValue<double>($"Prewet.PumpPressure.Warning_Min");
- PrewetPumpData.PumpPressureData.MaxError = SC.GetValue<double>($"Prewet.PumpPressure.Error_Max");
- PrewetPumpData.PumpPressureData.MaxWarning = SC.GetValue<double>($"Prewet.PumpPressure.Warning_Max");
- PrewetPumpData.PressureTarget = SC.GetValue<double>($"Prewet.PressureTarget");
- if (_status == RState.Running)
- {
- IRoutine routine = GetCurrentRoutine();
- if (routine != null)
- {
- RState rsState = routine.Monitor();
- if (rsState == RState.Failed || rsState == RState.Timeout)
- {
- _status = RState.Failed;
- _currentOperation = PrewetOperation.None;
- LOG.WriteLog(eEvent.ERR_LINMOT, Module.ToString(), $"{_currentOperation} error");
- IsStartAutoSpeed = false;
- }
- else if (rsState == RState.End)
- {
- if (_currentOperation == PrewetOperation.PumpEnable)
- {
- IsStartAutoSpeed = true;
- }
- else
- {
- IsStartAutoSpeed = false;
- }
- _status = RState.End;
- _currentOperation = PrewetOperation.None;
- }
- }
- }
- if (IsStartAutoSpeed)
- {
- AdjustPumpSpeed();
- }
- return true;
- }
- /// <summary>
- /// 调速
- /// </summary>
- public void AdjustPumpSpeed()
- {
- //Speed Auto模式同时pump enbled,根据kdi调整泵速
- if (PrewetPumpData.PumpSpeedAuto && PrewetPumpData.PumpEnable)
- {
- _pumpKp = SC.GetValue<double>($"Prewet.PumpKp");
- _pumpKd = SC.GetValue<double>($"Prewet.PumpKd");
- _pumpKi = SC.GetValue<double>($"Prewet.PumpKi");
- double limit = SC.GetValue<double>("Prewet.PrewetTargetLimit");
- short speed = PdiAlgorithm.Instance.CalculateSpeed(_pumpKp, _pumpKi, _pumpKd, PrewetPumpData.PressureTarget,
- PrewetPumpData.PumpPressureData.Value, _lastPumpSpeed,limit);
- if (Math.Abs(speed - _lastPumpSpeed) >= 1)
- {
- _lastPumpSpeed = speed;
- PumpSpeed(speed);
- }
- }
- else
- {
- IsStartAutoSpeed = false;
- }
- }
- /// <summary>
- /// 当前Routine;
- /// </summary>
- /// <returns></returns>
- private IRoutine GetCurrentRoutine()
- {
- switch (_currentOperation)
- {
- case PrewetOperation.PumpEnable:
- return _prewetPumpEnableRoutine;
- case PrewetOperation.PumpDisable:
- return _prewetPumpDisableRoutine;
- default:
- return null;
- }
- }
- #region Operation
- /// <summary>
- /// DisabledAction
- /// </summary>
- /// <param name="cmd"></param>
- /// <param name="param"></param>
- /// <returns></returns>
- private bool DisabledOperation(string cmd, object[] args)
- {
- string currentOperation = "Disabled";
- PrewetEntity prewetEntity = Singleton<RouteManager>.Instance.GetModule<PrewetEntity>(Module);
- if (prewetEntity == null || _prewetPersistentValue == null) return false;
- if (_prewetPersistentValue.OperatingMode != "Disabled") prewetEntity.EnterInit();
- _prewetPersistentValue.OperatingMode = currentOperation;
- PrewetPersistentManager.Instance.UpdatePersistentValue(Module);
- return true;
- }
- /// <summary>
- /// ManualAction
- /// </summary>
- /// <param name="cmd"></param>
- /// <param name="param"></param>
- /// <returns></returns>
- private bool ManualOperation(string cmd, object[] args)
- {
- string currentOperation = "Manual";
- PrewetEntity prewetEntity = Singleton<RouteManager>.Instance.GetModule<PrewetEntity>(Module);
- if (prewetEntity == null || _prewetPersistentValue == null) return false;
- if (_prewetPersistentValue.OperatingMode == "Auto" && prewetEntity.IsBusy)
- {
- LOG.WriteLog(eEvent.ERR_PREWET, Module, $"{Module} is Busy, can't change to manual mode");
- return false;
- }
- if (_prewetPersistentValue.OperatingMode != "Manual") prewetEntity.EnterInit();
- _prewetPersistentValue.OperatingMode = currentOperation;
- PrewetPersistentManager.Instance.UpdatePersistentValue(Module);
- return true;
- }
- /// <summary>
- /// AutoAction
- /// </summary>
- /// <param name="cmd"></param>
- /// <param name="param"></param>
- /// <returns></returns>
- private bool AutoOperation(string cmd, object[] args)
- {
- string currentOperation = "Auto";
- PrewetEntity prewetEntity = Singleton<RouteManager>.Instance.GetModule<PrewetEntity>(Module);
- if (prewetEntity == null || _prewetPersistentValue == null) return false;
- if (_prewetPersistentValue.OperatingMode != "Auto") prewetEntity.EnterInit();
- _prewetPersistentValue.OperatingMode = currentOperation;
- PrewetPersistentManager.Instance.UpdatePersistentValue(Module);
- return true;
- }
- /// <summary>
- /// EngineeringModeAction
- /// </summary>
- /// <param name="cmd"></param>
- /// <param name="param"></param>
- /// <returns></returns>
- private bool EngineeringModeOperation(string cmd, object[] args)
- {
- string currentRecipeOperation = "Engineering";
- _prewetPersistentValue.RecipeOperatingMode=currentRecipeOperation;
- PrewetPersistentManager.Instance.UpdatePersistentValue(Module);
- return true;
- }
- /// <summary>
- /// ProductionAction
- /// </summary>
- /// <param name="cmd"></param>
- /// <param name="param"></param>
- /// <returns></returns>
- private bool ProductionModeOperation(string cmd, object[] args)
- {
- string currentRecipeOperation = "Production";
- _prewetPersistentValue.RecipeOperatingMode = currentRecipeOperation;
- PrewetPersistentManager.Instance.UpdatePersistentValue(Module);
- return true;
- }
- /// <summary>
- /// Pump Valve On
- /// </summary>
- /// <param name="cmd"></param>
- /// <param name="param"></param>
- /// <returns></returns>
- public bool PumpValveOnOperation(string cmd, object[] param)
- {
- return PumpValveOpen();
- }
- /// <summary>
- /// Pump Valve Off
- /// </summary>
- /// <param name="cmd"></param>
- /// <param name="param"></param>
- /// <returns></returns>
- public bool PumpValveOffOperation(string cmd, object[] param)
- {
- return PumpValveClose();
- }
- /// <summary>
- /// Pump Valve Open
- /// </summary>
- /// <returns></returns>
- public bool PumpValveOpen()
- {
- string ioName = BeckhoffModuleIOManager.Instance.GetIoNameByInnerModuleName($"{Module}.{PUMP_VALVE}");
- return IOModuleManager.Instance.WriteIoValue(ioName, true);
- }
- /// <summary>
- /// Pump Valve Close
- /// </summary>
- /// <returns></returns>
- public bool PumpValveClose()
- {
- string ioName = BeckhoffModuleIOManager.Instance.GetIoNameByInnerModuleName($"{Module}.{PUMP_VALVE}");
- bool result= IOModuleManager.Instance.WriteIoValue(ioName, false);
- if(result && PrewetPumpData.PumpEnable)
- {
- PumpDisable();
- }
- return result;
- }
- /// <summary>
- /// Pump Enable操作
- /// </summary>
- /// <param name="cmd"></param>
- /// <param name="param"></param>
- /// <returns></returns>
- public bool PumpEnableOperation(string cmd, object[] param)
- {
- if (_status == RState.Running)
- {
- LOG.WriteLog(eEvent.ERR_PREWET, Module.ToString(), $"{Module} current execute {_currentOperation},cannot Pump enable");
- return false;
- }
- _status = _prewetPumpEnableRoutine.Start();
- _currentOperation = PrewetOperation.PumpEnable;
- return _status==RState.Running;
- }
- /// <summary>
- /// pump disable 操作
- /// </summary>
- /// <param name="cmd"></param>
- /// <param name="param"></param>
- /// <returns></returns>
- public bool PumpDisableOperation(string cmd, object[] param)
- {
- if (_status == RState.Running)
- {
- LOG.WriteLog(eEvent.ERR_PREWET, Module.ToString(), $"{Module} current execute {_currentOperation},cannot Pump disable");
- return false;
- }
- _status = _prewetPumpDisableRoutine.Start();
- _currentOperation = PrewetOperation.PumpDisable;
- return _status == RState.Running;
- //return PumpDisable();
- }
- /// <summary>
- /// Pump enable
- /// </summary>
- /// <returns></returns>
- public bool PumpEnable()
- {
- string ioName = BeckhoffModuleIOManager.Instance.GetIoNameByInnerModuleName($"{Module}.{PUMP_ENABLE}");
- return IOModuleManager.Instance.WriteIoValue(ioName, true);
- }
- /// <summary>
- /// Pump disable
- /// </summary>
- /// <returns></returns>
- public bool PumpDisable()
- {
- string ioName = BeckhoffModuleIOManager.Instance.GetIoNameByInnerModuleName($"{Module}.{PUMP_ENABLE}");
- return IOModuleManager.Instance.WriteIoValue(ioName, false);
- }
- /// <summary>
- /// 写入Pump速度
- /// </summary>
- /// <param name="speed"></param>
- /// <returns></returns>
- public bool PumpSpeed(short speed=0)
- {
- string ioName = BeckhoffModuleIOManager.Instance.GetIoNameByInnerModuleName($"{Module}.{PUMP_SPEED}");
- return IOModuleManager.Instance.WriteIoValue(ioName, speed==0?_lastPumpSpeed:speed);
- }
- /// <summary>
- /// Pump Speed手动模式
- /// </summary>
- /// <param name="cmd"></param>
- /// <param name="param"></param>
- /// <returns></returns>
- public bool PumpSpeedManualOperation(string cmd, object[] param)
- {
- PrewetPumpData.PumpSpeedAuto = false;
- PrewetPumpData.PumpModel = "Manual";
- string statusContent = PrewetPumpData.PumpStatus ? "On" : "Off";
- PrewetPumpData.PumpStatusContent = $"{PrewetPumpData.PumpModel}: {statusContent}";
- return true;
- }
- /// <summary>
- /// Pump Speed自动模式
- /// </summary>
- /// <param name="cmd"></param>
- /// <param name="param"></param>
- /// <returns></returns>
- public bool PumpSpeedAutoOperation(string cmd, object[] param)
- {
- PrewetPumpData.PumpSpeedAuto = true;
- PrewetPumpData.PumpModel = "Auto";
- string statusContent = PrewetPumpData.PumpStatus ? "On" : "Off";
- PrewetPumpData.PumpStatusContent = $"{PrewetPumpData.PumpModel}: {statusContent}";
- return true;
- }
- /// <summary>
- /// Pump Speed回车操作
- /// </summary>
- /// <param name="cmd"></param>
- /// <param name="param"></param>
- /// <returns></returns>
- public bool PumpSpeedKeyDownOperation(string cmd, object[] param)
- {
- if (PrewetPumpData.PumpSpeedAuto)
- {
- LOG.WriteLog(eEvent.ERR_PREWET, Module, "Pump speed is auto,cannot change speed");
- return false;
- }
- short speed=(short)param[0];
- bool result = PumpSpeed(speed);
- if(result)
- {
- _prewetPersistentValue.Speed = speed;
- _lastPumpSpeed = speed;
- PrewetPersistentManager.Instance.UpdatePersistentValue(Module);
- }
- return true;
- }
- /// <summary>
- /// 中止当前Routine
- /// </summary>
- public void AbortCurrentRoutine()
- {
- if (_status == RState.Running)
- {
- IRoutine routine = GetCurrentRoutine();
- if (routine != null)
- {
- routine.Abort();
- _currentOperation = PrewetOperation.None;
- }
- }
- }
- #endregion
- #region 设备接口
- /// <summary>
- /// 监控
- /// </summary>
- public void Monitor()
- {
- }
- public void Reset()
- {
- }
- public void Terminate()
- {
- _prewetPersistentValue.Speed = _lastPumpSpeed;
- PrewetPersistentManager.Instance.UpdatePersistentValue(Module);
- _periodicJob.Stop(false);
- }
- #endregion
- }
- }
|