| 123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182183184185186187188189190191192193194195196197198199200201202203204205206207208209210211212213214215216217218219220221222223224225226227228229230231232233234235236237238239240241242243244245246247248249250251252253254255256257258259260261262263264265266267268269270271272273274275276277278 | using Aitex.Core.RT.Device;using Aitex.Core.RT.Log;using Aitex.Core.RT.Routine;using Aitex.Core.RT.SCCore;using MECF.Framework.Common.Beckhoff.ModuleIO;using MECF.Framework.Common.Routine;using MECF.Framework.Common.ToolLayout;using MECF.Framework.Common.TwinCat;using CyberX8_Core;using CyberX8_RT.Devices.Metal;using CyberX8_RT.Devices.Reservoir;using System;using System.Collections.Generic;using System.Linq;using System.Text;using System.Threading.Tasks;using CyberX8_RT.Devices.Safety;using MECF.Framework.Common.IOCore;namespace CyberX8_RT.Modules.Reservoir{    public class ANPumpOnRoutine : RoutineBase, IRoutine    {        private enum ANPumpStep        {            PumpSpeed,            Delay,            ANByPass,            CellsFillValve,            FlowDelay,            CheckFlow,            CheckByPass,            End        }        #region 常量        private const string AN_A_PINENABLE = "ANAPinEnable";        private const string AN_B_PINENABLE = "ANBPinEnable";        private const string AN_PUMP = "ANPump";        private const string AN_BY_PASS = "ANByPass";        #endregion        #region 内部变量        /// <summary>        /// 默认泵速        /// </summary>        private double _anPumpSpeed = 5000;        /// <summary>        /// flow fault hold off时长        /// </summary>        private int _flowFaultHoldOffTime = 10000;        /// <summary>        /// 阳极最小流量         /// </summary>        private double _anMinFlow = 0.2;        /// <summary>        /// 最小Bypass数值        /// </summary>        private int _anBypassMinCellCount;        /// <summary>        /// AN流量总和        /// </summary>        private double _anTotalFlow = 0;        /// <summary>        /// Reservoir设备        /// </summary>        private CompactMembranReservoirDevice _device;        /// <summary>        /// 阳极打开阀Cell总数        /// </summary>        private int _anOpenValveCount;        #endregion        /// <summary>        /// 构造函数        /// </summary>        /// <param name="module"></param>        public ANPumpOnRoutine(string module) : base(module)        {        }        /// <summary>        /// 中止        /// </summary>        public void Abort()        {            Runner.Stop("Manual abort");        }        /// <summary>        /// 监控        /// </summary>        /// <returns></returns>        public RState Monitor()        {            Runner.Run(ANPumpStep.PumpSpeed, () => { return ANPumpSpeed(_anPumpSpeed); }, _delay_1ms)                .Run(ANPumpStep.ANByPass,ANByPassOn,_delay_1ms)                .Run(ANPumpStep.CellsFillValve, OpenAllCellsFillValve,_delay_1ms)                .Delay(ANPumpStep.Delay, _flowFaultHoldOffTime)                .Run(ANPumpStep.CheckFlow,CheckAllFlow,_delay_1ms)                .RunIf(ANPumpStep.CheckByPass, CheckTotalFlowBypass(),ANByPassOff,NullFun,_delay_1ms)                .End(ANPumpStep.End, NullFun, _delay_1ms);            return Runner.Status;        }        /// <summary>        /// Pump Speed        /// </summary>        /// <param name="speed"></param>        /// <returns></returns>        private bool ANPumpSpeed(double speed)        {            SafetyDevice safetyDevice = DEVICE.GetDevice<SafetyDevice>("Safety");            if (safetyDevice != null && !safetyDevice.SafetyData.PumpEdm)            {                LOG.WriteLog(eEvent.ERR_RESERVOIR, Module, $"Safety PumpEdm is Activate");                return false;            }            string ioName = BeckhoffModuleIOManager.Instance.GetIoNameByInnerModuleName($"{Module}.{AN_PUMP}");            return IOModuleManager.Instance.WriteIoValue(ioName, speed);        }        /// <summary>        /// Pump Bypass        /// </summary>        /// <param name="speed"></param>        /// <returns></returns>        private bool ANByPassOn()        {            string ioName = BeckhoffModuleIOManager.Instance.GetIoNameByInnerModuleName($"{Module}.{AN_BY_PASS}");            return IOModuleManager.Instance.WriteIoValue(ioName, true);        }        /// <summary>        /// Pump Bypass        /// </summary>        /// <param name="speed"></param>        /// <returns></returns>        private bool ANByPassOff()        {            string ioName = BeckhoffModuleIOManager.Instance.GetIoNameByInnerModuleName($"{Module}.{AN_BY_PASS}");            return IOModuleManager.Instance.WriteIoValue(ioName, false);        }        /// <summary>        /// 检验所有流量        /// </summary>        /// <returns></returns>        private bool OpenAllCellsFillValve()        {            bool result = false;            ReservoirItem reservoirItem = ReservoirItemManager.Instance.GetReservoirItem(Module.ToString());            if (reservoirItem != null)            {                List<MetalItem> metalItems = reservoirItem.MetalCells;                if (metalItems != null && metalItems.Count > 0)                {                    foreach (MetalItem metalItem in metalItems)                    {                        if (metalItem.Installed)                        {                            CompactMembranMetalDevice metalDevice = DEVICE.GetDevice<CompactMembranMetalDevice>(metalItem.ModuleName);                            if (metalDevice != null && metalDevice.IsAuto)                            {                                _anOpenValveCount++;                                result = metalDevice.AnSideAFillOn("", null);                                if(!result)                                {                                    return false;                                }                                result = metalDevice.AnSideBFillOn("", null);                                if (!result)                                {                                    return false;                                }                            }                        }                    }                }            }            return true;        }        /// <summary>        /// 关闭所有Cell的Flow Valve        /// </summary>        /// <returns></returns>        private bool CloseAllCellsFlowValve()        {            ReservoirItem reservoirItem = ReservoirItemManager.Instance.GetReservoirItem(Module.ToString());            if (reservoirItem != null)            {                List<MetalItem> metalItems = reservoirItem.MetalCells;                if (metalItems != null && metalItems.Count > 0)                {                    foreach (MetalItem metalItem in metalItems)                    {                        if (metalItem.Installed)                        {                            CompactMembranMetalDevice metalDevice = DEVICE.GetDevice<CompactMembranMetalDevice>(metalItem.ModuleName);                            if (metalDevice != null && metalDevice.IsAuto)                            {                                metalDevice.AnSideAFillOff("", null);                                metalDevice.AnSideBFillOff("", null);                            }                        }                    }                }            }            return true;        }        /// <summary>        /// 检验所有流量        /// </summary>        /// <returns></returns>        private bool CheckAllFlow()        {            if (_anOpenValveCount == 0)            {                return true;            }            _anTotalFlow = 0.0;            ReservoirItem reservoirItem = ReservoirItemManager.Instance.GetReservoirItem(Module.ToString());            if (reservoirItem != null)            {                List<MetalItem> metalItems = reservoirItem.MetalCells;                if (metalItems != null && metalItems.Count > 0)                {                    foreach (MetalItem metalItem in metalItems)                    {                        if (metalItem.Installed)                        {                            CompactMembranMetalDevice metalDevice = DEVICE.GetDevice<CompactMembranMetalDevice>(metalItem.ModuleName);                            if (metalDevice != null&&metalDevice.IsAuto)                            {                                _anTotalFlow += metalDevice.ANACellFlow.CounterValue;                                _anTotalFlow += metalDevice.ANBCellFlow.CounterValue;                            }                        }                    }                }            }            if(_anTotalFlow<=_anMinFlow)            {                CloseAllCellsFlowValve();                ANPumpSpeed(0);                LOG.WriteLog(eEvent.ERR_RESERVOIR, Module, $"total flow {_anTotalFlow} is not over {_anMinFlow}");                return false;            }            else            {                LOG.WriteLog(eEvent.INFO_RESERVOIR, Module, $"total flow {_anTotalFlow} is over {_anMinFlow}");                return true;            }        }        /// <summary>        /// 检验总流量Bypass情况        /// </summary>        /// <returns></returns>        private bool CheckTotalFlowBypass()        {            return _anTotalFlow > _anBypassMinCellCount;        }        /// <summary>        /// 启动        /// </summary>        /// <param name="objs"></param>        /// <returns></returns>        public RState Start(params object[] objs)        {            _device = DEVICE.GetDevice<CompactMembranReservoirDevice>(Module);            _anPumpSpeed = SC.GetValue<double>("Reservoir.ANDefaultPumpSpeed");            _flowFaultHoldOffTime = SC.GetValue<int>($"Reservoir.{Module}.FlowFaultHoldOffTime");            _anBypassMinCellCount = SC.GetValue<int>($"Reservoir.{Module}.ANBypassMinCellCount");            _anTotalFlow = 0;            return Runner.Start(Module, "AN Pump On");        }    }}
 |