1234567891011121314151617181920212223242526272829303132333435363738394041424344454647484950515253545556575859606162636465666768697071727374757677787980818283848586878889909192939495969798991001011021031041051061071081091101111121131141151161171181191201211221231241251261271281291301311321331341351361371381391401411421431441451461471481491501511521531541551561571581591601611621631641651661671681691701711721731741751761771781791801811821831841851861871881891901911921931941951961971981992002012022032042052062072082092102112122132142152162172182192202212222232242252262272282292302312322332342352362372382392402412422432442452462472482492502512522532542552562572582592602612622632642652662672682692702712722732742752762772782792802812822832842852862872882892902912922932942952962972982993003013023033043053063073083093103113123133143153163173183193203213223233243253263273283293303313323333343353363373383393403413423433443453463473483493503513523533543553563573583593603613623633643653663673683693703713723733743753763773783793803813823833843853863873883893903913923933943953963973983994004014024034044054064074084094104114124134144154164174184194204214224234244254264274284294304314324334344354364374384394404414424434444454464474484494504514524534544554564574584594604614624634644654664674684694704714724734744754764774784794804814824834844854864874884894904914924934944954964974984995005015025035045055065075085095105115125135145155165175185195205215225235245255265275285295305315325335345355365375385395405415425435445455465475485495505515525535545555565575585595605615625635645655665675685695705715725735745755765775785795805815825835845855865875885895905915925935945955965975985996006016026036046056066076086096106116126136146156166176186196206216226236246256266276286296306316326336346356366376386396406416426436446456466476486496506516526536546556566576586596606616626636646656666676686696706716726736746756766776786796806816826836846856866876886896906916926936946956966976986997007017027037047057067077087097107117127137147157167177187197207217227237247257267277287297307317327337347357367377387397407417427437447457467477487497507517527537547557567577587597607617627637647657667677687697707717727737747757767777787797807817827837847857867877887897907917927937947957967977987998008018028038048058068078088098108118128138148158168178188198208218228238248258268278288298308318328338348358368378388398408418428438448458468478488498508518528538548558568578588598608618628638648658668678688698708718728738748758768778788798808818828838848858868878888898908918928938948958968978988999009019029039049059069079089099109119129139149159169179189199209219229239249259269279289299309319329339349359369379389399409419429439449459469479489499509519529539549559569579589599609619629639649659669679689699709719729739749759769779789799809819829839849859869879889899909919929939949959969979989991000100110021003100410051006100710081009101010111012101310141015101610171018101910201021102210231024102510261027102810291030103110321033103410351036103710381039104010411042104310441045104610471048104910501051105210531054105510561057105810591060106110621063106410651066106710681069107010711072107310741075107610771078107910801081108210831084108510861087108810891090109110921093109410951096109710981099110011011102110311041105110611071108110911101111111211131114111511161117111811191120112111221123112411251126112711281129113011311132113311341135113611371138113911401141114211431144114511461147114811491150115111521153115411551156115711581159116011611162116311641165116611671168116911701171117211731174117511761177117811791180118111821183118411851186118711881189119011911192119311941195119611971198119912001201120212031204120512061207120812091210121112121213121412151216121712181219122012211222122312241225122612271228122912301231123212331234123512361237123812391240124112421243124412451246124712481249125012511252125312541255125612571258125912601261126212631264126512661267126812691270127112721273127412751276127712781279128012811282128312841285128612871288128912901291129212931294129512961297129812991300130113021303130413051306130713081309131013111312131313141315131613171318131913201321132213231324132513261327132813291330133113321333133413351336133713381339134013411342134313441345134613471348134913501351135213531354135513561357135813591360136113621363136413651366136713681369137013711372137313741375137613771378137913801381138213831384138513861387138813891390139113921393139413951396139713981399140014011402140314041405140614071408140914101411141214131414141514161417141814191420142114221423142414251426142714281429143014311432143314341435143614371438143914401441144214431444144514461447144814491450145114521453145414551456145714581459146014611462146314641465146614671468146914701471147214731474147514761477147814791480148114821483148414851486148714881489149014911492149314941495149614971498149915001501150215031504150515061507150815091510151115121513151415151516151715181519152015211522152315241525152615271528152915301531153215331534153515361537153815391540154115421543154415451546154715481549155015511552155315541555155615571558155915601561156215631564156515661567156815691570157115721573157415751576157715781579158015811582158315841585158615871588158915901591159215931594159515961597159815991600160116021603160416051606160716081609161016111612161316141615161616171618161916201621162216231624162516261627162816291630163116321633163416351636163716381639164016411642164316441645164616471648164916501651165216531654165516561657165816591660166116621663166416651666166716681669167016711672167316741675167616771678167916801681168216831684168516861687168816891690169116921693169416951696169716981699170017011702170317041705170617071708170917101711171217131714171517161717171817191720172117221723172417251726172717281729173017311732173317341735173617371738173917401741174217431744174517461747174817491750175117521753175417551756175717581759176017611762176317641765176617671768176917701771177217731774177517761777177817791780178117821783178417851786178717881789179017911792179317941795179617971798179918001801180218031804180518061807180818091810181118121813181418151816181718181819182018211822182318241825182618271828182918301831183218331834183518361837183818391840184118421843184418451846184718481849185018511852185318541855185618571858185918601861186218631864186518661867186818691870187118721873187418751876187718781879188018811882188318841885188618871888188918901891189218931894189518961897189818991900190119021903190419051906190719081909191019111912191319141915191619171918191919201921192219231924192519261927192819291930193119321933193419351936193719381939194019411942194319441945194619471948194919501951195219531954195519561957195819591960196119621963196419651966196719681969197019711972197319741975197619771978197919801981198219831984198519861987198819891990199119921993199419951996199719981999200020012002200320042005200620072008200920102011201220132014201520162017201820192020202120222023202420252026202720282029203020312032203320342035203620372038203920402041204220432044204520462047204820492050205120522053205420552056205720582059206020612062206320642065206620672068206920702071207220732074207520762077207820792080208120822083208420852086208720882089209020912092209320942095209620972098209921002101210221032104210521062107210821092110211121122113211421152116211721182119212021212122212321242125212621272128212921302131213221332134213521362137213821392140214121422143214421452146214721482149215021512152215321542155215621572158215921602161216221632164216521662167216821692170217121722173217421752176217721782179218021812182218321842185218621872188218921902191219221932194219521962197219821992200220122022203220422052206220722082209221022112212221322142215221622172218221922202221222222232224222522262227222822292230223122322233223422352236223722382239224022412242224322442245224622472248224922502251225222532254225522562257225822592260226122622263226422652266226722682269227022712272227322742275227622772278227922802281228222832284228522862287228822892290229122922293229422952296229722982299230023012302230323042305230623072308230923102311231223132314231523162317231823192320232123222323232423252326232723282329233023312332233323342335233623372338233923402341234223432344234523462347234823492350235123522353235423552356235723582359236023612362236323642365236623672368236923702371237223732374237523762377237823792380238123822383238423852386238723882389239023912392239323942395239623972398239924002401240224032404240524062407240824092410241124122413241424152416241724182419242024212422242324242425242624272428242924302431243224332434243524362437243824392440244124422443244424452446244724482449245024512452245324542455245624572458245924602461246224632464246524662467246824692470247124722473247424752476247724782479248024812482248324842485248624872488248924902491249224932494249524962497249824992500250125022503250425052506250725082509251025112512251325142515251625172518251925202521252225232524252525262527252825292530253125322533253425352536253725382539254025412542254325442545254625472548254925502551255225532554255525562557255825592560256125622563256425652566256725682569257025712572257325742575257625772578257925802581258225832584258525862587258825892590259125922593259425952596259725982599260026012602260326042605260626072608260926102611261226132614261526162617261826192620262126222623262426252626262726282629263026312632263326342635263626372638263926402641264226432644264526462647264826492650265126522653265426552656265726582659266026612662266326642665266626672668266926702671267226732674267526762677267826792680268126822683268426852686268726882689269026912692269326942695269626972698269927002701270227032704270527062707270827092710271127122713271427152716271727182719272027212722272327242725272627272728272927302731273227332734273527362737273827392740274127422743274427452746274727482749275027512752275327542755275627572758275927602761276227632764276527662767276827692770277127722773277427752776277727782779278027812782278327842785278627872788278927902791279227932794279527962797279827992800280128022803280428052806280728082809281028112812281328142815281628172818281928202821282228232824282528262827282828292830283128322833283428352836283728382839284028412842284328442845284628472848284928502851285228532854285528562857285828592860286128622863286428652866286728682869287028712872287328742875287628772878287928802881288228832884288528862887288828892890289128922893289428952896289728982899290029012902290329042905290629072908290929102911291229132914291529162917
  1. <?xml version="1.0"?>
  2. <TcEventSources Version="2">
  3. <Source>
  4. <GUID>{28111931-0002-0000-5230-7E0700001100}</GUID>
  5. <Name LcId="1031">EL1918, 8K. Safety Eingang 24V, TwinSAFE</Name>
  6. <Name LcId="1033">EL1918, 8Ch. Safety Input 24V, TwinSAFE</Name>
  7. <Event>
  8. <Id>1</Id>
  9. <Message LcId="1033">Primary MC: GLOBAL_Fault with Code 0x{0,x} and Additional Code 0x{1,x}</Message>
  10. </Event>
  11. <Event>
  12. <Id>2</Id>
  13. <Message LcId="1033">Primary MC: GLOBAL_Shutdown with Code 0x{0,x} and Additional Code 0x{1,x}</Message>
  14. </Event>
  15. <Event>
  16. <Id>3</Id>
  17. <Message LcId="1033">Secondary MC: GLOBAL_Fault with Code 0x{0,x} and Additional Code 0x{1,x}</Message>
  18. </Event>
  19. <Event>
  20. <Id>4</Id>
  21. <Message LcId="1033">Secondary MC: GLOBAL_Shutdown with Code 0x{0,x} and Additional Code 0x{1,x}</Message>
  22. </Event>
  23. <Event>
  24. <Id>5</Id>
  25. <Message LcId="1033">Primary MC: Stored GLOBAL_Fault with Code 0x{0,x} and Additional Code 0x{1,x}</Message>
  26. </Event>
  27. <Event>
  28. <Id>6</Id>
  29. <Message LcId="1033">Secondary MC: Stored GLOBAL_Fault with Code 0x{0,x} and Additional Code 0x{1,x}</Message>
  30. </Event>
  31. <Event>
  32. <Id>7</Id>
  33. <Message LcId="1033">Diag-Message-Overflow: {0} messages got lost</Message>
  34. </Event>
  35. <Event>
  36. <Id>8</Id>
  37. <Message LcId="1033">Primary MC: the CRC of the FRAM Data was wrong (Diag-Code={0})</Message>
  38. </Event>
  39. <Event>
  40. <Id>9</Id>
  41. <Message LcId="1033">Secondary MC: the CRC of the FRAM Data was wrong (Diag-Code={0})</Message>
  42. </Event>
  43. <Event>
  44. <Id>16</Id>
  45. <Message LcId="1033">Reserved CfgData has to be zero st offset {0}</Message>
  46. </Event>
  47. <Event>
  48. <Id>17</Id>
  49. <Message LcId="1033">The password is wrong</Message>
  50. </Event>
  51. <Event>
  52. <Id>18</Id>
  53. <Message LcId="1033">The user was not found</Message>
  54. </Event>
  55. <Event>
  56. <Id>19</Id>
  57. <Message LcId="1033">The CRC of the login data does not match</Message>
  58. </Event>
  59. <Event>
  60. <Id>20</Id>
  61. <Message LcId="1033">The serial number of the login data does not match</Message>
  62. </Event>
  63. <Event>
  64. <Id>21</Id>
  65. <Message LcId="1033">The login watchdog has been expired</Message>
  66. </Event>
  67. <Event>
  68. <Id>22</Id>
  69. <Message LcId="1033">The user was logged out before</Message>
  70. </Event>
  71. <Event>
  72. <Id>23</Id>
  73. <Message LcId="1033">The user has not sufficient access rights</Message>
  74. </Event>
  75. <Event>
  76. <Id>24</Id>
  77. <Message LcId="1033">The reserved area of the CfgData was not 0</Message>
  78. </Event>
  79. <Event>
  80. <Id>25</Id>
  81. <Message LcId="1033">The CRC of the CfgData was wrong</Message>
  82. </Event>
  83. <Event>
  84. <Id>26</Id>
  85. <Message LcId="1033">The user name is wrong at word offset 0x{0,x} when changing the password</Message>
  86. </Event>
  87. <Event>
  88. <Id>27</Id>
  89. <Message LcId="1033">The requested number of users is too big</Message>
  90. </Event>
  91. <Event>
  92. <Id>29</Id>
  93. <Message LcId="1033">The user update flags are wrong at word offset 0x{0,x} when changing the password</Message>
  94. </Event>
  95. <Event>
  96. <Id>30</Id>
  97. <Message LcId="1033">The wrong user (user {0}) is logged in when changing the password (user {1} found in the received data)</Message>
  98. </Event>
  99. <Event>
  100. <Id>33</Id>
  101. <Message LcId="1033">the maximum Global-Shutdown counter was exceeded in the Vendor Data (maximum value: {0}, actual value: {1})</Message>
  102. </Event>
  103. <Event>
  104. <Id>48</Id>
  105. <Message LcId="1033">Sync Manager 2 Address (0x{0,x}) is invalid, minimum value = 0x{1,x}, maximum value = 0x{2,x}</Message>
  106. </Event>
  107. <Event>
  108. <Id>49</Id>
  109. <Message LcId="1033">Sync Manager 3 Address (0x{0,x}) is invalid, minimum value = 0x{1,x}, maximum value = 0x{2,x}</Message>
  110. </Event>
  111. <Event>
  112. <Id>50</Id>
  113. <Message LcId="1033">Sync Manager 4 Address (0x{0,x}) is invalid, minimum value = 0x{1,x}, maximum value = 0x{2,x}</Message>
  114. </Event>
  115. <Event>
  116. <Id>51</Id>
  117. <Message LcId="1033">Sync Manager 5 Address (0x{0,x}) is invalid, minimum value = 0x{1,x}, maximum value = 0x{2,x}</Message>
  118. </Event>
  119. <Event>
  120. <Id>52</Id>
  121. <Message LcId="1033">Sync Manager 2 Size ({0}) is invalid, minimum value = {1}, maximum value = {2}</Message>
  122. </Event>
  123. <Event>
  124. <Id>53</Id>
  125. <Message LcId="1033">Sync Manager 3 Size ({0}) is invalid, minimum value = {1}, maximum value = {2}</Message>
  126. </Event>
  127. <Event>
  128. <Id>54</Id>
  129. <Message LcId="1033">Sync Manager 4 Size ({0}) is invalid, minimum value = {1}, maximum value = {2}</Message>
  130. </Event>
  131. <Event>
  132. <Id>55</Id>
  133. <Message LcId="1033">Sync Manager 5 Size ({0}) is invalid, minimum value = {1}, maximum value = {2}</Message>
  134. </Event>
  135. <Event>
  136. <Id>56</Id>
  137. <Message LcId="1033">Sync Manager {0} Settings (Offset 4-7) are invalid, expected values = 0x{1,x}, 0x{2,x}</Message>
  138. </Event>
  139. <Event>
  140. <Id>68</Id>
  141. <Message LcId="1033">Sync Manager 6 Address (0x{0,x}) is invalid, minimum value = 0x{1,x}, maximum value = 0x{2,x}</Message>
  142. </Event>
  143. <Event>
  144. <Id>69</Id>
  145. <Message LcId="1033">Sync Manager 7 Address (0x{0,x}) is invalid, minimum value = 0x{1,x}, maximum value = 0x{2,x}</Message>
  146. </Event>
  147. <Event>
  148. <Id>72</Id>
  149. <Message LcId="1033">Sync Manager 6 Size ({0}) is invalid, minimum value = {1}, maximum value = {2}</Message>
  150. </Event>
  151. <Event>
  152. <Id>73</Id>
  153. <Message LcId="1033">Sync Manager 7 Size ({0}) is invalid, minimum value = {1}, maximum value = {2}</Message>
  154. </Event>
  155. <Event>
  156. <Id>257</Id>
  157. <Message LcId="1033">Primary MC: Completed RAM TEST: Starttime: 0x{0,x} and Stoptime: 0x{1,x} . The calculated timediff is 0x{2,x}.</Message>
  158. </Event>
  159. <Event>
  160. <Id>258</Id>
  161. <Message LcId="1033">Secondary MC: Completed RAM TEST: Starttime: 0x{0,x} and Stoptime: 0x{1,x} . The calculated timediff is 0x{2,x}.</Message>
  162. </Event>
  163. <Event>
  164. <Id>259</Id>
  165. <Message LcId="1033">C1 MCTEST Info: Arg1: 0x{0,x}, Arg2: 0x{1,x}, Arg3: 0x{2,x}.</Message>
  166. </Event>
  167. <Event>
  168. <Id>260</Id>
  169. <Message LcId="1033">C2 MCTEST Info: Arg1: 0x{0,x}, Arg2: 0x{1,x}, Arg3: 0x{2,x}.</Message>
  170. </Event>
  171. <Event>
  172. <Id>277</Id>
  173. <Message LcId="1033"><![CDATA[Controller {0}: Maximum temperature exceeded. Temperature is 0x{1,x}, should be <= 0x{2,x}.]]></Message>
  174. </Event>
  175. <Event>
  176. <Id>278</Id>
  177. <Message LcId="1033"><![CDATA[Controller {0}: Minimum temperature alert. Temperature is 0x{1,x}, should be >= 0x{2,x}.]]></Message>
  178. </Event>
  179. <Event>
  180. <Id>279</Id>
  181. <Message LcId="1033"><![CDATA[Controller {0}: Temperature difference too high. Difference is {1}, should be <= {2}.]]></Message>
  182. </Event>
  183. <Event>
  184. <Id>280</Id>
  185. <Message LcId="1033"><![CDATA[Controller {0}: Maximum voltage alert (Partner_VCC). Voltage is 0x{1,x}, should be <= 0x{2,x}.]]></Message>
  186. </Event>
  187. <Event>
  188. <Id>281</Id>
  189. <Message LcId="1033"><![CDATA[Controller {0}: Minimum voltage alert (Partner_VCC). Voltage is 0x{1,x}, should be >= 0x{2,x}.]]></Message>
  190. </Event>
  191. <Event>
  192. <Id>282</Id>
  193. <Message LcId="1033"><![CDATA[Controller {0}: Maximum voltage alert (ECAT_VCC). Voltage is 0x{1,x}, should be <= 0x{2,x}.]]></Message>
  194. </Event>
  195. <Event>
  196. <Id>283</Id>
  197. <Message LcId="1033"><![CDATA[Controller {0}: Minimum voltage alert (ECAT_VCC). Voltage is 0x{1,x}, should be >= 0x{2,x}.]]></Message>
  198. </Event>
  199. <Event>
  200. <Id>286</Id>
  201. <Message LcId="1033"><![CDATA[Controller {0}: Timer Tick Difference is too high. Difference is 0x{1,x}, should be >= 0x{2,x}.]]></Message>
  202. </Event>
  203. <Event>
  204. <Id>287</Id>
  205. <Message LcId="1033">Controller {0}: Minimum value alert (Individual ADC Check). Channel parameter = {1}. Actual value is 0x{2,x}.</Message>
  206. </Event>
  207. <Event>
  208. <Id>288</Id>
  209. <Message LcId="1033">Controller {0}: Maximum value alert (Individual ADC Check). Channel parameter = {1}. Actual value is 0x{2,x}.</Message>
  210. </Event>
  211. <Event>
  212. <Id>289</Id>
  213. <Message LcId="1033">Module Shutdown due to minimum value alert (Individual ADC Check). Channel parameter = {0}.</Message>
  214. </Event>
  215. <Event>
  216. <Id>4096</Id>
  217. <Message LcId="1033">The size of the safe User Parameter is too small ({0}), the expected size is {1}</Message>
  218. </Event>
  219. <Event>
  220. <Id>4097</Id>
  221. <Message LcId="1033">The Vendor-ID ({0}) is unequal the expected value of {1}</Message>
  222. </Event>
  223. <Event>
  224. <Id>4098</Id>
  225. <Message LcId="1033">The Product-Code ({0}) is unequal the expected value of {1}</Message>
  226. </Event>
  227. <Event>
  228. <Id>4099</Id>
  229. <Message LcId="1033">The reserved data of the SafeOut User Parameter of module {0} at byte offset 0x{1,x} has to be 0</Message>
  230. </Event>
  231. <Event>
  232. <Id>4100</Id>
  233. <Message LcId="1033">The reserved data of the SafeIn User Parameter of module {0} at byte offset 0x{1,x} has to be 0</Message>
  234. </Event>
  235. <Event>
  236. <Id>4101</Id>
  237. <Message LcId="1033">The standard outputs of module {0} should be enabled but the Sync-Manager 6 is not configured or enabled correctly</Message>
  238. </Event>
  239. <Event>
  240. <Id>4102</Id>
  241. <Message LcId="1033">The FASTSTDOUT mode of the standard outputs of module {0} is not supported</Message>
  242. </Event>
  243. <Event>
  244. <Id>4103</Id>
  245. <Message LcId="1033">The SAFEOUT-Module-Number ({0}) for the ExternalPulseDetection of the SAFEIN-Module {1} is wrong, the allowed range is 1-{2}</Message>
  246. </Event>
  247. <Event>
  248. <Id>4104</Id>
  249. <Message LcId="1033">The SAFEOUT-Channel-Number ({0}) for the ExternalPulseDetection of the SAFEIN-Module {1} is wrong, the allowed range is 1-{2}</Message>
  250. </Event>
  251. <Event>
  252. <Id>4105</Id>
  253. <Message LcId="1033">The Bumper-Mode {0} is not supported for SAFEIN-Module {1}</Message>
  254. </Event>
  255. <Event>
  256. <Id>4106</Id>
  257. <Message LcId="1033">The version of the Product-Code (0x{0,x}) is unequal the expected value of 0x{1,x}</Message>
  258. </Event>
  259. <Event>
  260. <Id>4112</Id>
  261. <Message LcId="1033">The default Project CRC is wrong, the received value is 0x{0,x}</Message>
  262. </Event>
  263. <Event>
  264. <Id>4128</Id>
  265. <Message LcId="1033">The watchdog for the Standard Outputs was expired</Message>
  266. </Event>
  267. <Event>
  268. <Id>4144</Id>
  269. <Message LcId="1033">The size of the safe User Parameter is too big ({0}), the expected size is {1}</Message>
  270. </Event>
  271. <Event>
  272. <Id>5569</Id>
  273. <Message LcId="1033">SAFEIN-Module {0}: Module Fault due to Fault Link</Message>
  274. </Event>
  275. <Event>
  276. <Id>5601</Id>
  277. <Message LcId="1033">SAFEOUT-Module:{0}: Overcurrent detected; Counter:0x{1,x}</Message>
  278. </Event>
  279. <Event>
  280. <Id>8193</Id>
  281. <Message LcId="1033">The {0}. connection has received an invalid FSoE-Cmd in state CONNECTION</Message>
  282. </Event>
  283. <Event>
  284. <Id>8194</Id>
  285. <Message LcId="1033">The {0}. connection has received an unknown FSoE-Cmd in state CONNECTION</Message>
  286. </Event>
  287. <Event>
  288. <Id>8195</Id>
  289. <Message LcId="1033">The {0}. connection has received an invalid FSoE-ConnID in state CONNECTION</Message>
  290. </Event>
  291. <Event>
  292. <Id>8196</Id>
  293. <Message LcId="1033">The {0}. connection has received an invalid FSoE-CRC in state CONNECTION</Message>
  294. </Event>
  295. <Event>
  296. <Id>8197</Id>
  297. <Message LcId="1033">The FSoE-Watchdog of the {0}. connection has been expired in state CONNECTION</Message>
  298. </Event>
  299. <Event>
  300. <Id>8198</Id>
  301. <Message LcId="1033">On the {0}. connection the received FSoE-Address (0x{1,x}) does not match with the expected FSoE-Address (0x{2,x})</Message>
  302. </Event>
  303. <Event>
  304. <Id>8199</Id>
  305. <Message LcId="1033">On the {0}. connection the received connection data do not match with the sent values</Message>
  306. </Event>
  307. <Event>
  308. <Id>8204</Id>
  309. <Message LcId="1033">On the {0}. connection in state CONNECTION the Connection was restarted from the FSoE-Master</Message>
  310. </Event>
  311. <Event>
  312. <Id>8206</Id>
  313. <Message LcId="1033">A Module fault was detected on the {0}. connection in state CONNECTION</Message>
  314. </Event>
  315. <Event>
  316. <Id>8209</Id>
  317. <Message LcId="1033">On the {0}. connection in state CONNECTION a FSoE-Reset with Error-Code 1 was received which means that the communication partner has received an invalid FSoE-Cmd</Message>
  318. </Event>
  319. <Event>
  320. <Id>8210</Id>
  321. <Message LcId="1033">On the {0}. connection in state CONNECTION a FSoE-Reset with Error-Code 2 was received which means that the communication partner has received an unknown FSoE-Cmd</Message>
  322. </Event>
  323. <Event>
  324. <Id>8211</Id>
  325. <Message LcId="1033">On the {0}. connection in state CONNECTION a FSoE-Reset with Error-Code 3 was received which means that the communication partner has received an invalid FSoE-ConnID</Message>
  326. </Event>
  327. <Event>
  328. <Id>8212</Id>
  329. <Message LcId="1033">On the {0}. connection in state CONNECTION a FSoE-Reset with Error-Code 4 was received which means that the communication partner has received an invalid FSoE-CRC</Message>
  330. </Event>
  331. <Event>
  332. <Id>8213</Id>
  333. <Message LcId="1033">On the {0}. connection in state CONNECTION a FSoE-Reset with Error-Code 5 was received which means that the FSoE-Watchdog has been expired in the communication partner</Message>
  334. </Event>
  335. <Event>
  336. <Id>8214</Id>
  337. <Message LcId="1033">On the {0}. connection in state CONNECTION a FSoE-Reset with Error-Code 6 was received which means that the communication partner has received an invalid FSoE-Address</Message>
  338. </Event>
  339. <Event>
  340. <Id>8215</Id>
  341. <Message LcId="1033">On the {0}. connection in state CONNECTION a FSoE-Reset with Error-Code 7 was received which means that the communication partner has received connection data do not match with the sent values</Message>
  342. </Event>
  343. <Event>
  344. <Id>8216</Id>
  345. <Message LcId="1033">On the {0}. connection in state CONNECTION a FSoE-Reset with Error-Code 8 was received which means that the communication partner has received an invalid communication parameter length</Message>
  346. </Event>
  347. <Event>
  348. <Id>8217</Id>
  349. <Message LcId="1033">On the {0}. connection in state CONNECTION a FSoE-Reset with Error-Code 9 was received which means that the communication partner has received an invalid FSoE Watchdog</Message>
  350. </Event>
  351. <Event>
  352. <Id>8218</Id>
  353. <Message LcId="1033">On the {0}. connection in state CONNECTION a FSoE-Reset with Error-Code 10 was received which means that the communication partner has received an invalid application parameter length</Message>
  354. </Event>
  355. <Event>
  356. <Id>8219</Id>
  357. <Message LcId="1033">On the {0}. connection in state CONNECTION a FSoE-Reset with Error-Code 11 was received which means that the communication partner has received invalid application parameter data</Message>
  358. </Event>
  359. <Event>
  360. <Id>8220</Id>
  361. <Message LcId="1033">On the {0}. connection in state CONNECTION a FSoE-Reset with Error-Code 12 was received</Message>
  362. </Event>
  363. <Event>
  364. <Id>8221</Id>
  365. <Message LcId="1033">On the {0}. connection in state CONNECTION a FSoE-Reset with Error-Code 13 was received</Message>
  366. </Event>
  367. <Event>
  368. <Id>8222</Id>
  369. <Message LcId="1033">On the {0}. connection in state CONNECTION a FSoE-Reset with Error-Code 14 was received which means that the communication partner has detected a module fault</Message>
  370. </Event>
  371. <Event>
  372. <Id>8223</Id>
  373. <Message LcId="1033">On the {0}. connection in state CONNECTION a FSoE-Reset with Error-Code 0x{1,x} was received</Message>
  374. </Event>
  375. <Event>
  376. <Id>8257</Id>
  377. <Message LcId="1033">The {0}. connection has received an invalid FSoE-Cmd in state PARAMETER</Message>
  378. </Event>
  379. <Event>
  380. <Id>8258</Id>
  381. <Message LcId="1033">The {0}. connection has received an unknown FSoE-Cmd in state PARAMETER</Message>
  382. </Event>
  383. <Event>
  384. <Id>8259</Id>
  385. <Message LcId="1033">The {0}. connection has received an invalid FSoE-ConnID in state PARAMETER</Message>
  386. </Event>
  387. <Event>
  388. <Id>8260</Id>
  389. <Message LcId="1033">The {0}. connection has received an invalid FSoE-CRC in state PARAMETER</Message>
  390. </Event>
  391. <Event>
  392. <Id>8261</Id>
  393. <Message LcId="1033">The FSoE-Watchdog of the {0}. connection has been expired in state PARAMETER</Message>
  394. </Event>
  395. <Event>
  396. <Id>8263</Id>
  397. <Message LcId="1033">On the {0}. connection the received parameter data do not match with the sent values</Message>
  398. </Event>
  399. <Event>
  400. <Id>8264</Id>
  401. <Message LcId="1033">On the {0}. connection the received communication parameter length ({1}) does not match with the expected value of 2</Message>
  402. </Event>
  403. <Event>
  404. <Id>8265</Id>
  405. <Message LcId="1033">On the {0}. connection the received FSoE Watchdog ({1}) is outside the allowed area from 2 to 60000</Message>
  406. </Event>
  407. <Event>
  408. <Id>8266</Id>
  409. <Message LcId="1033">On the {0}. connection the received application parameter length ({1}) is unequal the expected length of {2}</Message>
  410. </Event>
  411. <Event>
  412. <Id>8267</Id>
  413. <Message LcId="1033">On the {0}. connection the received application parameter data are wrong</Message>
  414. </Event>
  415. <Event>
  416. <Id>8268</Id>
  417. <Message LcId="1033">On the {0}. connection in state PARAMETER the Connection was restarted from the FSoE-Master</Message>
  418. </Event>
  419. <Event>
  420. <Id>8270</Id>
  421. <Message LcId="1033">A Module fault was detected on the {0}. connection in state PARAMETER</Message>
  422. </Event>
  423. <Event>
  424. <Id>8273</Id>
  425. <Message LcId="1033">On the {0}. connection in state PARAMETER a FSoE-Reset with Error-Code 1 was received which means that the communication partner has received an invalid FSoE-Cmd</Message>
  426. </Event>
  427. <Event>
  428. <Id>8274</Id>
  429. <Message LcId="1033">On the {0}. connection in state PARAMETER a FSoE-Reset with Error-Code 2 was received which means that the communication partner has received an unknown FSoE-Cmd</Message>
  430. </Event>
  431. <Event>
  432. <Id>8275</Id>
  433. <Message LcId="1033">On the {0}. connection in state PARAMETER a FSoE-Reset with Error-Code 3 was received which means that the communication partner has received an invalid FSoE-ConnID</Message>
  434. </Event>
  435. <Event>
  436. <Id>8276</Id>
  437. <Message LcId="1033">On the {0}. connection in state PARAMETER a FSoE-Reset with Error-Code 4 was received which means that the communication partner has received an invalid FSoE-CRC</Message>
  438. </Event>
  439. <Event>
  440. <Id>8277</Id>
  441. <Message LcId="1033">On the {0}. connection in state PARAMETER a FSoE-Reset with Error-Code 5 was received which means that the FSoE-Watchdog has been expired in the communication partner</Message>
  442. </Event>
  443. <Event>
  444. <Id>8278</Id>
  445. <Message LcId="1033">On the {0}. connection in state PARAMETER a FSoE-Reset with Error-Code 6 was received which means that the communication partner has received an invalid FSoE-Address</Message>
  446. </Event>
  447. <Event>
  448. <Id>8279</Id>
  449. <Message LcId="1033">On the {0}. connection in state PARAMETER a FSoE-Reset with Error-Code 7 was received which means that the communication partner has received connection data do not match with the sent values</Message>
  450. </Event>
  451. <Event>
  452. <Id>8280</Id>
  453. <Message LcId="1033">On the {0}. connection in state PARAMETER a FSoE-Reset with Error-Code 8 was received which means that the communication partner has received an invalid communication parameter length</Message>
  454. </Event>
  455. <Event>
  456. <Id>8281</Id>
  457. <Message LcId="1033">On the {0}. connection in state PARAMETER a FSoE-Reset with Error-Code 9 was received which means that the communication partner has received an invalid FSoE Watchdog</Message>
  458. </Event>
  459. <Event>
  460. <Id>8282</Id>
  461. <Message LcId="1033">On the {0}. connection in state PARAMETER a FSoE-Reset with Error-Code 10 was received which means that the communication partner has received an invalid application parameter length</Message>
  462. </Event>
  463. <Event>
  464. <Id>8283</Id>
  465. <Message LcId="1033">On the {0}. connection in state PARAMETER a FSoE-Reset with Error-Code 11 was received which means that the communication partner has received invalid application parameter data</Message>
  466. </Event>
  467. <Event>
  468. <Id>8284</Id>
  469. <Message LcId="1033">On the {0}. connection in state PARAMETER a FSoE-Reset with Error-Code 12 was received</Message>
  470. </Event>
  471. <Event>
  472. <Id>8285</Id>
  473. <Message LcId="1033">On the {0}. connection in state PARAMETER a FSoE-Reset with Error-Code 13 was received</Message>
  474. </Event>
  475. <Event>
  476. <Id>8286</Id>
  477. <Message LcId="1033">On the {0}. connection in state PARAMETER a FSoE-Reset with Error-Code 14 was received which means that the communication partner has detected a module fault</Message>
  478. </Event>
  479. <Event>
  480. <Id>8287</Id>
  481. <Message LcId="1033">On the {0}. connection in state PARAMETER a FSoE-Reset with Error-Code 0x{1,x} was received</Message>
  482. </Event>
  483. <Event>
  484. <Id>8289</Id>
  485. <Message LcId="1033">On the {0}. connection in state PARAMETER a wrong Command was received, which means that the Safe-Parameter size is wrong (Expected size: {1}, Received size: {2})</Message>
  486. </Event>
  487. <Event>
  488. <Id>8321</Id>
  489. <Message LcId="1033">The {0}. connection has received an invalid FSoE-Cmd in state DATA</Message>
  490. </Event>
  491. <Event>
  492. <Id>8322</Id>
  493. <Message LcId="1033">The {0}. connection has received an unknown FSoE-Cmd in state DATA</Message>
  494. </Event>
  495. <Event>
  496. <Id>8323</Id>
  497. <Message LcId="1033">The {0}. connection has received an invalid FSoE-ConnID in state DATA</Message>
  498. </Event>
  499. <Event>
  500. <Id>8324</Id>
  501. <Message LcId="1033">The {0}. connection has received an invalid FSoE-CRC in state DATA</Message>
  502. </Event>
  503. <Event>
  504. <Id>8325</Id>
  505. <Message LcId="1033">The FSoE-Watchdog of the {0}. connection has been expired in state DATA</Message>
  506. </Event>
  507. <Event>
  508. <Id>8332</Id>
  509. <Message LcId="1033">On the {0}. connection in state DATA the Connection was restarted from the FSoE-Master</Message>
  510. </Event>
  511. <Event>
  512. <Id>8333</Id>
  513. <Message LcId="1033">The FailSafeData command was received on the {0}. connection in state DATA</Message>
  514. </Event>
  515. <Event>
  516. <Id>8334</Id>
  517. <Message LcId="1033">A Module fault was detected on the {0}. connection in state DATA</Message>
  518. </Event>
  519. <Event>
  520. <Id>8337</Id>
  521. <Message LcId="1033">On the {0}. connection in state DATA a FSoE-Reset with Error-Code 1 was received which means that the communication partner has received an invalid FSoE-Cmd</Message>
  522. </Event>
  523. <Event>
  524. <Id>8338</Id>
  525. <Message LcId="1033">On the {0}. connection in state DATA a FSoE-Reset with Error-Code 2 was received which means that the communication partner has received an unknown FSoE-Cmd</Message>
  526. </Event>
  527. <Event>
  528. <Id>8339</Id>
  529. <Message LcId="1033">On the {0}. connection in state DATA a FSoE-Reset with Error-Code 3 was received which means that the communication partner has received an invalid FSoE-ConnID</Message>
  530. </Event>
  531. <Event>
  532. <Id>8340</Id>
  533. <Message LcId="1033">On the {0}. connection in state DATA a FSoE-Reset with Error-Code 4 was received which means that the communication partner has received an invalid FSoE-CRC</Message>
  534. </Event>
  535. <Event>
  536. <Id>8341</Id>
  537. <Message LcId="1033">On the {0}. connection in state DATA a FSoE-Reset with Error-Code 5 was received which means that the FSoE-Watchdog has been expired in the communication partner</Message>
  538. </Event>
  539. <Event>
  540. <Id>8342</Id>
  541. <Message LcId="1033">On the {0}. connection in state DATA a FSoE-Reset with Error-Code 6 was received which means that the communication partner has received an invalid FSoE-Address</Message>
  542. </Event>
  543. <Event>
  544. <Id>8343</Id>
  545. <Message LcId="1033">On the {0}. connection in state DATA a FSoE-Reset with Error-Code 7 was received which means that the communication partner has received connection data do not match with the sent values</Message>
  546. </Event>
  547. <Event>
  548. <Id>8344</Id>
  549. <Message LcId="1033">On the {0}. connection in state DATA a FSoE-Reset with Error-Code 8 was received which means that the communication partner has received an invalid communication parameter length</Message>
  550. </Event>
  551. <Event>
  552. <Id>8345</Id>
  553. <Message LcId="1033">On the {0}. connection in state DATA a FSoE-Reset with Error-Code 9 was received which means that the communication partner has received an invalid FSoE Watchdog</Message>
  554. </Event>
  555. <Event>
  556. <Id>8346</Id>
  557. <Message LcId="1033">On the {0}. connection in state DATA a FSoE-Reset with Error-Code 10 was received which means that the communication partner has received an invalid application parameter length</Message>
  558. </Event>
  559. <Event>
  560. <Id>8347</Id>
  561. <Message LcId="1033">On the {0}. connection in state DATA a FSoE-Reset with Error-Code 11 was received which means that the communication partner has received invalid application parameter data</Message>
  562. </Event>
  563. <Event>
  564. <Id>8348</Id>
  565. <Message LcId="1033">On the {0}. connection in state DATA a FSoE-Reset with Error-Code 12 was received</Message>
  566. </Event>
  567. <Event>
  568. <Id>8349</Id>
  569. <Message LcId="1033">On the {0}. connection in state DATA a FSoE-Reset with Error-Code 13 was received</Message>
  570. </Event>
  571. <Event>
  572. <Id>8350</Id>
  573. <Message LcId="1033">On the {0}. connection in state DATA a FSoE-Reset with Error-Code 14 was received which means that the communication partner has detected a module fault</Message>
  574. </Event>
  575. <Event>
  576. <Id>8351</Id>
  577. <Message LcId="1033">On the {0}. connection in state DATA a FSoE-Reset with Error-Code 0x{1,x} was received</Message>
  578. </Event>
  579. <Event>
  580. <Id>8385</Id>
  581. <Message LcId="1033">The {0}. connection has received an invalid FSoE-Cmd in state SHUTDOWN</Message>
  582. </Event>
  583. <Event>
  584. <Id>8386</Id>
  585. <Message LcId="1033">The {0}. connection has received an unknown FSoE-Cmd in state SHUTDOWN</Message>
  586. </Event>
  587. <Event>
  588. <Id>8388</Id>
  589. <Message LcId="1033">The {0}. connection has received an invalid FSoE-CRC in state SHUTDOWN</Message>
  590. </Event>
  591. <Event>
  592. <Id>8419</Id>
  593. <Message LcId="1033">The {0}. connection has received the invalid FSoE-ConnID 0 in state SESSION</Message>
  594. </Event>
  595. <Event>
  596. <Id>8449</Id>
  597. <Message LcId="1033">On the {0}. connection the PROFIsafe-Slave reports a communication error</Message>
  598. </Event>
  599. <Event>
  600. <Id>8450</Id>
  601. <Message LcId="1033">On the {0}. connection the PROFIsafe-Slave reports a watchdog error</Message>
  602. </Event>
  603. <Event>
  604. <Id>8451</Id>
  605. <Message LcId="1033">On the {0}. connection the PROFIsafe-Slave reports a device fault</Message>
  606. </Event>
  607. <Event>
  608. <Id>8452</Id>
  609. <Message LcId="1033">On the {0}. connection a CRC2-Error was detected locally on the PROFIsafe Host</Message>
  610. </Event>
  611. <Event>
  612. <Id>8453</Id>
  613. <Message LcId="1033">On the {0}. connection the Watchdog has been expired locally on the PROFIsafe Host</Message>
  614. </Event>
  615. <Event>
  616. <Id>8468</Id>
  617. <Message LcId="1033">On the {0}. connection a CRC2-Error was detected locally on the PROFIsafe Slave</Message>
  618. </Event>
  619. <Event>
  620. <Id>8469</Id>
  621. <Message LcId="1033">On the {0}. connection the Watchdog has been expired locally on the PROFIsafe Slave</Message>
  622. </Event>
  623. <Event>
  624. <Id>8471</Id>
  625. <Message LcId="1033">On the {0}. connection the Bit 7 of the F_Control is reset, which is not allowed on a PROFIsafe Slave connection with the same message size for inputs and outputs</Message>
  626. </Event>
  627. <Event>
  628. <Id>8476</Id>
  629. <Message LcId="1033">On the {0}. connection the PROFIsafe Slave has been restarted locally</Message>
  630. </Event>
  631. <Event>
  632. <Id>12288</Id>
  633. <Message LcId="1033">The received number of groups ({0}) was too big, the maximum allowed value is {1}</Message>
  634. </Event>
  635. <Event>
  636. <Id>12289</Id>
  637. <Message LcId="1033">The received number of FBs ({0}) was too big, the maximum allowed value is {1}</Message>
  638. </Event>
  639. <Event>
  640. <Id>12290</Id>
  641. <Message LcId="1033">The received number of Connections ({0}) was too big, the maximum allowed value is {1}</Message>
  642. </Event>
  643. <Event>
  644. <Id>12291</Id>
  645. <Message LcId="1033">The received number of Output Mappings was too big, the maximum allowed value is {0}</Message>
  646. </Event>
  647. <Event>
  648. <Id>12292</Id>
  649. <Message LcId="1033">The received number of Input Mappings was too big, the maximum allowed value is {0}</Message>
  650. </Event>
  651. <Event>
  652. <Id>12293</Id>
  653. <Message LcId="1033">The received size of Standard Inputs ({0}) was too big, the maximum allowed value is {1}</Message>
  654. </Event>
  655. <Event>
  656. <Id>12294</Id>
  657. <Message LcId="1033">The received size of Standard Outputs ({0}) was too big, the maximum allowed value is {1}</Message>
  658. </Event>
  659. <Event>
  660. <Id>12295</Id>
  661. <Message LcId="1033">The received number of Restore Slaves ({0}) was too big, the maximum allowed value is {1}</Message>
  662. </Event>
  663. <Event>
  664. <Id>12296</Id>
  665. <Message LcId="1033">The SafeCfgData type was unexpected: {0} found and {1} expected</Message>
  666. </Event>
  667. <Event>
  668. <Id>12297</Id>
  669. <Message LcId="1033">The SafeCfgData type 2 (Connection) was expected at offset {0}</Message>
  670. </Event>
  671. <Event>
  672. <Id>12298</Id>
  673. <Message LcId="1033">The SafeCfgData type 3 (FB) was expected at offset {0}</Message>
  674. </Event>
  675. <Event>
  676. <Id>12299</Id>
  677. <Message LcId="1033">The SafeCfgData type 15 (GAP) was expected at offset {0}</Message>
  678. </Event>
  679. <Event>
  680. <Id>12300</Id>
  681. <Message LcId="1033">The Bit-Mask in the SafeCfgData was wrong at offset {0}</Message>
  682. </Event>
  683. <Event>
  684. <Id>12301</Id>
  685. <Message LcId="1033">The address in the SafeCfgData was wrong at offset {0}</Message>
  686. </Event>
  687. <Event>
  688. <Id>12302</Id>
  689. <Message LcId="1033">The Signal number in the SafeCfgData was wrong at offset {0}</Message>
  690. </Event>
  691. <Event>
  692. <Id>12303</Id>
  693. <Message LcId="1033">The number of connections was wrong in the SafeCfgData of the Group at offset {0}</Message>
  694. </Event>
  695. <Event>
  696. <Id>12304</Id>
  697. <Message LcId="1033">The number of FBs was wrong in the SafeCfgData of the Group at offset {0}</Message>
  698. </Event>
  699. <Event>
  700. <Id>12305</Id>
  701. <Message LcId="1033">The size of the SafeCfgData was wrong at offset {0}</Message>
  702. </Event>
  703. <Event>
  704. <Id>12306</Id>
  705. <Message LcId="1033">The complete size of the SafeCfgData related to the Group {0} was wrong</Message>
  706. </Event>
  707. <Event>
  708. <Id>12307</Id>
  709. <Message LcId="1033">If the RUN-Signal should be mapped internally, it has to be activated at offset {0}</Message>
  710. </Event>
  711. <Event>
  712. <Id>12308</Id>
  713. <Message LcId="1033">The message size at offset {0} is invalid</Message>
  714. </Event>
  715. <Event>
  716. <Id>12309</Id>
  717. <Message LcId="1033">The connection parameter at offset {0} is invalid</Message>
  718. </Event>
  719. <Event>
  720. <Id>12310</Id>
  721. <Message LcId="1033">If the ERRACK-Signal should be mapped internally, it has to be activated at offset {0}</Message>
  722. </Event>
  723. <Event>
  724. <Id>12311</Id>
  725. <Message LcId="1033">The connection type at offset {0} is invalid</Message>
  726. </Event>
  727. <Event>
  728. <Id>12312</Id>
  729. <Message LcId="1033">The value at offset {0} of the SafeCfgData is invalid</Message>
  730. </Event>
  731. <Event>
  732. <Id>12313</Id>
  733. <Message LcId="1033">The value at offset {0} of the SafeCfgData is invalid because at least one of the related signals is not active</Message>
  734. </Event>
  735. <Event>
  736. <Id>12314</Id>
  737. <Message LcId="1033">The number of mappings ({0}) is wrong because it is not the last Mapping SafeCfgData</Message>
  738. </Event>
  739. <Event>
  740. <Id>12315</Id>
  741. <Message LcId="1033">The Safe Logic Cfg Data were downloaded in the wrong download state ({0})</Message>
  742. </Event>
  743. <Event>
  744. <Id>12316</Id>
  745. <Message LcId="1033">The number of mappings ({0}) is too great in the Mapping SafeCfgData</Message>
  746. </Event>
  747. <Event>
  748. <Id>12317</Id>
  749. <Message LcId="1033">The Mapping-Size in the SafeCfgData was wrong at offset {0}</Message>
  750. </Event>
  751. <Event>
  752. <Id>12318</Id>
  753. <Message LcId="1033">A Group-Input Mapping was expected at offset {0}</Message>
  754. </Event>
  755. <Event>
  756. <Id>12319</Id>
  757. <Message LcId="1033">A Connection-Input Mapping was expected at offset {0}</Message>
  758. </Event>
  759. <Event>
  760. <Id>12320</Id>
  761. <Message LcId="1033">A FB-Input Bit-Mapping was expected at offset {0}</Message>
  762. </Event>
  763. <Event>
  764. <Id>12321</Id>
  765. <Message LcId="1033">A FB-Input Byte-Mapping was expected at offset {0}</Message>
  766. </Event>
  767. <Event>
  768. <Id>12322</Id>
  769. <Message LcId="1033">No more mapping was expected at offset {0}</Message>
  770. </Event>
  771. <Event>
  772. <Id>12323</Id>
  773. <Message LcId="1033">Invalid Safe User Parameter size at byte offset 0x{0,x} (Found={1}, Expected={2})</Message>
  774. </Event>
  775. <Event>
  776. <Id>12324</Id>
  777. <Message LcId="1033">The SafeCfgData type 4 (Safe User Parameter) was expected at offset {0}</Message>
  778. </Event>
  779. <Event>
  780. <Id>12325</Id>
  781. <Message LcId="1033">The download of the Input Mapping Cfg Data was refused because {0} groups were missing in the Safe Logic Cfg Data</Message>
  782. </Event>
  783. <Event>
  784. <Id>12326</Id>
  785. <Message LcId="1033">The download of the Input Mapping Cfg Data was refused because {0} connections were missing in the Safe Logic Cfg Data</Message>
  786. </Event>
  787. <Event>
  788. <Id>12327</Id>
  789. <Message LcId="1033">The download of the Input Mapping Cfg Data was refused because {0} FBs were missing in the Safe Logic Cfg Data</Message>
  790. </Event>
  791. <Event>
  792. <Id>12328</Id>
  793. <Message LcId="1033">At least one group has to be defined in the SafeCfgData</Message>
  794. </Event>
  795. <Event>
  796. <Id>12329</Id>
  797. <Message LcId="1033">The download of the Input Mapping Cfg Data was refused because no safe Logic Cfg Data were downloaded before</Message>
  798. </Event>
  799. <Event>
  800. <Id>12330</Id>
  801. <Message LcId="1033">The Subindex {0} was expected to be downloaded</Message>
  802. </Event>
  803. <Event>
  804. <Id>12331</Id>
  805. <Message LcId="1033">When loading CfgData a user has to be logged in before</Message>
  806. </Event>
  807. <Event>
  808. <Id>12332</Id>
  809. <Message LcId="1033">The Input Mapping Cfg Data were downloaded in the wrong download state ({0})</Message>
  810. </Event>
  811. <Event>
  812. <Id>12333</Id>
  813. <Message LcId="1033">The download of theSafe Logic CfgData is refused because the old Safe Logic Cfg Data were not deleted before</Message>
  814. </Event>
  815. <Event>
  816. <Id>12334</Id>
  817. <Message LcId="1033">The user was logged out before</Message>
  818. </Event>
  819. <Event>
  820. <Id>12335</Id>
  821. <Message LcId="1033">The user has not sufficient access rights</Message>
  822. </Event>
  823. <Event>
  824. <Id>12336</Id>
  825. <Message LcId="1033">The reserved area of the CfgData was not 0</Message>
  826. </Event>
  827. <Event>
  828. <Id>12337</Id>
  829. <Message LcId="1033">The CRC of the CfgData was wrong</Message>
  830. </Event>
  831. <Event>
  832. <Id>12338</Id>
  833. <Message LcId="1033">All needed CfgData pages were downloaded before, no more pages are expected</Message>
  834. </Event>
  835. <Event>
  836. <Id>12339</Id>
  837. <Message LcId="1033">The mapping code buffer is too small for the mapping (Offset: 0x{0,x}, Size: {1})</Message>
  838. </Event>
  839. <Event>
  840. <Id>12340</Id>
  841. <Message LcId="1033">The maximum allowed subindex is {0}</Message>
  842. </Event>
  843. <Event>
  844. <Id>12341</Id>
  845. <Message LcId="1033">The download of the Output Mapping Cfg Data was refused because {0} mappings of the Input Mapping Cfg Data were missing</Message>
  846. </Event>
  847. <Event>
  848. <Id>12342</Id>
  849. <Message LcId="1033">{0} input mappings of the groups were missing in the Input Mapping Cfg Data</Message>
  850. </Event>
  851. <Event>
  852. <Id>12343</Id>
  853. <Message LcId="1033">{0} input mappings of the connections were missing in the Input Mapping Cfg Data</Message>
  854. </Event>
  855. <Event>
  856. <Id>12344</Id>
  857. <Message LcId="1033">{0} input bit mappings of the FBs were missing in the Input Mapping Cfg Data</Message>
  858. </Event>
  859. <Event>
  860. <Id>12345</Id>
  861. <Message LcId="1033">{0} input byte mappings of the FBs were missing in the Input Mapping Cfg Data</Message>
  862. </Event>
  863. <Event>
  864. <Id>12346</Id>
  865. <Message LcId="1033">The Output Mapping Cfg Data were downloaded in the wrong download state ({0})</Message>
  866. </Event>
  867. <Event>
  868. <Id>12347</Id>
  869. <Message LcId="1033">The mapping code buffer is too small for the local mapping</Message>
  870. </Event>
  871. <Event>
  872. <Id>12348</Id>
  873. <Message LcId="1033">The download of the Safe Parameter was refused because no Output Mapping Cfg Data were downloaded before</Message>
  874. </Event>
  875. <Event>
  876. <Id>12349</Id>
  877. <Message LcId="1033">The download of the Safe User Parameter was refused because {0} mappings of the Output Mapping Cfg Data were missing</Message>
  878. </Event>
  879. <Event>
  880. <Id>12350</Id>
  881. <Message LcId="1033">The Safe User Parameter Cfg Data were downloaded in the wrong download state ({0})</Message>
  882. </Event>
  883. <Event>
  884. <Id>12351</Id>
  885. <Message LcId="1033">The download of the Activate Project Cfg Data was refused because no Safe User Parameter Cfg Data were downloaded before</Message>
  886. </Event>
  887. <Event>
  888. <Id>12352</Id>
  889. <Message LcId="1033">The download of the Activate Project Cfg Data was refused because {0} bytes of the Safe Parameter Cfg Data were missing</Message>
  890. </Event>
  891. <Event>
  892. <Id>12353</Id>
  893. <Message LcId="1033">The received activate code (0x{0,x}) was wrong in the Project Cfg Data</Message>
  894. </Event>
  895. <Event>
  896. <Id>12354</Id>
  897. <Message LcId="1033">The TwinSAFE Address ({0}) in the Project Cfg Data does not match with the DIP switch ({1})</Message>
  898. </Event>
  899. <Event>
  900. <Id>12355</Id>
  901. <Message LcId="1033">At least one Cfg Data page has to be defined in the Safe Logic Cfg Data</Message>
  902. </Event>
  903. <Event>
  904. <Id>12356</Id>
  905. <Message LcId="1033">The maximum number ({0}) of Cfg Data pages was exceeded in the Safe Logic Cfg Data</Message>
  906. </Event>
  907. <Event>
  908. <Id>12357</Id>
  909. <Message LcId="1033">The received number of Safe Logic Cfg Data pages ({0}) has exceeded the configured value at offset 0 of the Safe Logic Cfg Data ({1})</Message>
  910. </Event>
  911. <Event>
  912. <Id>12358</Id>
  913. <Message LcId="1033">The download of the Input Mapping Cfg Data was refused because {0} pages were missing in the Safe Logic Cfg Data</Message>
  914. </Event>
  915. <Event>
  916. <Id>12359</Id>
  917. <Message LcId="1033">The Safe Logic Cfg Data CRC does not match in the Safe Project Cfg Data</Message>
  918. </Event>
  919. <Event>
  920. <Id>12360</Id>
  921. <Message LcId="1033">When checking the Mapping Code a fault has detected at offset 0x{0,x}</Message>
  922. </Event>
  923. <Event>
  924. <Id>12361</Id>
  925. <Message LcId="1033">The Mapping Cfg Data CRC does not match in the Safe Project Cfg Data</Message>
  926. </Event>
  927. <Event>
  928. <Id>12362</Id>
  929. <Message LcId="1033">The number of Input Mappings is too small in the Safe Project Cfg Data (Code-Offset=0x{0,x})</Message>
  930. </Event>
  931. <Event>
  932. <Id>12363</Id>
  933. <Message LcId="1033">The number of Output Mappings is too small in the Safe Project Cfg Data (Code-Offset=0x{0,x})</Message>
  934. </Event>
  935. <Event>
  936. <Id>12364</Id>
  937. <Message LcId="1033">The number of Input Mappings is too great in the Safe Project Cfg Data, ({0} mappings too much, Code-Offset=0x{1,x})</Message>
  938. </Event>
  939. <Event>
  940. <Id>12365</Id>
  941. <Message LcId="1033">The number of Output Mappings is too great in the Safe Project Cfg Data, ({0} mappings too much, Code-Offset=0x{1,x})</Message>
  942. </Event>
  943. <Event>
  944. <Id>12366</Id>
  945. <Message LcId="1033">The maximum number ({0}) of Cfg Data pages was exceeded in the Safe User Parameter Cfg Data</Message>
  946. </Event>
  947. <Event>
  948. <Id>12367</Id>
  949. <Message LcId="1033">At least one Cfg Data page has to be defined in the Safe User Parameter Cfg Data</Message>
  950. </Event>
  951. <Event>
  952. <Id>12368</Id>
  953. <Message LcId="1033">The Safe User Parameter Cfg Data CRC does not match in the Safe Project Cfg Data</Message>
  954. </Event>
  955. <Event>
  956. <Id>12370</Id>
  957. <Message LcId="1033">The calculated local process image size ({0}) exceeded the maximum local process image size of {1}</Message>
  958. </Event>
  959. <Event>
  960. <Id>12371</Id>
  961. <Message LcId="1033">The Activate Project Cfg Data were downloaded in the wrong download state ({0})</Message>
  962. </Event>
  963. <Event>
  964. <Id>12372</Id>
  965. <Message LcId="1033">The Delete Project Cfg Data were downloaded in the wrong download state ({0})</Message>
  966. </Event>
  967. <Event>
  968. <Id>12373</Id>
  969. <Message LcId="1033">The TwinSAFE Address ({0}) does not match with the DIP switch ({1}) in the Delete Project Cfg Data</Message>
  970. </Event>
  971. <Event>
  972. <Id>12374</Id>
  973. <Message LcId="1033">The Delete Code ({0}) is too high in the Delete Project Cfg Data</Message>
  974. </Event>
  975. <Event>
  976. <Id>12375</Id>
  977. <Message LcId="1033">Unexpected connection index in the Safe User Parameter Cfg Data at byte offset 0x{0,x}</Message>
  978. </Event>
  979. <Event>
  980. <Id>12376</Id>
  981. <Message LcId="1033">The received number of Local Safety Inputs ({0}) was wrong, the expected value is {1}</Message>
  982. </Event>
  983. <Event>
  984. <Id>12377</Id>
  985. <Message LcId="1033">The received number of Local Safety Outputs ({0}) was wrong, the expected value is {1}</Message>
  986. </Event>
  987. <Event>
  988. <Id>12378</Id>
  989. <Message LcId="1033">The received number of Local Standard Inputs ({0}) was wrong, the expected value is {1}</Message>
  990. </Event>
  991. <Event>
  992. <Id>12379</Id>
  993. <Message LcId="1033">The received number of Local Standard Outputs ({0}) was wrong, the expected value is {1}</Message>
  994. </Event>
  995. <Event>
  996. <Id>12380</Id>
  997. <Message LcId="1033">The received Safety Input Message size at word offset 15 of the Safe Logic Cfg Data ({0}) is unequal the calculated value of {1}</Message>
  998. </Event>
  999. <Event>
  1000. <Id>12381</Id>
  1001. <Message LcId="1033">The received Safety Output Message size at word offset 16 of the Safe Logic Cfg Data ({0}) is unequal the calculated value of {1}</Message>
  1002. </Event>
  1003. <Event>
  1004. <Id>12382</Id>
  1005. <Message LcId="1033">The received Safety Input size at word offset 7 of the Safe Logic Cfg Data ({0}) is unequal the calculated value of {1}</Message>
  1006. </Event>
  1007. <Event>
  1008. <Id>12383</Id>
  1009. <Message LcId="1033">The received Safety Output size at word offset 8 of the Safe Logic Cfg Data ({0}) is unequal the calculated value of {1}</Message>
  1010. </Event>
  1011. <Event>
  1012. <Id>12384</Id>
  1013. <Message LcId="1033">The received PROFIsafe Input Message size at word offset 9 of the Safe Logic Cfg Data ({0}) is unequal the calculated value of {1}</Message>
  1014. </Event>
  1015. <Event>
  1016. <Id>12385</Id>
  1017. <Message LcId="1033">The received PROFIsafe Output Message size at word offset 10 of the Safe Logic Cfg Data ({0}) is unequal the calculated value of {1}</Message>
  1018. </Event>
  1019. <Event>
  1020. <Id>12386</Id>
  1021. <Message LcId="1033">At word offset 0x{0,x} the configured number of CRCs of {1} exceeds the maximum number of CRCs ({2})</Message>
  1022. </Event>
  1023. <Event>
  1024. <Id>12387</Id>
  1025. <Message LcId="1033">The received SafeUserParameterSizeInFrame ({0}) was wrong, the expected value is {1}</Message>
  1026. </Event>
  1027. <Event>
  1028. <Id>12388</Id>
  1029. <Message LcId="1033">The received FB Analog Input size at word offset 13 of the Safe Logic Cfg Data ({0}) is unequal the calculated value of {1}</Message>
  1030. </Event>
  1031. <Event>
  1032. <Id>12389</Id>
  1033. <Message LcId="1033">The received FB Analog Output size at word offset 14 of the Safe Logic Cfg Data ({0}) is unequal the calculated value of {1}</Message>
  1034. </Event>
  1035. <Event>
  1036. <Id>12390</Id>
  1037. <Message LcId="1033">The received Connection Status Data size at word offset 21 of the Safe Logic Cfg Data ({0}) is unequal the calculated value of {1}</Message>
  1038. </Event>
  1039. <Event>
  1040. <Id>12391</Id>
  1041. <Message LcId="1033">The received FB Status Data size at word offset 22 of the Safe Logic Cfg Data ({0}) is unequal the calculated value of {1}</Message>
  1042. </Event>
  1043. <Event>
  1044. <Id>12392</Id>
  1045. <Message LcId="1033">The number of active signals in the FB is invalid at offset {0}</Message>
  1046. </Event>
  1047. <Event>
  1048. <Id>12393</Id>
  1049. <Message LcId="1033">The local map code size in the FB is invalid at offset {0}</Message>
  1050. </Event>
  1051. <Event>
  1052. <Id>12394</Id>
  1053. <Message LcId="1033">The analog output size in the Group Cfg Data is invalid at offset {0}</Message>
  1054. </Event>
  1055. <Event>
  1056. <Id>12395</Id>
  1057. <Message LcId="1033">The analog output offset in the Group Cfg Data is invalid at offset {0}</Message>
  1058. </Event>
  1059. <Event>
  1060. <Id>12396</Id>
  1061. <Message LcId="1033">The received FB Analog Output size at word offset 14 of the Safe Logic Cfg Data ({0}) is unequal the calculated value over all the Group Cfg Data ({1})</Message>
  1062. </Event>
  1063. <Event>
  1064. <Id>12397</Id>
  1065. <Message LcId="1033">The calculated end of the analog output area ({0}) is unequal the calculated analog output offset over all the Group Cfg Data ({1})</Message>
  1066. </Event>
  1067. <Event>
  1068. <Id>12398</Id>
  1069. <Message LcId="1033">The value of the FB Cfg Data at offset {0} is invalid</Message>
  1070. </Event>
  1071. <Event>
  1072. <Id>12399</Id>
  1073. <Message LcId="1033">At least one FB input has to be deactivated in this operation mode at offset {0}</Message>
  1074. </Event>
  1075. <Event>
  1076. <Id>12400</Id>
  1077. <Message LcId="1033">At least the level of one FB input is wrong in this operation mode at offset {0}</Message>
  1078. </Event>
  1079. <Event>
  1080. <Id>12401</Id>
  1081. <Message LcId="1033">The value of the FB Cfg Data at word offset {0} is invalid in this operation mode</Message>
  1082. </Event>
  1083. <Event>
  1084. <Id>12402</Id>
  1085. <Message LcId="1033">The number ({0}) of Cfg Data pages was exceeded in the Info Data Cfg Data at offset 0</Message>
  1086. </Event>
  1087. <Event>
  1088. <Id>12403</Id>
  1089. <Message LcId="1033">The received number of FBs ({0}) at word offset 1 was unequal the configured number of FBs of {1}</Message>
  1090. </Event>
  1091. <Event>
  1092. <Id>12404</Id>
  1093. <Message LcId="1033">The received FB Status Data Size ({0}) in the Info Data Map Cfg Data at byte offset {1} is unequal the calculated FB Status Data size of {2}</Message>
  1094. </Event>
  1095. <Event>
  1096. <Id>12405</Id>
  1097. <Message LcId="1033">The received FB Diag Data Size ({0}) in the Info Data Map Cfg Data at byte offset {1} is unequal the calculated FB Diag Data size of {2}</Message>
  1098. </Event>
  1099. <Event>
  1100. <Id>12406</Id>
  1101. <Message LcId="1033">The received number of Connections ({0}) in the Info Data Cfg Data at word offset {1} was unequal the configured number of connections of {2}</Message>
  1102. </Event>
  1103. <Event>
  1104. <Id>12407</Id>
  1105. <Message LcId="1033">The received Connection Type ({0}) in the Info Data Map Cfg Data at byte offset {1} is unequal the configured Connection Type of {2}</Message>
  1106. </Event>
  1107. <Event>
  1108. <Id>12408</Id>
  1109. <Message LcId="1033">The FB Diag Data Map in the Info Data Map Cfg Data was wrong at byte offset {0} (bit 7=1 and bit 6=0 is not allowed)</Message>
  1110. </Event>
  1111. <Event>
  1112. <Id>12409</Id>
  1113. <Message LcId="1033">The received number of Groups ({0}) in the Info Data Cfg Data at word offset {1} was unequal the configured number of Groups of {2}</Message>
  1114. </Event>
  1115. <Event>
  1116. <Id>12410</Id>
  1117. <Message LcId="1033">The FB-Type is unknown at offset 0x{0,x}</Message>
  1118. </Event>
  1119. <Event>
  1120. <Id>12411</Id>
  1121. <Message LcId="1033">The value at offset {0} of the SafeCfgData is too great</Message>
  1122. </Event>
  1123. <Event>
  1124. <Id>12412</Id>
  1125. <Message LcId="1033">The value at offset {0} of the SafeCfgData is too small</Message>
  1126. </Event>
  1127. <Event>
  1128. <Id>12413</Id>
  1129. <Message LcId="1033">FB-Muting: if SequentialInputs is TRUE, all MuteIn signals have to be active at offset 0x{0,x}</Message>
  1130. </Event>
  1131. <Event>
  1132. <Id>12414</Id>
  1133. <Message LcId="1033">The type of the analog inputs has to be the same at offset 0x{0,x}</Message>
  1134. </Event>
  1135. <Event>
  1136. <Id>12415</Id>
  1137. <Message LcId="1033">The received size of the local safe user parameter ({0}) was wrong, the expected size is {1}</Message>
  1138. </Event>
  1139. <Event>
  1140. <Id>12416</Id>
  1141. <Message LcId="1033">The value at offset {0} of the SafeCfgData is invalid in combination with the value {1} words before in the SafeCfgData</Message>
  1142. </Event>
  1143. <Event>
  1144. <Id>12417</Id>
  1145. <Message LcId="1033">The received size of the FB Parameter Data at word offset 25 of the Safe Logic Cfg Data ({0}) is unequal the calculated value of {1}</Message>
  1146. </Event>
  1147. <Event>
  1148. <Id>12418</Id>
  1149. <Message LcId="1033">The FB-Type in the Change FB Parameter Data (FB {0}) is unequal, the expected FB-type is {1}</Message>
  1150. </Event>
  1151. <Event>
  1152. <Id>12419</Id>
  1153. <Message LcId="1033">The size in the Change FB Parameter Data (FB {0}) is unequal, the expected size is {1}</Message>
  1154. </Event>
  1155. <Event>
  1156. <Id>12420</Id>
  1157. <Message LcId="1033">The Setting Mode of the FB CAMMON (FB {0}) in the Change FB Parameter Data is not activated</Message>
  1158. </Event>
  1159. <Event>
  1160. <Id>12421</Id>
  1161. <Message LcId="1033">The actual Logic State ({0}) is unequal RUN (1) when changing FB Parameter Data</Message>
  1162. </Event>
  1163. <Event>
  1164. <Id>12422</Id>
  1165. <Message LcId="1033">The FB-Number ({0}) in the Change FB Parameter Data is invalid</Message>
  1166. </Event>
  1167. <Event>
  1168. <Id>12423</Id>
  1169. <Message LcId="1033">The FRAM data size ({0}) has exceeded, the maximum allowed value is {1}</Message>
  1170. </Event>
  1171. <Event>
  1172. <Id>12424</Id>
  1173. <Message LcId="1033">The Safe User Parameter in the Change FB Parameter Data are not supported</Message>
  1174. </Event>
  1175. <Event>
  1176. <Id>12425</Id>
  1177. <Message LcId="1033">The size ({0}) of the Change FB Parameter Data is too small, {1} bytes are expected</Message>
  1178. </Event>
  1179. <Event>
  1180. <Id>12426</Id>
  1181. <Message LcId="1033">The type ({0}) of the Safe User Parameter in the Change FB Parameter Data is wrong</Message>
  1182. </Event>
  1183. <Event>
  1184. <Id>12427</Id>
  1185. <Message LcId="1033">The size ({0}) of the Safe User Parameter in the Change FB Parameter Data is wrong, the expected size is {1}</Message>
  1186. </Event>
  1187. <Event>
  1188. <Id>12428</Id>
  1189. <Message LcId="1033">The offset of the Cyclic FRAM Data was wrong at offset {0}</Message>
  1190. </Event>
  1191. <Event>
  1192. <Id>12429</Id>
  1193. <Message LcId="1033">No Local Input bytes configured for Extended Info Data Mapping</Message>
  1194. </Event>
  1195. <Event>
  1196. <Id>12430</Id>
  1197. <Message LcId="1033">No Local Output bytes configured for Extended Info Data Mapping</Message>
  1198. </Event>
  1199. <Event>
  1200. <Id>12431</Id>
  1201. <Message LcId="1033">Too much Local Input bytes configured for Info Data, only 31 bytes are allowed</Message>
  1202. </Event>
  1203. <Event>
  1204. <Id>12432</Id>
  1205. <Message LcId="1033">Too much Local Output bytes configured for Info Data, only 31 bytes are allowed</Message>
  1206. </Event>
  1207. <Event>
  1208. <Id>12436</Id>
  1209. <Message LcId="1033">The size 0 is not allowed for the safe user parameter at word offset {0}</Message>
  1210. </Event>
  1211. <Event>
  1212. <Id>12437</Id>
  1213. <Message LcId="1033">The download of the Activate Project Cfg Data was refused because no Output Mapping Cfg Data were downloaded before</Message>
  1214. </Event>
  1215. <Event>
  1216. <Id>12438</Id>
  1217. <Message LcId="1033">The download of the Activate Project Cfg Data was refused because {0} mappings of the Output Mapping Cfg Data were missing</Message>
  1218. </Event>
  1219. <Event>
  1220. <Id>12439</Id>
  1221. <Message LcId="1033">The re-converted FB-Mapping-Code was not matching to the FB Cfg Data (FB: {0}, Code-Address: 0x{1,x}, Offset: 0x{2,x})</Message>
  1222. </Event>
  1223. <Event>
  1224. <Id>12440</Id>
  1225. <Message LcId="1033">a destination was mapped twice in the bit mapping code (page: 0x{0,x}, Code-Address: 0x{1,x})</Message>
  1226. </Event>
  1227. <Event>
  1228. <Id>12441</Id>
  1229. <Message LcId="1033">a destination was mapped twice in the byte mapping code (Page: 0x{0,x}, Code-Address: 0x{1,x})</Message>
  1230. </Event>
  1231. <Event>
  1232. <Id>12442</Id>
  1233. <Message LcId="1033">the number of groups was exceeded in the Vendor Data (actual value: {0}, minimum: {1}, maximum: {2})</Message>
  1234. </Event>
  1235. <Event>
  1236. <Id>12443</Id>
  1237. <Message LcId="1033">the number of FBs was exceeded in the Vendor Data (actual value: {0}, minimum: {1}, maximum: {2})</Message>
  1238. </Event>
  1239. <Event>
  1240. <Id>12444</Id>
  1241. <Message LcId="1033">the number of Connections was exceeded in the Vendor Data (actual value: {0}, minimum: {1}, maximum: {2})</Message>
  1242. </Event>
  1243. <Event>
  1244. <Id>12445</Id>
  1245. <Message LcId="1033">the number of Standard Inputs was exceeded in the Vendor Data (actual value: {0}, minimum: {1}, maximum: {2})</Message>
  1246. </Event>
  1247. <Event>
  1248. <Id>12446</Id>
  1249. <Message LcId="1033">the number of Standard Outputs was exceeded in the Vendor Data (actual value: {0}, minimum: {1}, maximum: {2})</Message>
  1250. </Event>
  1251. <Event>
  1252. <Id>12447</Id>
  1253. <Message LcId="1033">the FSoE message size was exceeded in the Vendor Data (actual value: {0}, minimum: {1}, maximum: {2})</Message>
  1254. </Event>
  1255. <Event>
  1256. <Id>12448</Id>
  1257. <Message LcId="1033">the FSoE safe user parameter size was exceeded in the Vendor Data (actual value: {0}, minimum: {1}, maximum: {2})</Message>
  1258. </Event>
  1259. <Event>
  1260. <Id>12449</Id>
  1261. <Message LcId="1033">the PROFIsafe message size was exceeded in the Vendor Data (actual value: {0}, minimum: {1}, maximum: {2})</Message>
  1262. </Event>
  1263. <Event>
  1264. <Id>12450</Id>
  1265. <Message LcId="1033">the EtherCAT Output size was exceeded in the Vendor Data (actual value: {0}, minimum: {1}, maximum: {2})</Message>
  1266. </Event>
  1267. <Event>
  1268. <Id>12451</Id>
  1269. <Message LcId="1033">the EtherCAT Input size was exceeded in the Vendor Data (actual value: {0}, minimum: {1}, maximum: {2})</Message>
  1270. </Event>
  1271. <Event>
  1272. <Id>12452</Id>
  1273. <Message LcId="1033">the EtherCAT Output size was exceeded in the project (calculated value: {0}, maximum value: {1})</Message>
  1274. </Event>
  1275. <Event>
  1276. <Id>12453</Id>
  1277. <Message LcId="1033">the EtherCAT Input size was exceeded in the project (calculated value: {0}, maximum value: {1})</Message>
  1278. </Event>
  1279. <Event>
  1280. <Id>12454</Id>
  1281. <Message LcId="1033">when re-converting the local FB mapping code (FB {0}) the analog destination address was below the minimum value (Code-Offset: 0x{1,x}, Data-Offset: 0x{2,x})</Message>
  1282. </Event>
  1283. <Event>
  1284. <Id>12455</Id>
  1285. <Message LcId="1033">when re-converting the local FB mapping code (FB {0}) the analog destination address was above the maximum value (Code-Offset: 0x{1,x}, Data-Offset: 0x{2,x})</Message>
  1286. </Event>
  1287. <Event>
  1288. <Id>12456</Id>
  1289. <Message LcId="1033">when re-converting the local FB mapping code (FB {0}) the destination address was not found (Code-Offset: 0x{1,x}, Data-Offset: 0x{2,x})</Message>
  1290. </Event>
  1291. <Event>
  1292. <Id>12457</Id>
  1293. <Message LcId="1033">when re-converting the local FB mapping code (FB {0}) the digital destination address was below the minimum value (Code-Offset: 0x{1,x}, Data-Offset: 0x{2,x})</Message>
  1294. </Event>
  1295. <Event>
  1296. <Id>12458</Id>
  1297. <Message LcId="1033">when re-converting the local FB mapping code (FB {0}) the digital destination address was above the maximum value (Code-Offset: 0x{1,x}, Data-Offset: 0x{2,x})</Message>
  1298. </Event>
  1299. <Event>
  1300. <Id>12459</Id>
  1301. <Message LcId="1033">when re-converting the local FB mapping code (FB {0}) the generated mapping data size was wrong (Code-Offset: 0x{1,x})</Message>
  1302. </Event>
  1303. <Event>
  1304. <Id>12460</Id>
  1305. <Message LcId="1033">the Project CRC in the Activate Project Cfg Data was wrong</Message>
  1306. </Event>
  1307. <Event>
  1308. <Id>12461</Id>
  1309. <Message LcId="1033">when re-converting the local FB mapping code the source bit address was wrong (FB: {0}, Code-Offset: 0x{1,x})</Message>
  1310. </Event>
  1311. <Event>
  1312. <Id>12462</Id>
  1313. <Message LcId="1033">when re-converting the local FB mapping code the source byte address was wrong (FB: {0}, Code-Offset: 0x{1,x})</Message>
  1314. </Event>
  1315. <Event>
  1316. <Id>12465</Id>
  1317. <Message LcId="1033">wrong subindex order when reading the input mapping cfg data, the expected subindex is {0}</Message>
  1318. </Event>
  1319. <Event>
  1320. <Id>12466</Id>
  1321. <Message LcId="1033">subindex exceeded when reading the cfg data</Message>
  1322. </Event>
  1323. <Event>
  1324. <Id>12467</Id>
  1325. <Message LcId="1033">the offset in the Replacement Values cfg data is wrong in the Group cfg data at word-offset 0x{0,x}</Message>
  1326. </Event>
  1327. <Event>
  1328. <Id>12468</Id>
  1329. <Message LcId="1033">the deactivation mode passivate is enabled and the number of connections is unequal 1 in the Group cfg data at word-offset 0x{0,x}</Message>
  1330. </Event>
  1331. <Event>
  1332. <Id>12469</Id>
  1333. <Message LcId="1033">the RUN-signal has to be active in the Group cfg data at word-offset 0x{0,x}</Message>
  1334. </Event>
  1335. <Event>
  1336. <Id>12470</Id>
  1337. <Message LcId="1033">in the Change FB-Parameter (FB {0}) the FB-type {1} is not supported</Message>
  1338. </Event>
  1339. <Event>
  1340. <Id>12471</Id>
  1341. <Message LcId="1033">the Subindex exceeds the number of connections ({0}) when writing the PROFIsafe F-Parameter</Message>
  1342. </Event>
  1343. <Event>
  1344. <Id>12472</Id>
  1345. <Message LcId="1033">the Connection-Type {0} does not support PROFIsafe F-Parameter</Message>
  1346. </Event>
  1347. <Event>
  1348. <Id>12473</Id>
  1349. <Message LcId="1033">the Subindex exceeds the number of connections ({0}) when writing the Store Slave Project CRC Parameter</Message>
  1350. </Event>
  1351. <Event>
  1352. <Id>12474</Id>
  1353. <Message LcId="1033">the Connection-Type {0} does not support Store Slave Project CRC Parameter</Message>
  1354. </Event>
  1355. <Event>
  1356. <Id>12475</Id>
  1357. <Message LcId="1033">if there are no Muting sensors behind the AOPD, the Backwards-Mode and optional Check of the OSSD inputs are not allowed</Message>
  1358. </Event>
  1359. <Event>
  1360. <Id>12476</Id>
  1361. <Message LcId="1033">when optional Check of the OSSD inputs is activated, the Sequential Inputs mode has to be activated too</Message>
  1362. </Event>
  1363. <Event>
  1364. <Id>12477</Id>
  1365. <Message LcId="1033">The number of Connections ({0}) is unequal the calculated number of connections over all groups ({1})</Message>
  1366. </Event>
  1367. <Event>
  1368. <Id>12478</Id>
  1369. <Message LcId="1033">The number of FBs ({0}) is unequal the calculated number of FBs over all groups ({1})</Message>
  1370. </Event>
  1371. <Event>
  1372. <Id>12479</Id>
  1373. <Message LcId="1033">The calculated local near process image size ({0}) exceeded the maximum near local process image size of {1}</Message>
  1374. </Event>
  1375. <Event>
  1376. <Id>12480</Id>
  1377. <Message LcId="1033">the EtherCAT Output size was exceeded in the connection cfg data at word offset 0x{0,x} (calculated value: {1}, maximum value: {2})</Message>
  1378. </Event>
  1379. <Event>
  1380. <Id>12481</Id>
  1381. <Message LcId="1033">the EtherCAT Input size was exceeded in the connection cfg data at word offset 0x{0,x} (calculated value: {1}, maximum value: {2})</Message>
  1382. </Event>
  1383. <Event>
  1384. <Id>12482</Id>
  1385. <Message LcId="1033">the reserved bits in the flags of the Vendor Data were set (actual value: 0x{0,x}, reserved flags: 0x{1,x})</Message>
  1386. </Event>
  1387. <Event>
  1388. <Id>12483</Id>
  1389. <Message LcId="1033">FB CAMMON: if the Setting Mode is enabled, at least one position marker has to be configured in the cfg data</Message>
  1390. </Event>
  1391. <Event>
  1392. <Id>12484</Id>
  1393. <Message LcId="1033">Connection Type is not supported at word-offset 0x{0,x} of the cfg data</Message>
  1394. </Event>
  1395. <Event>
  1396. <Id>12485</Id>
  1397. <Message LcId="1033">writing the PROFIsafe F-Parameter is not allowed in this logic state ({0}), the logic state has to be 1 (RUN)</Message>
  1398. </Event>
  1399. <Event>
  1400. <Id>12486</Id>
  1401. <Message LcId="1033">The ConnId 0x{0,x} is used at least twice</Message>
  1402. </Event>
  1403. <Event>
  1404. <Id>12487</Id>
  1405. <Message LcId="1033">The PROFIsafe Address 0x{0,x} is used at least twice</Message>
  1406. </Event>
  1407. <Event>
  1408. <Id>12488</Id>
  1409. <Message LcId="1033">The FSoE Address 0x{0,x} is used at least twice</Message>
  1410. </Event>
  1411. <Event>
  1412. <Id>12489</Id>
  1413. <Message LcId="1033">The TwinSAFE SC type {0} is used at least twice</Message>
  1414. </Event>
  1415. <Event>
  1416. <Id>12490</Id>
  1417. <Message LcId="1033">The TwinSAFE SC CRC 0x{0,x} is used at least twice</Message>
  1418. </Event>
  1419. <Event>
  1420. <Id>12491</Id>
  1421. <Message LcId="1033">The Connection Index {0} in a FB Connection Shutdown is used at least twice</Message>
  1422. </Event>
  1423. <Event>
  1424. <Id>12492</Id>
  1425. <Message LcId="1033">It is not allowed that the number of FBs and the number of Connections is zero inside the Group Cfg Data</Message>
  1426. </Event>
  1427. <Event>
  1428. <Id>12493</Id>
  1429. <Message LcId="1033">the storing of the Store Slave Project CRC Parameter is not supported in connection {0}</Message>
  1430. </Event>
  1431. <Event>
  1432. <Id>12494</Id>
  1433. <Message LcId="1033">The received size of Safety Input Messages ({0}) was too big, the maximum allowed value is {1}</Message>
  1434. </Event>
  1435. <Event>
  1436. <Id>12495</Id>
  1437. <Message LcId="1033">The received size of Safety Output Messages ({0}) was too big, the maximum allowed value is {1}</Message>
  1438. </Event>
  1439. <Event>
  1440. <Id>12496</Id>
  1441. <Message LcId="1033">The received size of PROFIsafe Input Messages ({0}) was too big, the maximum allowed value is {1}</Message>
  1442. </Event>
  1443. <Event>
  1444. <Id>12497</Id>
  1445. <Message LcId="1033">The received size of PROFIsafe Output Messages ({0}) was too big, the maximum allowed value is {1}</Message>
  1446. </Event>
  1447. <Event>
  1448. <Id>12498</Id>
  1449. <Message LcId="1033">The Restore Mode is supported on a TwinSAFE SC connection at word-offset 0x{0,x}</Message>
  1450. </Event>
  1451. <Event>
  1452. <Id>12499</Id>
  1453. <Message LcId="1033">The FB {0} (Connection Shutdown) is assigned to a non FSoE-connection</Message>
  1454. </Event>
  1455. <Event>
  1456. <Id>12500</Id>
  1457. <Message LcId="1033">The download of the TwinSAFE IO-Project failed because {0} FBs are configured (no FBs allowed)</Message>
  1458. </Event>
  1459. <Event>
  1460. <Id>12501</Id>
  1461. <Message LcId="1033">When the TwinSAFE-Address in the Project Cfg data should be used, it has to be unequal zero</Message>
  1462. </Event>
  1463. <Event>
  1464. <Id>12502</Id>
  1465. <Message LcId="1033">When the TwinSAFE-Address in the Project Cfg data should be used, the DIP-switch has to be zero (0x{0,x} found)</Message>
  1466. </Event>
  1467. <Event>
  1468. <Id>12503</Id>
  1469. <Message LcId="1033">Read aborted because of invalid code buffer offset (Calculated=0x{0,x}, Expected=0x{1,x})</Message>
  1470. </Event>
  1471. <Event>
  1472. <Id>12504</Id>
  1473. <Message LcId="1033">Invalid Safe User Parameter Offset at word offset 0x{0,x} (Calculated=0x{1,x}, Expected=0x{2,x})</Message>
  1474. </Event>
  1475. <Event>
  1476. <Id>12505</Id>
  1477. <Message LcId="1033">The Standard Inputs Size of zero is not allowed</Message>
  1478. </Event>
  1479. <Event>
  1480. <Id>12506</Id>
  1481. <Message LcId="1033">The download of the Replacement Values is not allowed after the download before (download state={0})</Message>
  1482. </Event>
  1483. <Event>
  1484. <Id>12507</Id>
  1485. <Message LcId="1033">The Info Data Map Cfg Data were downloaded in the wrong download state ({0})</Message>
  1486. </Event>
  1487. <Event>
  1488. <Id>12508</Id>
  1489. <Message LcId="1033">The offset for the safety-Timer has to be inside the safety Output Area from 0x{0,x} to 0x{1,x}</Message>
  1490. </Event>
  1491. <Event>
  1492. <Id>12509</Id>
  1493. <Message LcId="1033">The safety input size of connection {0} is zero offset, the Safety Inputs cannot be mapped at byte offset 0x{1,x} of Info Data Map Cfg Data</Message>
  1494. </Event>
  1495. <Event>
  1496. <Id>12510</Id>
  1497. <Message LcId="1033">The safety output size of connection {0} is zero, the Safety Outputs cannot be mapped at byte offset 0x{1,x} of Info Data Map Cfg Data</Message>
  1498. </Event>
  1499. <Event>
  1500. <Id>12511</Id>
  1501. <Message LcId="1033">No more safe user parameter expected at byte-offset 0x{0,x} of the Safe User Parameter Cfg Data</Message>
  1502. </Event>
  1503. <Event>
  1504. <Id>12512</Id>
  1505. <Message LcId="1033">The TwinSAFE Address 0 is not allowed in the Project Cfg Data</Message>
  1506. </Event>
  1507. <Event>
  1508. <Id>12513</Id>
  1509. <Message LcId="1033">The download of the TwinSAFE IO-Project failed because {0} Groups are configured (only 1 Group allowed)</Message>
  1510. </Event>
  1511. <Event>
  1512. <Id>12514</Id>
  1513. <Message LcId="1033">The download of the Delete Project Cfg Data is not allowed in this state ({0})</Message>
  1514. </Event>
  1515. <Event>
  1516. <Id>12515</Id>
  1517. <Message LcId="1033">The destination bit address (0x{0,x}, Bit {1}) already exists in the same mapping code</Message>
  1518. </Event>
  1519. <Event>
  1520. <Id>12516</Id>
  1521. <Message LcId="1033">Local Inputs cannot be mapped in the Info data because no local inputs are existing</Message>
  1522. </Event>
  1523. <Event>
  1524. <Id>12517</Id>
  1525. <Message LcId="1033">Local Outputs cannot be mapped in the Info data because no local outputs are existing</Message>
  1526. </Event>
  1527. <Event>
  1528. <Id>12518</Id>
  1529. <Message LcId="1033">The destination bit address (0x{0,x}, Bit {1}) already exists in the same mapping code</Message>
  1530. </Event>
  1531. <Event>
  1532. <Id>12519</Id>
  1533. <Message LcId="1033">the input mapping cfg data has to be read before the output mapping cfg data</Message>
  1534. </Event>
  1535. <Event>
  1536. <Id>12520</Id>
  1537. <Message LcId="1033">wrong subindex order when reading the mapping cfg data, the expected subindex is {0}</Message>
  1538. </Event>
  1539. <Event>
  1540. <Id>12521</Id>
  1541. <Message LcId="1033">when reading the input mapping cfg data, it has to be started with subindex 1</Message>
  1542. </Event>
  1543. <Event>
  1544. <Id>12522</Id>
  1545. <Message LcId="1033">invalid CRC when checking the Page {0} of the Safe Logic Cfg Data</Message>
  1546. </Event>
  1547. <Event>
  1548. <Id>12523</Id>
  1549. <Message LcId="1033">invalid CRC when checking the Page {0} of the Safe User Parameter Cfg Data</Message>
  1550. </Event>
  1551. <Event>
  1552. <Id>12524</Id>
  1553. <Message LcId="1033">invalid CRC when checking the Page {0} of the Replacement values Cfg Data</Message>
  1554. </Event>
  1555. <Event>
  1556. <Id>12544</Id>
  1557. <Message LcId="1033">No groups defined when trying to activate or deactivate groups</Message>
  1558. </Event>
  1559. <Event>
  1560. <Id>12545</Id>
  1561. <Message LcId="1033">The reserved bits are set in value {0} at offset {1} when trying to activate or deactivate groups</Message>
  1562. </Event>
  1563. <Event>
  1564. <Id>12546</Id>
  1565. <Message LcId="1033">The operation mode at offset {0} is not supported when trying to activate or deactivate groups</Message>
  1566. </Event>
  1567. <Event>
  1568. <Id>12547</Id>
  1569. <Message LcId="1033">The deactivation of groups is not enabled for any group so no replacement values should be downloaded</Message>
  1570. </Event>
  1571. <Event>
  1572. <Id>12548</Id>
  1573. <Message LcId="1033">The maximum number ({0}) of Cfg Data pages was exceeded in the Replacement Values Cfg Data</Message>
  1574. </Event>
  1575. <Event>
  1576. <Id>12549</Id>
  1577. <Message LcId="1033">Invalid FB output size size at offset {0} of the Replacement Values Cfg Data</Message>
  1578. </Event>
  1579. <Event>
  1580. <Id>12550</Id>
  1581. <Message LcId="1033">Unexpected groupindex in the Replacement values Cfg Data at offset 0x{0,x}</Message>
  1582. </Event>
  1583. <Event>
  1584. <Id>12551</Id>
  1585. <Message LcId="1033">The download of the Activate Project Cfg Data was refused because {0} bytes of the Replacement Values Cfg Data were missing</Message>
  1586. </Event>
  1587. <Event>
  1588. <Id>12552</Id>
  1589. <Message LcId="1033">To activate the Group {0} the user has to logged in with access rights Bit 0-15 unequal 0 that the Safe Logic Program will be stopped when logging in</Message>
  1590. </Event>
  1591. <Event>
  1592. <Id>12553</Id>
  1593. <Message LcId="1033">No more definitions of individual replace values for analog FB Outputs in case of Group State unequal RUN are expected at offset {0}</Message>
  1594. </Event>
  1595. <Event>
  1596. <Id>12554</Id>
  1597. <Message LcId="1033">The offset in the definitions of individual replace values for analog FB Outputs in case of Group State unequal RUN was wrong at offset {0}</Message>
  1598. </Event>
  1599. <Event>
  1600. <Id>12555</Id>
  1601. <Message LcId="1033">The source process image offset of the Cyclic FRAM Data is outside the FB analog input area at offset {0}</Message>
  1602. </Event>
  1603. <Event>
  1604. <Id>12556</Id>
  1605. <Message LcId="1033">The source process image offset of the Cyclic FRAM Data has to even at offset {0}</Message>
  1606. </Event>
  1607. <Event>
  1608. <Id>12557</Id>
  1609. <Message LcId="1033">The size of the Cyclic FRAM Data was exceeding at offset {0}</Message>
  1610. </Event>
  1611. <Event>
  1612. <Id>12558</Id>
  1613. <Message LcId="1033">The received size of the Cyclic FRAM Data at word offset 24 of the Safe Logic Cfg Data ({0}) is unequal the calculated value of {1}</Message>
  1614. </Event>
  1615. <Event>
  1616. <Id>12559</Id>
  1617. <Message LcId="1033">The size of the Cyclic FRAM CfgData in the GroupCfgData was not dividable by 4 at offset {0}</Message>
  1618. </Event>
  1619. <Event>
  1620. <Id>12560</Id>
  1621. <Message LcId="1033">The offset of the Cyclic FRAM Data in the GroupCfgData was wrong at offset {0}</Message>
  1622. </Event>
  1623. <Event>
  1624. <Id>12561</Id>
  1625. <Message LcId="1033">The value of {0} at offset {1} is not allowed when trying to activate or deactivate groups</Message>
  1626. </Event>
  1627. <Event>
  1628. <Id>12562</Id>
  1629. <Message LcId="1033">The activating or deactivating of groups is not allowed in PREOP</Message>
  1630. </Event>
  1631. <Event>
  1632. <Id>12563</Id>
  1633. <Message LcId="1033">FB CAMMON (Word-Offset 0x{0,x} of the CfgData): The TDC2UpperLimit ({1}) is lower or equal than the maximum position jitter ({2})</Message>
  1634. </Event>
  1635. <Event>
  1636. <Id>12564</Id>
  1637. <Message LcId="1033">FB CAMMON (Word-Offset 0x{0,x} of the CfgData): The TDCUpperLimit ({1}) is lower or equal than the maximum position jitter ({2})</Message>
  1638. </Event>
  1639. <Event>
  1640. <Id>12565</Id>
  1641. <Message LcId="1033">FB CAMMON (Word-Offset 0x{0,x} of the CfgData): The value of TDCLowerLimit (plus maximum position jitter) ({1}) is bigger or equal the configured position of 360° ({2})</Message>
  1642. </Event>
  1643. <Event>
  1644. <Id>12566</Id>
  1645. <Message LcId="1033">FB CAMMON (Word-Offset 0x{0,x} of the CfgData): The value of BDCUpperLimit (plus twice the maximum position jitter) ({1}) is bigger or equal the value of TDCLowerLimit ({2})</Message>
  1646. </Event>
  1647. <Event>
  1648. <Id>12567</Id>
  1649. <Message LcId="1033">FB CAMMON (Word-Offset 0x{0,x} of the CfgData): The value of BDCUpperLimit ({1}) is smaller or equal the configured value of 180° (plus maximum position jitter) ({2})</Message>
  1650. </Event>
  1651. <Event>
  1652. <Id>12568</Id>
  1653. <Message LcId="1033">FB CAMMON (Word-Offset 0x{0,x} of the CfgData): The value of BDCLowerLimit (plus maximum position jitter) ({1}) is greater or equal the configured value of 180° ({2})</Message>
  1654. </Event>
  1655. <Event>
  1656. <Id>12569</Id>
  1657. <Message LcId="1033">FB CAMMON (Word-Offset 0x{0,x} of the CfgData): The value of OverrunMax (plus twice the maximum position jitter) ({1}) is bigger or equal the value of BDCLowerLimit ({2})</Message>
  1658. </Event>
  1659. <Event>
  1660. <Id>12570</Id>
  1661. <Message LcId="1033">FB CAMMON (Word-Offset 0x{0,x} of the CfgData): The value of TDCUpperLimit (plus twice the maximum position jitter) ({1}) is bigger or equal the value of OverrunMax ({2})</Message>
  1662. </Event>
  1663. <Event>
  1664. <Id>12571</Id>
  1665. <Message LcId="1033">FB CAMMON (Word-Offset 0x{0,x} of the CfgData): The value of TDC1UpperLimit (plus the maximum position jitter) ({1}) is bigger or equal the configured position of 360° ({2})</Message>
  1666. </Event>
  1667. <Event>
  1668. <Id>12572</Id>
  1669. <Message LcId="1033">FB CAMMON (Word-Offset 0x{0,x} of the CfgData): The value of TDC1LowerLimit (plus twice the maximum position jitter) ({1}) is bigger or equal the value of TDC1UpperLimit (5d)</Message>
  1670. </Event>
  1671. <Event>
  1672. <Id>12573</Id>
  1673. <Message LcId="1033">FB CAMMON (Word-Offset 0x{0,x} of the CfgData): The value of TDC2LowerLimit (plus twice the maximum position jitter) ({1}) is bigger or equal the value of BDCLowerLimit ({2})</Message>
  1674. </Event>
  1675. <Event>
  1676. <Id>12574</Id>
  1677. <Message LcId="1033">FB CAMMON (Word-Offset 0x{0,x} of the CfgData): The value of TDC2UpperLimit (plus twice the maximum position jitter) ({1}) is bigger or equal the value of TDC2LowerLimit ({2})</Message>
  1678. </Event>
  1679. <Event>
  1680. <Id>12575</Id>
  1681. <Message LcId="1033">The maximum size of the Replacement Values was exceeded at Word-Offset 0x{0,x} of the Group Cfg Data</Message>
  1682. </Event>
  1683. <Event>
  1684. <Id>12576</Id>
  1685. <Message LcId="1033">If no deactivation mode is enabled the offset of the replacement values shall be zero at Word-Offset 0x{0,x} of the Group Cfg Data</Message>
  1686. </Event>
  1687. <Event>
  1688. <Id>12577</Id>
  1689. <Message LcId="1033">No more replacement values expected at byte-offset 0x{0,x} of the Replacement Values Cfg Data</Message>
  1690. </Event>
  1691. <Event>
  1692. <Id>12578</Id>
  1693. <Message LcId="1033">The Download of the Project CRC is not allowed in PREOP</Message>
  1694. </Event>
  1695. <Event>
  1696. <Id>12800</Id>
  1697. <Message LcId="1033">The PROFIsafe-protocol is not supported on this device</Message>
  1698. </Event>
  1699. <Event>
  1700. <Id>12801</Id>
  1701. <Message LcId="1033">The F_ParVersion in the F_Prm_Flag2 of the F-Parameter at Word-Offset 0x{0,x} is unequal 1 (PROFIsafe V2)</Message>
  1702. </Event>
  1703. <Event>
  1704. <Id>12802</Id>
  1705. <Message LcId="1033">The F_CRC1 of the F-Parameter at Word-Offset 0x{0,x} is wrong</Message>
  1706. </Event>
  1707. <Event>
  1708. <Id>12803</Id>
  1709. <Message LcId="1033">The F_CRC_Length in the F_Prm_Flag1 of the F-Parameter is wrong at Word-Offset 0x{0,x}, the expected value is 0 (3 Bytes CRC2)</Message>
  1710. </Event>
  1711. <Event>
  1712. <Id>12806</Id>
  1713. <Message LcId="1033">The I-Parameter CRC in the F-Parameter is wrong at Word-Offset 0x{0,x}</Message>
  1714. </Event>
  1715. <Event>
  1716. <Id>12807</Id>
  1717. <Message LcId="1033">The F_Block_ID in the F_Prm_Flag2 of the F-Parameter is wrong at Word-Offset 0x{0,x}, the expected value is 0 (No F_iPar_CRC, no F_WD_Time 2) or 1 (F_iPar_CRC, no F_WD_Time 2)</Message>
  1718. </Event>
  1719. <Event>
  1720. <Id>12808</Id>
  1721. <Message LcId="1033">The F_Source_Address in the F-Parameter at Word-Offset 0x{0,x} is outside the allowed area of 1-0xFFFE</Message>
  1722. </Event>
  1723. <Event>
  1724. <Id>12809</Id>
  1725. <Message LcId="1033">The F_Destination_Address in the F-Parameter at Word-Offset 0x{0,x} is outside the allowed area of 1-0xFFFE</Message>
  1726. </Event>
  1727. <Event>
  1728. <Id>12810</Id>
  1729. <Message LcId="1033">The F_WD_Time in the F-parameter at Word-Offset 0x{0,x} is outside the allowed range from 2-60000</Message>
  1730. </Event>
  1731. <Event>
  1732. <Id>12811</Id>
  1733. <Message LcId="1033">The F_Destination_Address in the F-Parameter at Word-Offset 0x{0,x} is wrong, the expected value is {1}</Message>
  1734. </Event>
  1735. <Event>
  1736. <Id>13056</Id>
  1737. <Message LcId="1033">The State OPERATIONAL was left in Restore Mode</Message>
  1738. </Event>
  1739. <Event>
  1740. <Id>13057</Id>
  1741. <Message LcId="1033">Only {0} CRCs were matching in Restore Mode</Message>
  1742. </Event>
  1743. <Event>
  1744. <Id>13058</Id>
  1745. <Message LcId="1033">The CRC of the Activate Project Cfg Data in Restore Mode does not match, the expected value was 0x{0,x}</Message>
  1746. </Event>
  1747. <Event>
  1748. <Id>13059</Id>
  1749. <Message LcId="1033">No RestoreMode Slaves configured when trying to start the Restore Mode</Message>
  1750. </Event>
  1751. <Event>
  1752. <Id>13060</Id>
  1753. <Message LcId="1033">The CRC of the User List Cfg Data was not matching in Restore Mode, the expected value was 0x{0,x}</Message>
  1754. </Event>
  1755. <Event>
  1756. <Id>13061</Id>
  1757. <Message LcId="1033">The download of the User List Cfg Data is not activated in Restore Mode</Message>
  1758. </Event>
  1759. <Event>
  1760. <Id>13062</Id>
  1761. <Message LcId="1033">The download of the User List Cfg Data in Restore-Mode is not allowed in the state {0}</Message>
  1762. </Event>
  1763. <Event>
  1764. <Id>13063</Id>
  1765. <Message LcId="1033">The activation of the TwinSAFE Restore Project is not allowed in the state {0}</Message>
  1766. </Event>
  1767. <Event>
  1768. <Id>13064</Id>
  1769. <Message LcId="1033">The Restore Mode is not supported in EtherCAT state 0x{0,x}</Message>
  1770. </Event>
  1771. <Event>
  1772. <Id>13072</Id>
  1773. <Message LcId="1033">The FSoE-Slave on the {0}. connection is in Restore-Mode</Message>
  1774. </Event>
  1775. <Event>
  1776. <Id>13073</Id>
  1777. <Message LcId="1033">The FSoE-Master on the {0}. connection is in Restore-Mode</Message>
  1778. </Event>
  1779. <Event>
  1780. <Id>13312</Id>
  1781. <Message LcId="1033">The {0}. group has no more errors</Message>
  1782. </Event>
  1783. <Event>
  1784. <Id>13313</Id>
  1785. <Message LcId="1033">The Analog Input at word offset {0} of the analog input process image has expired maximum allowed deviation to the last stored value, received value: {1}, last stored value: {2}</Message>
  1786. </Event>
  1787. <Event>
  1788. <Id>13314</Id>
  1789. <Message LcId="1033">The Wait-Com-Error-Timeout has not been expired when the group {0} should be deactivated in passivate mode</Message>
  1790. </Event>
  1791. <Event>
  1792. <Id>13315</Id>
  1793. <Message LcId="1033">A module fault happened in group {0}</Message>
  1794. </Event>
  1795. <Event>
  1796. <Id>13316</Id>
  1797. <Message LcId="1033">The assigned connection reported an error when the group {0} was deactivated in passivate mode</Message>
  1798. </Event>
  1799. <Event>
  1800. <Id>13317</Id>
  1801. <Message LcId="1033">The connection has been successfully restarted when the group {0} was deactivated in passivate mode</Message>
  1802. </Event>
  1803. <Event>
  1804. <Id>13328</Id>
  1805. <Message LcId="1033">All groups will enter the ERROR-state because the safe logic program has been restarted</Message>
  1806. </Event>
  1807. <Event>
  1808. <Id>13329</Id>
  1809. <Message LcId="1033">All groups will enter the ERROR-state because the CRC of the Change Group Activation Data was wrong</Message>
  1810. </Event>
  1811. <Event>
  1812. <Id>13330</Id>
  1813. <Message LcId="1033">All groups will enter the ERROR-state because the CRC of the Change FB Parameter Data was wrong</Message>
  1814. </Event>
  1815. <Event>
  1816. <Id>13331</Id>
  1817. <Message LcId="1033">All groups will enter the ERROR-state because the CRC of the Project CRC Data was wrong</Message>
  1818. </Event>
  1819. <Event>
  1820. <Id>13332</Id>
  1821. <Message LcId="1033">All groups will enter the ERROR-state because the CRC of the Cyclic FRAM Data was wrong</Message>
  1822. </Event>
  1823. <Event>
  1824. <Id>13333</Id>
  1825. <Message LcId="1033">The TwinSAFE Logic Program was not loaded on C1 because of an inconsistency</Message>
  1826. </Event>
  1827. <Event>
  1828. <Id>13334</Id>
  1829. <Message LcId="1033">The TwinSAFE Logic Program was not loaded on C2 because of an inconsistency</Message>
  1830. </Event>
  1831. <Event>
  1832. <Id>13335</Id>
  1833. <Message LcId="1033">All groups will enter the ERROR-state because the initialization of Cyclic FRAM Data was wrong</Message>
  1834. </Event>
  1835. <Event>
  1836. <Id>13336</Id>
  1837. <Message LcId="1033">Safe User Parameter from FRAM are not correct</Message>
  1838. </Event>
  1839. <Event>
  1840. <Id>13344</Id>
  1841. <Message LcId="1033">No more EtherCAT size error (EtherCAT Output Size={0}, EtherCAT Input Size={1})</Message>
  1842. </Event>
  1843. <Event>
  1844. <Id>13345</Id>
  1845. <Message LcId="1033">The EtherCAT Output Data sizes of the Safety Logic Program ({0}) and the EtherCAT Configuration ({1}) are unequal</Message>
  1846. </Event>
  1847. <Event>
  1848. <Id>13346</Id>
  1849. <Message LcId="1033">The EtherCAT Input Data sizes of the Safety Logic Program ({0}) and the EtherCAT Configuration ({1}) are unequal</Message>
  1850. </Event>
  1851. <Event>
  1852. <Id>13347</Id>
  1853. <Message LcId="1033">The EtherCAT Output Data sizes for PROFIsafe of the Safety Logic Program ({0}) and the EtherCAT Configuration ({1}) are unequal</Message>
  1854. </Event>
  1855. <Event>
  1856. <Id>13348</Id>
  1857. <Message LcId="1033">The EtherCAT Input Data sizes for PROFIsafe of the Safety Logic Program ({0}) and the EtherCAT Configuration ({1}) are unequal</Message>
  1858. </Event>
  1859. <Event>
  1860. <Id>13349</Id>
  1861. <Message LcId="1033">The needed EtherCAT Process data buffer size ({0}) exceeded the maximum available size of {1}</Message>
  1862. </Event>
  1863. <Event>
  1864. <Id>13569</Id>
  1865. <Message LcId="1033">On the {0}. connection the changeable FSoE Address of {1} already exists</Message>
  1866. </Event>
  1867. <Event>
  1868. <Id>13570</Id>
  1869. <Message LcId="1033">On the {0}. connection the changeable FSoE Address is zero</Message>
  1870. </Event>
  1871. <Event>
  1872. <Id>14336</Id>
  1873. <Message LcId="1033">FB {0} (ESTOP): An EDM-fault (0x{1,x}) was detected in state SAFE</Message>
  1874. </Event>
  1875. <Event>
  1876. <Id>14338</Id>
  1877. <Message LcId="1033">FB {0} (ESTOP): An EDM-fault (0x{1,x}) was detected in state RESET</Message>
  1878. </Event>
  1879. <Event>
  1880. <Id>14339</Id>
  1881. <Message LcId="1033">FB {0} (ESTOP): An EDM-fault (0x{1,x}) was detected in state START</Message>
  1882. </Event>
  1883. <Event>
  1884. <Id>14340</Id>
  1885. <Message LcId="1033">FB {0} (ESTOP): An DiscTime-Fault (0x{1,x}) was detected in state SAFE, the actual EStopIn-values are 0x{2,x}</Message>
  1886. </Event>
  1887. <Event>
  1888. <Id>14342</Id>
  1889. <Message LcId="1033">FB {0} (ESTOP): An DiscTime-Fault (0x{1,x}) was detected in state RESET, the actual EStopIn-values are 0x{2,x}</Message>
  1890. </Event>
  1891. <Event>
  1892. <Id>14343</Id>
  1893. <Message LcId="1033">FB {0} (ESTOP): An DiscTime-Fault (0x{1,x}) was detected in state START, the actual EStopIn-values are 0x{2,x}</Message>
  1894. </Event>
  1895. <Event>
  1896. <Id>14345</Id>
  1897. <Message LcId="1033">FB {0} (ESTOP): An DiscTime-Fault (0x{1,x}) was detected in state DELAYOUT, the actual EStopIn-values are 0x{2,x}</Message>
  1898. </Event>
  1899. <Event>
  1900. <Id>14351</Id>
  1901. <Message LcId="1033">FB {0} (ESTOP): At least one activated EDM-Input was not reset in RUN when the EDM Reset time had been expired (Diag-Code=0x{1,x})</Message>
  1902. </Event>
  1903. <Event>
  1904. <Id>14352</Id>
  1905. <Message LcId="1033">FB {0} (MON): An EDM-fault (0x{1,x}) was detected in state SAFE</Message>
  1906. </Event>
  1907. <Event>
  1908. <Id>14354</Id>
  1909. <Message LcId="1033">FB {0} (MON): An EDM-fault (0x{1,x}) was detected in state RESET</Message>
  1910. </Event>
  1911. <Event>
  1912. <Id>14355</Id>
  1913. <Message LcId="1033">FB {0} (MON): An EDM-fault (0x{1,x}) was detected in state START</Message>
  1914. </Event>
  1915. <Event>
  1916. <Id>14356</Id>
  1917. <Message LcId="1033">FB {0} (MON): An DiscTime-Fault (0x{1,x}) was detected in state SAFE, the actual MonIn/Secure-values are 0x{2,x}</Message>
  1918. </Event>
  1919. <Event>
  1920. <Id>14358</Id>
  1921. <Message LcId="1033">FB {0} (MON): An DiscTime-Fault (0x{1,x}) was detected in state RESET, the actual MonIn/Secure-values are 0x{2,x}</Message>
  1922. </Event>
  1923. <Event>
  1924. <Id>14359</Id>
  1925. <Message LcId="1033">FB {0} (MON): An DiscTime-Fault (0x{1,x}) was detected in state START, the actual MonIn/Secure-values are 0x{2,x}</Message>
  1926. </Event>
  1927. <Event>
  1928. <Id>14360</Id>
  1929. <Message LcId="1033">FB {0} (MON): An DiscTime-Fault (0x{1,x}) was detected in state RUN, the actual MonIn/Secure-values are 0x{2,x}</Message>
  1930. </Event>
  1931. <Event>
  1932. <Id>14361</Id>
  1933. <Message LcId="1033">FB {0} (MON): An DiscTime-Fault (0x{1,x}) was detected in state DELAYOUT, the actual MonIn/Secure-values are 0x{2,x}</Message>
  1934. </Event>
  1935. <Event>
  1936. <Id>14362</Id>
  1937. <Message LcId="1033">FB {0} (MON): An DiscTime-Fault (0x{1,x}) was detected in state FUNCTEST, the actual MonIn/Secure-values are 0x{2,x}</Message>
  1938. </Event>
  1939. <Event>
  1940. <Id>14367</Id>
  1941. <Message LcId="1033">FB {0} (MON): At least one activated EDM-Input was not reset in RUN when the EDM Reset time had been expired (Diag-Code=0x{1,x})</Message>
  1942. </Event>
  1943. <Event>
  1944. <Id>14368</Id>
  1945. <Message LcId="1033">FB {0} (TWOHAND): A Disc-Group-fault (0x{1,x}) was detected in state 1BUTTON, the actual TwoHandIn-values are 0x{2,x}</Message>
  1946. </Event>
  1947. <Event>
  1948. <Id>14369</Id>
  1949. <Message LcId="1033">FB {0} (TWOHAND): A Disc-Group-fault (0x{1,x}) was detected in state 2BUTTON, the actual TwoHandIn-values are 0x{2,x}</Message>
  1950. </Event>
  1951. <Event>
  1952. <Id>14371</Id>
  1953. <Message LcId="1033">FB {0} (TWOHAND): An DiscTime-Fault (0x{1,x}) was detected in state SAFE, the actual TwoHandIn-values are 0x{2,x}</Message>
  1954. </Event>
  1955. <Event>
  1956. <Id>14373</Id>
  1957. <Message LcId="1033">FB {0} (TWOHAND): An DiscTime-Fault (0x{1,x}) was detected in state RESET, the actual TwoHandIn-values are 0x{2,x}</Message>
  1958. </Event>
  1959. <Event>
  1960. <Id>14379</Id>
  1961. <Message LcId="1033">FB {0} (TWOHAND): An DiscTime-Fault (0x{1,x}) was detected in state 1BUTTON, the actual TwoHandIn-values are 0x{2,x}</Message>
  1962. </Event>
  1963. <Event>
  1964. <Id>14380</Id>
  1965. <Message LcId="1033">FB {0} (TWOHAND): An DiscTime-Fault (0x{1,x}) was detected in state 2BUTTON, the actual TwoHandIn-values are 0x{2,x}</Message>
  1966. </Event>
  1967. <Event>
  1968. <Id>14381</Id>
  1969. <Message LcId="1033">FB {0} (TWOHAND): An DiscTime-Fault (0x{1,x}) was detected in state RELEASE, the actual TwoHandIn-values are 0x{2,x}</Message>
  1970. </Event>
  1971. <Event>
  1972. <Id>14384</Id>
  1973. <Message LcId="1033">FB {0} (OPMODE): An DiscTime-Fault (0x{1,x}) was detected, the actual OpIn-values are 0x{2,x}</Message>
  1974. </Event>
  1975. <Event>
  1976. <Id>14385</Id>
  1977. <Message LcId="1033">FB {0} (OPMODE): An Input-Fault was detected in state RESET, the actual OpIn-values are 0x{1,x}</Message>
  1978. </Event>
  1979. <Event>
  1980. <Id>14400</Id>
  1981. <Message LcId="1033">FB {0} (EDM): The SwitchOn-Time had been expired</Message>
  1982. </Event>
  1983. <Event>
  1984. <Id>14401</Id>
  1985. <Message LcId="1033">FB {0} (EDM): The SwitchOff-Time had been expired</Message>
  1986. </Event>
  1987. <Event>
  1988. <Id>14419</Id>
  1989. <Message LcId="1033">FB {0} (CS): An DiscTime-Fault (0x{1,x}) was detected in state SAFE, the actual Deactivate-values are 0x{2,x}</Message>
  1990. </Event>
  1991. <Event>
  1992. <Id>14421</Id>
  1993. <Message LcId="1033">FB {0} (CS): An DiscTime-Fault (0x{1,x}) was detected in state RESET, the actual Deactivate-values are 0x{2,x}</Message>
  1994. </Event>
  1995. <Event>
  1996. <Id>14465</Id>
  1997. <Message LcId="1033">FB {0} (MUTING): An DiscTime-Fault (0x{1,x}) was detected in state RUN, the actual MuteIn/OssdIn-values are 0x{2,x}</Message>
  1998. </Event>
  1999. <Event>
  2000. <Id>14467</Id>
  2001. <Message LcId="1033">FB {0} (MUTING): An DiscTime-Fault (0x{1,x}) was detected in state SAFE, the actual MuteIn/OssdIn-values are 0x{2,x}</Message>
  2002. </Event>
  2003. <Event>
  2004. <Id>14469</Id>
  2005. <Message LcId="1033">FB {0} (MUTING): An DiscTime-Fault (0x{1,x}) was detected in state RESET, the actual MuteIn/OssdIn-values are 0x{2,x}</Message>
  2006. </Event>
  2007. <Event>
  2008. <Id>14472</Id>
  2009. <Message LcId="1033">FB {0} (MUTING): An DiscTime-Fault (0x{1,x}) was detected in state DELAYOUT, the actual MuteIn/OssdIn-values are 0x{2,x}</Message>
  2010. </Event>
  2011. <Event>
  2012. <Id>14473</Id>
  2013. <Message LcId="1033">FB {0} (MUTING): An DiscTime-Fault (0x{1,x}) was detected in state MUTING1, the actual MuteIn/OssdIn-values are 0x{2,x}</Message>
  2014. </Event>
  2015. <Event>
  2016. <Id>14474</Id>
  2017. <Message LcId="1033">FB {0} (MUTING): An DiscTime-Fault (0x{1,x}) was detected in state MUTING2, the actual MuteIn/OssdIn-values are 0x{2,x}</Message>
  2018. </Event>
  2019. <Event>
  2020. <Id>14475</Id>
  2021. <Message LcId="1033">FB {0} (MUTING): An DiscTime-Fault (0x{1,x}) was detected in state MUTING3, the actual MuteIn/OssdIn-values are 0x{2,x}</Message>
  2022. </Event>
  2023. <Event>
  2024. <Id>14476</Id>
  2025. <Message LcId="1033">FB {0} (MUTING): An DiscTime-Fault (0x{1,x}) was detected in state MUTING4, the actual MuteIn/OssdIn-values are 0x{2,x}</Message>
  2026. </Event>
  2027. <Event>
  2028. <Id>14477</Id>
  2029. <Message LcId="1033">FB {0} (MUTING): An DiscTime-Fault (0x{1,x}) was detected in state MUTING5, the actual MuteIn/OssdIn-values are 0x{2,x}</Message>
  2030. </Event>
  2031. <Event>
  2032. <Id>14478</Id>
  2033. <Message LcId="1033">FB {0} (MUTING): An DiscTime-Fault (0x{1,x}) was detected in state MUTING6, the actual MuteIn/OssdIn-values are 0x{2,x}</Message>
  2034. </Event>
  2035. <Event>
  2036. <Id>14479</Id>
  2037. <Message LcId="1033">FB {0} (MUTING): An DiscTime-Fault (0x{1,x}) was detected in state MUTING7, the actual MuteIn/OssdIn-values are 0x{2,x}</Message>
  2038. </Event>
  2039. <Event>
  2040. <Id>14480</Id>
  2041. <Message LcId="1033">FB {0} (MUTING): An DiscTime-Fault (0x{1,x}) was detected in state MUTING8, the actual MuteIn/OssdIn-values are 0x{2,x}</Message>
  2042. </Event>
  2043. <Event>
  2044. <Id>14481</Id>
  2045. <Message LcId="1033">FB {0} (MUTING): An DiscTime-Fault (0x{1,x}) was detected in state MUTING9, the actual MuteIn/OssdIn-values are 0x{2,x}</Message>
  2046. </Event>
  2047. <Event>
  2048. <Id>14482</Id>
  2049. <Message LcId="1033">FB {0} (MUTING): State RUN, Sequential Inputs=TRUE: MutingEnable is set and the MuteIn-signals are invalid, the actual MuteIn/OssdIn-values are 0x{1,x}</Message>
  2050. </Event>
  2051. <Event>
  2052. <Id>14483</Id>
  2053. <Message LcId="1033">FB {0} (MUTING): State RUN, Sequential Inputs=FALSE: MutingEnable is set and the MuteIn-signals are invalid, the actual MuteIn/OssdIn-values are 0x{1,x}</Message>
  2054. </Event>
  2055. <Event>
  2056. <Id>14484</Id>
  2057. <Message LcId="1033">FB {0} (MUTING): State MUTING1, MutingEnable is set and the OssdIn-signals are invalid, the actual MuteIn/OssdIn-values are 0x{1,x}</Message>
  2058. </Event>
  2059. <Event>
  2060. <Id>14485</Id>
  2061. <Message LcId="1033">FB {0} (MUTING): State MUTING1, MutingEnable is set and the MuteIn-signals are invalid, the actual MuteIn/OssdIn-values are 0x{1,x}</Message>
  2062. </Event>
  2063. <Event>
  2064. <Id>14486</Id>
  2065. <Message LcId="1033">FB {0} (MUTING): State MUTING2, MutingEnable is set and the MuteIn-signals before the AOPD are invalid, the actual MuteIn/OssdIn-values are 0x{1,x}</Message>
  2066. </Event>
  2067. <Event>
  2068. <Id>14487</Id>
  2069. <Message LcId="1033">FB {0} (MUTING): State MUTING2, MutingEnable is set and the MuteIn-signals after the AOPD are invalid, the actual MuteIn/OssdIn-values are 0x{1,x}</Message>
  2070. </Event>
  2071. <Event>
  2072. <Id>14488</Id>
  2073. <Message LcId="1033">FB {0} (MUTING): State MUTING3, MutingEnable is set and the OssdIn-signals are invalid, the actual MuteIn/OssdIn-values are 0x{1,x}</Message>
  2074. </Event>
  2075. <Event>
  2076. <Id>14489</Id>
  2077. <Message LcId="1033">FB {0} (MUTING): State MUTING3, Sequential Inputs=TRUE: MutingEnable is set and the MuteIn-signals are invalid, the actual MuteIn/OssdIn-values are 0x{1,x}</Message>
  2078. </Event>
  2079. <Event>
  2080. <Id>14490</Id>
  2081. <Message LcId="1033">FB {0} (MUTING): State MUTING3, Sequential Inputs=FALSE: MutingEnable is set and the MuteIn-signals are invalid, the actual MuteIn/OssdIn-values are 0x{1,x}</Message>
  2082. </Event>
  2083. <Event>
  2084. <Id>14491</Id>
  2085. <Message LcId="1033">FB {0} (MUTING): State MUTING4, MutingEnable is set and the OssdIn-signals are invalid, the actual MuteIn/OssdIn-values are 0x{1,x}</Message>
  2086. </Event>
  2087. <Event>
  2088. <Id>14492</Id>
  2089. <Message LcId="1033">FB {0} (MUTING): State MUTING4, MutingEnable is set and the MuteIn-signals are invalid, the actual MuteIn/OssdIn-values are 0x{1,x}</Message>
  2090. </Event>
  2091. <Event>
  2092. <Id>14493</Id>
  2093. <Message LcId="1033">FB {0} (MUTING): State MUTING5, MutingEnable is set and the OssdIn-signals are invalid, the actual MuteIn/OssdIn-values are 0x{1,x}</Message>
  2094. </Event>
  2095. <Event>
  2096. <Id>14494</Id>
  2097. <Message LcId="1033">FB {0} (MUTING): State MUTING5, Sequential Inputs=TRUE: MutingEnable is set and the MuteIn-signals are invalid, the actual MuteIn/OssdIn-values are 0x{1,x}</Message>
  2098. </Event>
  2099. <Event>
  2100. <Id>14495</Id>
  2101. <Message LcId="1033">FB {0} (MUTING): State MUTING5, Sequential Inputs=FALSE: MutingEnable is set and the MuteIn-signals are invalid, the actual MuteIn/OssdIn-values are 0x{1,x}</Message>
  2102. </Event>
  2103. <Event>
  2104. <Id>14496</Id>
  2105. <Message LcId="1033">FB {0} (MUTING): State MUTING6, MutingEnable is set and the OssdIn-signals are invalid, the actual MuteIn/OssdIn-values are 0x{1,x}</Message>
  2106. </Event>
  2107. <Event>
  2108. <Id>14497</Id>
  2109. <Message LcId="1033">FB {0} (MUTING): State MUTING6, MutingEnable is set and the MuteIn-signals are invalid, the actual MuteIn/OssdIn-values are 0x{1,x}</Message>
  2110. </Event>
  2111. <Event>
  2112. <Id>14498</Id>
  2113. <Message LcId="1033">FB {0} (MUTING): State MUTING7, MutingEnable is set and the MuteIn-signals before the AOPD are invalid, the actual MuteIn/OssdIn-values are 0x{1,x}</Message>
  2114. </Event>
  2115. <Event>
  2116. <Id>14499</Id>
  2117. <Message LcId="1033">FB {0} (MUTING): State MUTING7, MutingEnable is set and the MuteIn-signals after the AOPD are invalid, the actual MuteIn/OssdIn-values are 0x{1,x}</Message>
  2118. </Event>
  2119. <Event>
  2120. <Id>14500</Id>
  2121. <Message LcId="1033">FB {0} (MUTING): State MUTING8, MutingEnable is set and the OssdIn-signals are invalid, the actual MuteIn/OssdIn-values are 0x{1,x}</Message>
  2122. </Event>
  2123. <Event>
  2124. <Id>14501</Id>
  2125. <Message LcId="1033">FB {0} (MUTING): State MUTING8, Sequential Inputs=TRUE, CheckOssdOptional=TRUE: MutingEnable is set and the OssdIn-signals are invalid, the actual MuteIn/OssdIn-values are 0x{1,x}</Message>
  2126. </Event>
  2127. <Event>
  2128. <Id>14502</Id>
  2129. <Message LcId="1033">FB {0} (MUTING): State MUTING8, Sequential Inputs=TRUE: MutingEnable is set and the MuteIn-signals are invalid, the actual MuteIn/OssdIn-values are 0x{1,x}</Message>
  2130. </Event>
  2131. <Event>
  2132. <Id>14503</Id>
  2133. <Message LcId="1033">FB {0} (MUTING): State MUTING8, Sequential Inputs=FALSE: MutingEnable is set and the MuteIn-signals are invalid, the actual MuteIn/OssdIn-values are 0x{1,x}</Message>
  2134. </Event>
  2135. <Event>
  2136. <Id>14504</Id>
  2137. <Message LcId="1033">FB {0} (MUTING): State MUTING9, MutingEnable is set and the OssdIn-signals are invalid, the actual MuteIn/OssdIn-values are 0x{1,x}</Message>
  2138. </Event>
  2139. <Event>
  2140. <Id>14505</Id>
  2141. <Message LcId="1033">FB {0} (MUTING): State MUTING9, MutingEnable is set and the MuteIn-signals are invalid, the actual MuteIn/OssdIn-values are 0x{1,x}</Message>
  2142. </Event>
  2143. <Event>
  2144. <Id>14506</Id>
  2145. <Message LcId="1033">FB {0} (MUTING): State MUTING5, Sequential Inputs=TRUE, MuteIn3 and MuteIn4 are inactive: MutingEnable is set and the MuteIn-signals are invalid, the actual MuteIn/OssdIn-values are 0x{1,x}</Message>
  2146. </Event>
  2147. <Event>
  2148. <Id>14507</Id>
  2149. <Message LcId="1033">FB {0} (MUTING): State MUTING6, Sequential Inputs=TRUE, MuteIn3 and MuteIn4 are inactive: MutingEnable is set and the MuteIn-signals are invalid, the actual MuteIn/OssdIn-values are 0x{1,x}</Message>
  2150. </Event>
  2151. <Event>
  2152. <Id>14508</Id>
  2153. <Message LcId="1033">FB {0} (MUTING): State MUTING1, MutingEnable is set and the MuteIn-signals are invalid, the actual MuteIn/OssdIn-values are 0x{1,x}</Message>
  2154. </Event>
  2155. <Event>
  2156. <Id>14512</Id>
  2157. <Message LcId="1033">FB {0} (MUTING): At least one activated EDM-Input was not reset in RUN when the EDM Reset time had been expired (Diag-Code=0x{1,x})</Message>
  2158. </Event>
  2159. <Event>
  2160. <Id>14529</Id>
  2161. <Message LcId="1033">FB {0} (MUTING): The Max-Muting-Time had been expired in state MUTING1 (Digital Inputs=0x{1,x})</Message>
  2162. </Event>
  2163. <Event>
  2164. <Id>14530</Id>
  2165. <Message LcId="1033">FB {0} (MUTING): The Max-Muting-Time had been expired in state MUTING2 (Digital Inputs=0x{1,x})</Message>
  2166. </Event>
  2167. <Event>
  2168. <Id>14531</Id>
  2169. <Message LcId="1033">FB {0} (MUTING): The Max-Muting-Time had been expired in state MUTING3 (Digital Inputs=0x{1,x})</Message>
  2170. </Event>
  2171. <Event>
  2172. <Id>14532</Id>
  2173. <Message LcId="1033">FB {0} (MUTING): The Max-Muting-Time had been expired in state MUTING4 (Digital Inputs=0x{1,x})</Message>
  2174. </Event>
  2175. <Event>
  2176. <Id>14533</Id>
  2177. <Message LcId="1033">FB {0} (MUTING): The Max-Muting-Time had been expired in state MUTING5 (Digital Inputs=0x{1,x})</Message>
  2178. </Event>
  2179. <Event>
  2180. <Id>14534</Id>
  2181. <Message LcId="1033">FB {0} (MUTING): The Max-Muting-Time had been expired in state MUTING6 (Digital Inputs=0x{1,x})</Message>
  2182. </Event>
  2183. <Event>
  2184. <Id>14535</Id>
  2185. <Message LcId="1033">FB {0} (MUTING): The Max-Muting-Time had been expired in state MUTING7 (Digital Inputs=0x{1,x})</Message>
  2186. </Event>
  2187. <Event>
  2188. <Id>14536</Id>
  2189. <Message LcId="1033">FB {0} (MUTING): The Max-Muting-Time had been expired in state MUTING8 (Digital Inputs=0x{1,x})</Message>
  2190. </Event>
  2191. <Event>
  2192. <Id>14537</Id>
  2193. <Message LcId="1033">FB {0} (MUTING): The Max-Muting-Time had been expired in state MUTING9 (Digital Inputs=0x{1,x})</Message>
  2194. </Event>
  2195. <Event>
  2196. <Id>16385</Id>
  2197. <Message LcId="1033">FB {0} (CAMMON): The TDC2UpperLimit ({1}) is lower or equal than the maximum position jitter ({2})</Message>
  2198. </Event>
  2199. <Event>
  2200. <Id>16386</Id>
  2201. <Message LcId="1033">FB {0} (CAMMON): The Position ({1}) is bigger than the maximum position (plus the maximum position jitter) ({2})</Message>
  2202. </Event>
  2203. <Event>
  2204. <Id>16387</Id>
  2205. <Message LcId="1033">FB {0} (CAMMON): The input OverrunCAM was FALSE in the top dead center area, the actual position is {1}</Message>
  2206. </Event>
  2207. <Event>
  2208. <Id>16388</Id>
  2209. <Message LcId="1033">FB {0} (CAMMON): The input OverrunCAM changed from FALSE to TRUE outside the area between BDCUpperLimit and TDCLowerLimit, the actual position is {1}</Message>
  2210. </Event>
  2211. <Event>
  2212. <Id>16389</Id>
  2213. <Message LcId="1033">FB {0} (CAMMON): The input OverrunCAM was TRUE in the area between OverrunMax and BDCUpperLimit, the actual position is {1}</Message>
  2214. </Event>
  2215. <Event>
  2216. <Id>16390</Id>
  2217. <Message LcId="1033">FB {0} (CAMMON): The input OverrunCAM changed from TRUE to FALSE outside the area between OverrunMax and BDCLowerLimit, the actual position is {1}</Message>
  2218. </Event>
  2219. <Event>
  2220. <Id>16391</Id>
  2221. <Message LcId="1033">FB {0} (CAMMON): The input UpwardsCAM was FALSE in the area between BDCUpperLimit and TDCLowerLimit, the actual position is {1}</Message>
  2222. </Event>
  2223. <Event>
  2224. <Id>16392</Id>
  2225. <Message LcId="1033">FB {0} (CAMMON): The input UpwardsCAM changed from FALSE to TRUE outside the area between BDCLowerLimit and TDCLowerLimit, the actual position is {1}</Message>
  2226. </Event>
  2227. <Event>
  2228. <Id>16393</Id>
  2229. <Message LcId="1033">FB {0} (CAMMON): The input UpwardsCAM changed from TRUE to FALSE outside the area between TDCLowerLimit and OverrunMax, the actual position is {1}</Message>
  2230. </Event>
  2231. <Event>
  2232. <Id>16394</Id>
  2233. <Message LcId="1033">FB {0} (CAMMON): The Position was moving while waiting for a rising edge of the input Reset in the state MOVE-STOP</Message>
  2234. </Event>
  2235. <Event>
  2236. <Id>16395</Id>
  2237. <Message LcId="1033">FB {0} (CAMMON): The Position was moving while waiting for a falling edge of the input Reset in the state MOVE-START</Message>
  2238. </Event>
  2239. <Event>
  2240. <Id>16396</Id>
  2241. <Message LcId="1033">FB {0} (CAMMON): The Position {1} in the area between OverrunMax and BDCLowerLimit was detected in the state MOVE-UP</Message>
  2242. </Event>
  2243. <Event>
  2244. <Id>16397</Id>
  2245. <Message LcId="1033">FB {0} (CAMMON): The Position has left the top dead center while waiting for a stop, the actual position is {1}</Message>
  2246. </Event>
  2247. <Event>
  2248. <Id>16398</Id>
  2249. <Message LcId="1033">FB {0} (CAMMON): The Position has been changed negative</Message>
  2250. </Event>
  2251. <Event>
  2252. <Id>16399</Id>
  2253. <Message LcId="1033">FB {0} (CAMMON): The input UpwardsCAM was TRUE in the area between OverrunMax and BDCLowerLimit</Message>
  2254. </Event>
  2255. <Event>
  2256. <Id>16400</Id>
  2257. <Message LcId="1033">FB {0} (CAMMON): The Position has a circle overflow in Pendulum Mode, actual position={1}, last position={2}</Message>
  2258. </Event>
  2259. <Event>
  2260. <Id>16401</Id>
  2261. <Message LcId="1033">FB {0} (CAMMON): The Position has moved while waiting for a rising edge of the input Reset in Pendulum Mode, actual position={1}, compare position={2}</Message>
  2262. </Event>
  2263. <Event>
  2264. <Id>16402</Id>
  2265. <Message LcId="1033">FB {0} (CAMMON): The Input BackwardsMove is TRUE while the Position is between 180° and 360°, the actual position is {1}</Message>
  2266. </Event>
  2267. <Event>
  2268. <Id>16403</Id>
  2269. <Message LcId="1033">FB {0} (CAMMON): The Input BackwardsMove is TRUE while the moving is clockwise</Message>
  2270. </Event>
  2271. <Event>
  2272. <Id>16404</Id>
  2273. <Message LcId="1033">FB {0} (CAMMON): The Position has moved while waiting for a falling edge of the input Reset in Pendulum Mode, actual position={1}, last position={2}</Message>
  2274. </Event>
  2275. <Event>
  2276. <Id>16405</Id>
  2277. <Message LcId="1033">FB {0} (CAMMON): The value of TDCLowerLimit (plus maximum position jitter) ({1}) is bigger or equal the configured position of 360° ({2})</Message>
  2278. </Event>
  2279. <Event>
  2280. <Id>16406</Id>
  2281. <Message LcId="1033">FB {0} (CAMMON): The value of BDCUpperLimit (plus twice the maximum position jitter) ({1}) is bigger or equal the value of TDCLowerLimit ({2})</Message>
  2282. </Event>
  2283. <Event>
  2284. <Id>16407</Id>
  2285. <Message LcId="1033">FB {0} (CAMMON): The value of BDCUpperLimit ({1}) is smaller or equal the configured value of 180° (plus maximum position jitter) ({2})</Message>
  2286. </Event>
  2287. <Event>
  2288. <Id>16408</Id>
  2289. <Message LcId="1033">FB {0} (CAMMON): The value of BDCLowerLimit (plus maximum position jitter) ({1}) is greater or equal the configured value of 180° ({2})</Message>
  2290. </Event>
  2291. <Event>
  2292. <Id>16409</Id>
  2293. <Message LcId="1033">FB {0} (CAMMON): The value of OverrunMax (plus twice the maximum position jitter) ({1}) is bigger or equal the value of BDCLowerLimit ({2})</Message>
  2294. </Event>
  2295. <Event>
  2296. <Id>16410</Id>
  2297. <Message LcId="1033">FB {0} (CAMMON): The value of TDCUpperLimit (plus twice the maximum position jitter) ({1}) is bigger or equal the value of OverrunMax ({2})</Message>
  2298. </Event>
  2299. <Event>
  2300. <Id>16411</Id>
  2301. <Message LcId="1033">FB {0} (CAMMON): The value of TDC1UpperLimit (plus the maximum position jitter) ({1}) is bigger or equal the configured position of 360° ({2})</Message>
  2302. </Event>
  2303. <Event>
  2304. <Id>16412</Id>
  2305. <Message LcId="1033">FB {0} (CAMMON): The value of TDC1LowerLimit (plus twice the maximum position jitter) ({1}) is bigger or equal the value of TDC1UpperLimit (5d)</Message>
  2306. </Event>
  2307. <Event>
  2308. <Id>16413</Id>
  2309. <Message LcId="1033">FB {0} (CAMMON): The value of TDC2LowerLimit (plus twice the maximum position jitter) ({1}) is bigger or equal the value of BDCLowerLimit ({2})</Message>
  2310. </Event>
  2311. <Event>
  2312. <Id>16414</Id>
  2313. <Message LcId="1033">FB {0} (CAMMON): The value of TDC2UpperLimit (plus twice the maximum position jitter) ({1}) is bigger or equal the value of TDC2LowerLimit ({2})</Message>
  2314. </Event>
  2315. <Event>
  2316. <Id>16415</Id>
  2317. <Message LcId="1033">FB {0} (CAMMON): The input PressStarted is TRUE and the position did not move after the PressStartedDelayTime</Message>
  2318. </Event>
  2319. <Event>
  2320. <Id>16416</Id>
  2321. <Message LcId="1033">FB {0} (CAMMON): The input PressStarted is TRUE and the position has stopped after moving before</Message>
  2322. </Event>
  2323. <Event>
  2324. <Id>16417</Id>
  2325. <Message LcId="1033">FB {0} (CAMMON): The input PressStarted is TRUE and the position has not moved enough, the actual position is {1}, the compare position is {2}</Message>
  2326. </Event>
  2327. <Event>
  2328. <Id>16418</Id>
  2329. <Message LcId="1033">FB {0} (CAMMON), Pendulum Mode: The Position has changed contra clockwise while moving up clockwise (actual Position={1}, old Position={2})</Message>
  2330. </Event>
  2331. <Event>
  2332. <Id>16419</Id>
  2333. <Message LcId="1033">FB {0} (CAMMON), Pendulum Mode: The Position has changed clockwise while moving up contra clockwise (actual Position={1}, old Position={2})</Message>
  2334. </Event>
  2335. <Event>
  2336. <Id>16420</Id>
  2337. <Message LcId="1033">FB {0} (CAMMON): The Position was moving while waiting for a falling edge of the input Reset in the state WAIT-FOR_RESET</Message>
  2338. </Event>
  2339. <Event>
  2340. <Id>16421</Id>
  2341. <Message LcId="1033">FB {0} (CAMMON): The TDCUpperLimit ({1}) is lower or equal than the maximum position jitter ({2})</Message>
  2342. </Event>
  2343. <Event>
  2344. <Id>16512</Id>
  2345. <Message LcId="1033">FB {0} (ADD/SUB): an underflow was detected, AnalogIn1={1}, AnalogIn2={2}</Message>
  2346. </Event>
  2347. <Event>
  2348. <Id>16513</Id>
  2349. <Message LcId="1033">FB {0} (ADD/SUB): an overflow was detected, AnalogIn1={1}, AnalogIn2={2}</Message>
  2350. </Event>
  2351. <Event>
  2352. <Id>16520</Id>
  2353. <Message LcId="1033">FB {0} (SPEED): an underflow was detected, actual Position={1}, old Position={2}</Message>
  2354. </Event>
  2355. <Event>
  2356. <Id>16521</Id>
  2357. <Message LcId="1033">FB {0} (SPEED): an overflow was detected, actual Position={1}, old Position={2}</Message>
  2358. </Event>
  2359. <Event>
  2360. <Id>16528</Id>
  2361. <Message LcId="1033">FB {0} (LIMIT): the minimum value ({1}) is bigger than the maximum value ({2})</Message>
  2362. </Event>
  2363. <Event>
  2364. <Id>16536</Id>
  2365. <Message LcId="1033">FB {0} (COMPARE): an underflow was detected on CompOut ({1}), the minimum allowed value is {2}</Message>
  2366. </Event>
  2367. <Event>
  2368. <Id>16537</Id>
  2369. <Message LcId="1033">FB {0} (COMPARE): an overflow was detected on CompOut ({1}), the maximum allowed value is {2}</Message>
  2370. </Event>
  2371. <Event>
  2372. <Id>16544</Id>
  2373. <Message LcId="1033">FB {0} (MUL): an underflow was detected, AnalogIn1={1}, AnalogIn2={2}</Message>
  2374. </Event>
  2375. <Event>
  2376. <Id>16545</Id>
  2377. <Message LcId="1033">FB {0} (MUL): an overflow was detected, AnalogIn1={1}, AnalogIn2={2}</Message>
  2378. </Event>
  2379. <Event>
  2380. <Id>16552</Id>
  2381. <Message LcId="1033">FB {0} (DIV): an underflow was detected, AnalogIn1={1}, AnalogIn2={2}</Message>
  2382. </Event>
  2383. <Event>
  2384. <Id>16553</Id>
  2385. <Message LcId="1033">FB {0} (DIV): an overflow was detected, AnalogIn1={1}, AnalogIn2={2}</Message>
  2386. </Event>
  2387. <Event>
  2388. <Id>16560</Id>
  2389. <Message LcId="1033">FB {0} (SCALE): an underflow was detected, AnalogIn={1}</Message>
  2390. </Event>
  2391. <Event>
  2392. <Id>16561</Id>
  2393. <Message LcId="1033">FB {0} (SCALE): an overflow was detected, AnalogIn={1}</Message>
  2394. </Event>
  2395. <Event>
  2396. <Id>16562</Id>
  2397. <Message LcId="1033">FB {0} (SCALE): an overflow was detected after multiplication, AnalogIn={1}</Message>
  2398. </Event>
  2399. <Event>
  2400. <Id>16563</Id>
  2401. <Message LcId="1033">FB {0} (SCALE): an overflow was detected before division when rounding up the value, AnalogIn={1}</Message>
  2402. </Event>
  2403. <Event>
  2404. <Id>16568</Id>
  2405. <Message LcId="1033">FB {0} (COUNT): an underflow was detected on ActValue ({1})</Message>
  2406. </Event>
  2407. <Event>
  2408. <Id>16569</Id>
  2409. <Message LcId="1033">FB {0} (COUNT): an overflow was detected on ActValue ({1})</Message>
  2410. </Event>
  2411. <Event>
  2412. <Id>16576</Id>
  2413. <Message LcId="1033">FB {0} (SLI): an underflow was detected on ActValue ({1}), the minimum allowed value is {2}</Message>
  2414. </Event>
  2415. <Event>
  2416. <Id>16577</Id>
  2417. <Message LcId="1033">FB {0} (SLI): an overflow was detected on ActValue ({1}), the maximum allowed value is {2}</Message>
  2418. </Event>
  2419. <Event>
  2420. <Id>16584</Id>
  2421. <Message LcId="1033">FB {0} (ENVELOPE): an underflow was detected on InValue ({1}), the minimum allowed value is {2}</Message>
  2422. </Event>
  2423. <Event>
  2424. <Id>16585</Id>
  2425. <Message LcId="1033">FB {0} (ENVELOPE): an overflow was detected on InValue ({1}), the maximum allowed value is {2}</Message>
  2426. </Event>
  2427. <Event>
  2428. <Id>16586</Id>
  2429. <Message LcId="1033">FB {0} (ENVELOPE): an overflow error was detected on InValue ({1}), InValue+Offset is bigger than the maximum allowed value</Message>
  2430. </Event>
  2431. <Event>
  2432. <Id>16587</Id>
  2433. <Message LcId="1033">FB {0} (ENVELOPE): the MaxTime was expired (InValue={1})</Message>
  2434. </Event>
  2435. <Event>
  2436. <Id>16592</Id>
  2437. <Message LcId="1033">FB {0} (SLP): MultiturnPos_LL ({1}) is bigger than MultiturnPos_UL ({2})</Message>
  2438. </Event>
  2439. <Event>
  2440. <Id>16593</Id>
  2441. <Message LcId="1033">FB {0} (SLP): MultiturnPos_LL=MultiturnPos_UL and SingleturnPos_LL ({1}) is bigger than SingleturnPos_UL ({2})</Message>
  2442. </Event>
  2443. <Event>
  2444. <Id>16600</Id>
  2445. <Message LcId="1033">FB {0} (SBT): Brake-Test failed in state {1}</Message>
  2446. </Event>
  2447. <Event>
  2448. <Id>16601</Id>
  2449. <Message LcId="1033">FB {0} (SBT): Brake-Test Interval expired in state {1}</Message>
  2450. </Event>
  2451. <Event>
  2452. <Id>16602</Id>
  2453. <Message LcId="1033">FB {0} (SBT): Brake-Test failed, Actual Position Deviation={1}, Maximum Position Deviation={2}Interval expired in state {3}</Message>
  2454. </Event>
  2455. <Event>
  2456. <Id>24585</Id>
  2457. <Message LcId="1033">SAFEOUT:Initial-Parameter: MultiplierDiagTestPulse has to be greater zero. ModuleNr:0x{0,x}</Message>
  2458. </Event>
  2459. <Event>
  2460. <Id>24592</Id>
  2461. <Message LcId="1033">SAFEOUT:Initial-Parameter: Number of Modules incorrect. ModuleNr:0x{0,x}, Parameter:0x{1,x}</Message>
  2462. </Event>
  2463. <Event>
  2464. <Id>24593</Id>
  2465. <Message LcId="1033">SAFEOUT:Initial-Parameter: Number of Channels incorrect. Parameter0:0x{0,x}, Parameter1:0x{1,x}, Parameter2:0x{2,x}</Message>
  2466. </Event>
  2467. <Event>
  2468. <Id>24594</Id>
  2469. <Message LcId="1033">SAFEOUT:Initial-Parameter: Number of Diagnosis active Module incorrect. Parameter0:0x{0,x}, Parameter1:0x{1,x}, Parameter2:0x{2,x}</Message>
  2470. </Event>
  2471. <Event>
  2472. <Id>24595</Id>
  2473. <Message LcId="1033">SAFEOUT:Initial-Parameter: Number of Diagnosis inactive Module incorrect. Parameter0:0x{0,x}, Parameter1:0x{1,x}, Parameter2:0x{2,x}</Message>
  2474. </Event>
  2475. <Event>
  2476. <Id>24596</Id>
  2477. <Message LcId="1033">SAFEOUT:Initial-Parameter: Number of Feedback active Module incorrect. Parameter0:0x{0,x}, Parameter1:0x{1,x}, Parameter2:0x{2,x}</Message>
  2478. </Event>
  2479. <Event>
  2480. <Id>24597</Id>
  2481. <Message LcId="1033">SAFEOUT:Initial-Parameter: Number of Feedback Diagnosis active Module incorrect. Parameter0:0x{0,x}, Parameter1:0x{1,x}, Parameter2:0x{2,x}</Message>
  2482. </Event>
  2483. <Event>
  2484. <Id>24598</Id>
  2485. <Message LcId="1033">SAFEOUT:Initial-Parameter: Number of Feedback inactive Module incorrect. Parameter0:0x{0,x}, Parameter1:0x{1,x}, Parameter2:0x{2,x}</Message>
  2486. </Event>
  2487. <Event>
  2488. <Id>24599</Id>
  2489. <Message LcId="1033">SAFEOUT:Initial-Parameter: Number of Feedback Diagnosis inactive Module incorrect. Parameter0:0x{0,x}, Parameter1:0x{1,x}, Parameter2:0x{2,x}</Message>
  2490. </Event>
  2491. <Event>
  2492. <Id>24600</Id>
  2493. <Message LcId="1033">SAFEOUT:Initial-Parameter: Number of Diagnosis active Channel incorrect. Parameter0:0x{0,x}, Parameter1:0x{1,x}, Parameter2:0x{2,x}</Message>
  2494. </Event>
  2495. <Event>
  2496. <Id>24601</Id>
  2497. <Message LcId="1033">SAFEOUT:Initial-Parameter: Number of Diagnosis inactive Channel incorrect. Parameter0:0x{0,x}, Parameter1:0x{1,x}, Parameter2:0x{2,x}</Message>
  2498. </Event>
  2499. <Event>
  2500. <Id>24602</Id>
  2501. <Message LcId="1033">SAFEOUT:Initial-Parameter: Number of Feedback active Channel incorrect. Parameter0:0x{0,x}, Parameter1:0x{1,x}, Parameter2:0x{2,x}</Message>
  2502. </Event>
  2503. <Event>
  2504. <Id>24603</Id>
  2505. <Message LcId="1033">SAFEOUT:Initial-Parameter: Number of Feedback Diagnosis active Channel incorrect. Parameter0:0x{0,x}, Parameter1:0x{1,x}, Parameter2:0x{2,x}</Message>
  2506. </Event>
  2507. <Event>
  2508. <Id>24604</Id>
  2509. <Message LcId="1033">SAFEOUT:Initial-Parameter: Number of Feedback inactive Channel incorrect. Parameter0:0x{0,x}, Parameter1:0x{1,x}, Parameter2:0x{2,x}</Message>
  2510. </Event>
  2511. <Event>
  2512. <Id>24605</Id>
  2513. <Message LcId="1033">SAFEOUT:Initial-Parameter: Number of Feedback Diagnosis inactive Channel incorrect. Parameter0:0x{0,x}, Parameter1:0x{1,x}, Parameter2:0x{2,x}</Message>
  2514. </Event>
  2515. <Event>
  2516. <Id>24606</Id>
  2517. <Message LcId="1033">SAFEOUT:Setup Hardware Fault: Module Switch. ReturnData:0x{0,x}, ReturnState:0x{1,x}</Message>
  2518. </Event>
  2519. <Event>
  2520. <Id>24607</Id>
  2521. <Message LcId="1033">SAFEOUT:Setup Hardware Fault: Diagnosis active Module. ReturnData:0x{0,x}, ReturnState:0x{1,x}</Message>
  2522. </Event>
  2523. <Event>
  2524. <Id>24608</Id>
  2525. <Message LcId="1033">SAFEOUT:Setup Hardware Fault: Diagnosis inactive Module. ReturnData:0x{0,x}, ReturnState:0x{1,x}</Message>
  2526. </Event>
  2527. <Event>
  2528. <Id>24609</Id>
  2529. <Message LcId="1033">SAFEOUT:Setup Hardware Fault: Feedback active Module. ReturnData:0x{0,x}, ReturnState:0x{1,x}</Message>
  2530. </Event>
  2531. <Event>
  2532. <Id>24610</Id>
  2533. <Message LcId="1033">SAFEOUT:Setup Hardware Fault: Feedback Diagnosis active Module. ReturnData:0x{0,x}, ReturnState:0x{1,x}</Message>
  2534. </Event>
  2535. <Event>
  2536. <Id>24611</Id>
  2537. <Message LcId="1033">SAFEOUT:Setup Hardware Fault: Feedback inactive Module. ReturnData:0x{0,x}, ReturnState:0x{1,x}</Message>
  2538. </Event>
  2539. <Event>
  2540. <Id>24612</Id>
  2541. <Message LcId="1033">SAFEOUT:Setup Hardware Fault: Feedback Diagnosis inactive Module. ReturnData:0x{0,x}, ReturnState:0x{1,x}</Message>
  2542. </Event>
  2543. <Event>
  2544. <Id>24613</Id>
  2545. <Message LcId="1033">SAFEOUT:Setup Hardware Fault: Channel Switch. ReturnData:0x{0,x}, ReturnState:0x{1,x}</Message>
  2546. </Event>
  2547. <Event>
  2548. <Id>24614</Id>
  2549. <Message LcId="1033">SAFEOUT:Setup Hardware Fault: Diagnosis active Channel. ReturnData:0x{0,x}, ReturnState:0x{1,x}</Message>
  2550. </Event>
  2551. <Event>
  2552. <Id>24615</Id>
  2553. <Message LcId="1033">SAFEOUT:Setup Hardware Fault: Diagnosis inactive Channel. ReturnData:0x{0,x}, ReturnState:0x{1,x}</Message>
  2554. </Event>
  2555. <Event>
  2556. <Id>24616</Id>
  2557. <Message LcId="1033">SAFEOUT:Setup Hardware Fault: Feedback active Channel. ReturnData:0x{0,x}, ReturnState:0x{1,x}</Message>
  2558. </Event>
  2559. <Event>
  2560. <Id>24617</Id>
  2561. <Message LcId="1033">SAFEOUT:Setup Hardware Fault: Feedback Diagnosis active Channel. ReturnData:0x{0,x}, ReturnState:0x{1,x}</Message>
  2562. </Event>
  2563. <Event>
  2564. <Id>24618</Id>
  2565. <Message LcId="1033">SAFEOUT:Setup Hardware Fault: Feedback inactive Channel. ReturnData:0x{0,x}, ReturnState:0x{1,x}</Message>
  2566. </Event>
  2567. <Event>
  2568. <Id>24619</Id>
  2569. <Message LcId="1033">SAFEOUT:Setup Hardware Fault: Feedback Diagnosis inactive Channel. ReturnData:0x{0,x}, ReturnState:0x{1,x}</Message>
  2570. </Event>
  2571. <Event>
  2572. <Id>24624</Id>
  2573. <Message LcId="1033">SAFEOUT:The Feedback of the active Module Switch is wrong. Module:0x{0,x}</Message>
  2574. </Event>
  2575. <Event>
  2576. <Id>24625</Id>
  2577. <Message LcId="1033">SAFEOUT:The Feedback of the inactive Module Switch is wrong. Module:0x{0,x}</Message>
  2578. </Event>
  2579. <Event>
  2580. <Id>24626</Id>
  2581. <Message LcId="1033">SAFEOUT:The Feedback of the active Channel Switch is wrong. Module:0x{0,x} / Channel:0x{1,x}</Message>
  2582. </Event>
  2583. <Event>
  2584. <Id>24627</Id>
  2585. <Message LcId="1033">SAFEOUT:The Feedback of the inactive Channel Switch is wrong. Module:0x{0,x} / Channel:0x{1,x}</Message>
  2586. </Event>
  2587. <Event>
  2588. <Id>24640</Id>
  2589. <Message LcId="1033">SAFEOUT:Diagnosis Test: Common Fault Module:0x{0,x} / DiagChannel:0x{1,x}</Message>
  2590. </Event>
  2591. <Event>
  2592. <Id>24641</Id>
  2593. <Message LcId="1033">SAFEOUT:Diagnosis Test: Unknown State local ModuleState:0x{0,x}</Message>
  2594. </Event>
  2595. <Event>
  2596. <Id>24642</Id>
  2597. <Message LcId="1033">SAFEOUT:Diagnosis Test: Unknown State other ModuleState:0x{0,x}</Message>
  2598. </Event>
  2599. <Event>
  2600. <Id>24656</Id>
  2601. <Message LcId="1033">SAFEOUT:Diagnosis Test: Feedback active Module Switch is wrong (Step1 - check current state). Module:0x{0,x}</Message>
  2602. </Event>
  2603. <Event>
  2604. <Id>24657</Id>
  2605. <Message LcId="1033">SAFEOUT:Diagnosis Test: Feedback inactive Module Switch is wrong (Step1 - check current state). Module:0x{0,x}</Message>
  2606. </Event>
  2607. <Event>
  2608. <Id>24658</Id>
  2609. <Message LcId="1033">SAFEOUT:Diagnosis Test: Feedback active Channel Switch is wrong (Step1 - check current state). Module:0x{0,x} / DiagChannel:0x{1,x}</Message>
  2610. </Event>
  2611. <Event>
  2612. <Id>24659</Id>
  2613. <Message LcId="1033">SAFEOUT:Diagnosis Test: Feedback inactive Channel Switch is wrong (Step1 - check current state). Module:0x{0,x} / DiagChannel:0x{1,x}</Message>
  2614. </Event>
  2615. <Event>
  2616. <Id>24672</Id>
  2617. <Message LcId="1033">SAFEOUT:Diagnosis Test: Feedback active Module Switch is wrong (Step2 - check test pulse). Module:0x{0,x}</Message>
  2618. </Event>
  2619. <Event>
  2620. <Id>24673</Id>
  2621. <Message LcId="1033">SAFEOUT:Diagnosis Test: Feedback inactive Module Switch is wrong (Step2 - check test pulse). Module:0x{0,x}</Message>
  2622. </Event>
  2623. <Event>
  2624. <Id>24674</Id>
  2625. <Message LcId="1033">SAFEOUT:Diagnosis Test: Feedback active Channel Switch is wrong (Step2 - check test pulse). Module:0x{0,x} / DiagChannel:0x{1,x}</Message>
  2626. </Event>
  2627. <Event>
  2628. <Id>24675</Id>
  2629. <Message LcId="1033">SAFEOUT:Diagnosis Test: Feedback inactive Channel Switch is wrong (Step2 - check test pulse). Module:0x{0,x} / DiagChannel:0x{1,x}</Message>
  2630. </Event>
  2631. <Event>
  2632. <Id>24704</Id>
  2633. <Message LcId="1033">SAFEOUT:Diagnosis Test:VendorData. ID: 0x{0,x} Module:0x{1,x}</Message>
  2634. </Event>
  2635. <Event>
  2636. <Id>24705</Id>
  2637. <Message LcId="1033">SAFEOUT:Diagnosis Test:VendorData. ID: 0x{0,x} Module:0x{1,x}</Message>
  2638. </Event>
  2639. <Event>
  2640. <Id>24706</Id>
  2641. <Message LcId="1033">SAFEOUT:Diagnosis Test:VendorData. ID: 0x{0,x} Module:0x{1,x}</Message>
  2642. </Event>
  2643. <Event>
  2644. <Id>24707</Id>
  2645. <Message LcId="1033">SAFEOUT:Diagnosis Test:VendorData. Channel: 0x{0,x} Module:0x{1,x}</Message>
  2646. </Event>
  2647. <Event>
  2648. <Id>24708</Id>
  2649. <Message LcId="1033">SAFEOUT:Diagnosis Test:VendorData. Channel: 0x{0,x} Module:0x{1,x}</Message>
  2650. </Event>
  2651. <Event>
  2652. <Id>24709</Id>
  2653. <Message LcId="1033">SAFEOUT:Diagnosis Test:VendorData. Channel: 0x{0,x} Module:0x{1,x}</Message>
  2654. </Event>
  2655. <Event>
  2656. <Id>24710</Id>
  2657. <Message LcId="1033">SAFEOUT:Diagnosis Test:VendorData. Channel: 0x{0,x} Module:0x{1,x}</Message>
  2658. </Event>
  2659. <Event>
  2660. <Id>24720</Id>
  2661. <Message LcId="1033">SAFEOUT:Module Switch FeedbackTest ViolationCounter incremented, Outputs active. Module:0x{0,x}, Info:0x{1,x}.</Message>
  2662. </Event>
  2663. <Event>
  2664. <Id>24721</Id>
  2665. <Message LcId="1033">SAFEOUT:Module Switch FeedbackTest ViolationCounter incremented, Outputs inactive. Module:0x{0,x}, Info:0x{1,x}.</Message>
  2666. </Event>
  2667. <Event>
  2668. <Id>24722</Id>
  2669. <Message LcId="1033">SAFEOUT:Channel Switch FeedbackTest ViolationCounter incremented, Outputs active. Module:0x{0,x}, Channel:0x{1,x}, Info:0x{2,x}.</Message>
  2670. </Event>
  2671. <Event>
  2672. <Id>24723</Id>
  2673. <Message LcId="1033">SAFEOUT:Channel Switch FeedbackTest ViolationCounter incremented, Outputs inactive. Module:0x{0,x}, Channel:0x{1,x}, Info:0x{2,x}.</Message>
  2674. </Event>
  2675. <Event>
  2676. <Id>24724</Id>
  2677. <Message LcId="1033">SAFEOUT:Module Switch DiagnosisTest ViolationCounter incremented, Outputs active (Step1 - check current state). Module:0x{0,x}, Info:0x{1,x}.</Message>
  2678. </Event>
  2679. <Event>
  2680. <Id>24725</Id>
  2681. <Message LcId="1033">SAFEOUT:Module Switch DiagnosisTest ViolationCounter incremented, Outputs inactive (Step1 - check current state). Module:0x{0,x}, Info:0x{1,x}.</Message>
  2682. </Event>
  2683. <Event>
  2684. <Id>24726</Id>
  2685. <Message LcId="1033">SAFEOUT:Channel Switch DiagnosisTest ViolationCounter incremented, Outputs active (Step1 - check current state). Module:0x{0,x}, Channel:0x{1,x}, Info:0x{2,x}.</Message>
  2686. </Event>
  2687. <Event>
  2688. <Id>24727</Id>
  2689. <Message LcId="1033">SAFEOUT:Channel Switch DiagnosisTest ViolationCounter incremented, Outputs inactive (Step1 - check current state). Module:0x{0,x}, Channel:0x{1,x}, Info:0x{2,x}.</Message>
  2690. </Event>
  2691. <Event>
  2692. <Id>24728</Id>
  2693. <Message LcId="1033">SAFEOUT:Module Switch DiagnosisTest ViolationCounter incremented, Outputs active (Step2 - check test pulse). Module:0x{0,x}, Info:0x{1,x}.</Message>
  2694. </Event>
  2695. <Event>
  2696. <Id>24729</Id>
  2697. <Message LcId="1033">SAFEOUT:Module Switch DiagnosisTest ViolationCounter incremented, Outputs inactive (Step2 - check test pulse). Module:0x{0,x}, Info:0x{1,x}.</Message>
  2698. </Event>
  2699. <Event>
  2700. <Id>24730</Id>
  2701. <Message LcId="1033">SAFEOUT:Channel Switch DiagnosisTest ViolationCounter incremented, Outputs active (Step2 - check test pulse). Module:0x{0,x}, Channel:0x{1,x}, Info:0x{2,x}.</Message>
  2702. </Event>
  2703. <Event>
  2704. <Id>24731</Id>
  2705. <Message LcId="1033">SAFEOUT:Channel Switch DiagnosisTest ViolationCounter incremented, Outputs inactive (Step2 - check test pulse). Module:0x{0,x}, Channel:0x{1,x}, Info:0x{2,x}.</Message>
  2706. </Event>
  2707. <Event>
  2708. <Id>24736</Id>
  2709. <Message LcId="1033">SAFEOUT:Sercom Fault 0. Cmd/State:0x{0,x}</Message>
  2710. </Event>
  2711. <Event>
  2712. <Id>24737</Id>
  2713. <Message LcId="1033">SAFEOUT:Sercom Fault 1. Cmd/State:0x{0,x}</Message>
  2714. </Event>
  2715. <Event>
  2716. <Id>24752</Id>
  2717. <Message LcId="1033">SAFEOUT:Unknown Sercom Command Request 1. Cmd/State:0x{0,x}</Message>
  2718. </Event>
  2719. <Event>
  2720. <Id>24753</Id>
  2721. <Message LcId="1033">SAFEOUT:Unknown Sercom Command Answer 1. Cmd/State:0x{0,x}</Message>
  2722. </Event>
  2723. <Event>
  2724. <Id>24754</Id>
  2725. <Message LcId="1033">SAFEOUT:Unknown Sercom Command Request 2. Cmd/State:0x{0,x}</Message>
  2726. </Event>
  2727. <Event>
  2728. <Id>24755</Id>
  2729. <Message LcId="1033">SAFEOUT:Unknown Sercom Command Answer 2. Cmd/State:0x{0,x}</Message>
  2730. </Event>
  2731. <Event>
  2732. <Id>24768</Id>
  2733. <Message LcId="1033">SAFEOUT:Module Switch too fast Switching OFF detected Fault (see technical data). Module:0x{0,x}</Message>
  2734. </Event>
  2735. <Event>
  2736. <Id>24769</Id>
  2737. <Message LcId="1033">SAFEOUT:Channel Switch too fast Switching OFF detected Fault (see technical data). Module:0x{0,x} / Channel:0x{1,x}</Message>
  2738. </Event>
  2739. <Event>
  2740. <Id>24770</Id>
  2741. <Message LcId="1033">SAFEOUT:Module Switch too fast Switching ON detected Fault (see technical data). Module:0x{0,x}</Message>
  2742. </Event>
  2743. <Event>
  2744. <Id>24771</Id>
  2745. <Message LcId="1033">SAFEOUT:Channel Switch too fast Switching ON detected Fault (see technical data). Module:0x{0,x} / Channel:0x{1,x}</Message>
  2746. </Event>
  2747. <Event>
  2748. <Id>24772</Id>
  2749. <Message LcId="1033">SAFEOUT:Module Error Acknowledge is not possible. Module:0x{0,x}</Message>
  2750. </Event>
  2751. <Event>
  2752. <Id>24800</Id>
  2753. <Message LcId="1033">SAFEOUT:HAL Read Fault. ReturnData:0x{0,x}</Message>
  2754. </Event>
  2755. <Event>
  2756. <Id>24801</Id>
  2757. <Message LcId="1033">SAFEOUT:Init Fault. Module:0x{0,x}</Message>
  2758. </Event>
  2759. <Event>
  2760. <Id>32777</Id>
  2761. <Message LcId="1033">SAFEIN:Initial-Parameter: MultiplierDiagTestPulse has to be greater zero. ModuleNr:0x{0,x}</Message>
  2762. </Event>
  2763. <Event>
  2764. <Id>32784</Id>
  2765. <Message LcId="1033">SAFEIN:Initial-Parameter: Number of Modules incorrect. ModuleNr:0x{0,x}, Parameter:0x{1,x}</Message>
  2766. </Event>
  2767. <Event>
  2768. <Id>32785</Id>
  2769. <Message LcId="1033">SAFEIN:Initial-Parameter: Number of Channels incorrect. Parameter0:0x{0,x}, Parameter1:0x{1,x}, Parameter2:0x{2,x}</Message>
  2770. </Event>
  2771. <Event>
  2772. <Id>32792</Id>
  2773. <Message LcId="1033">SAFEIN:Initial-Parameter: Number of Diagnosis active Channel incorrect. Parameter0:0x{0,x}, Parameter1:0x{1,x}, Parameter2:0x{2,x}</Message>
  2774. </Event>
  2775. <Event>
  2776. <Id>32795</Id>
  2777. <Message LcId="1033">SAFEIN:Initial-Parameter: Number of Feedback Diagnosis active Channel incorrect. Parameter0:0x{0,x}, Parameter1:0x{1,x}, Parameter2:0x{2,x}</Message>
  2778. </Event>
  2779. <Event>
  2780. <Id>32805</Id>
  2781. <Message LcId="1033">SAFEIN:Setup Hardware Fault: Channel Switch. ReturnData:0x{0,x}, ReturnState:0x{1,x}</Message>
  2782. </Event>
  2783. <Event>
  2784. <Id>32806</Id>
  2785. <Message LcId="1033">SAFEIN:Setup Hardware Fault: Diagnosis active Channel. ReturnData:0x{0,x}, ReturnState:0x{1,x}</Message>
  2786. </Event>
  2787. <Event>
  2788. <Id>32809</Id>
  2789. <Message LcId="1033">SAFEIN:Setup Hardware Fault: Feedback Diagnosis active Channel. ReturnData:0x{0,x}, ReturnState:0x{1,x}</Message>
  2790. </Event>
  2791. <Event>
  2792. <Id>32832</Id>
  2793. <Message LcId="1033">SAFEIN:Diagnosis Test: Common Fault Module:0x{0,x} / DiagChannel:0x{1,x}</Message>
  2794. </Event>
  2795. <Event>
  2796. <Id>32833</Id>
  2797. <Message LcId="1033">SAFEIN:Diagnosis Test: Unknown State local ModuleState:0x{0,x}</Message>
  2798. </Event>
  2799. <Event>
  2800. <Id>32834</Id>
  2801. <Message LcId="1033">SAFEIN:Diagnosis Test: Unknown State Other ModuleState:0x{0,x}</Message>
  2802. </Event>
  2803. <Event>
  2804. <Id>32835</Id>
  2805. <Message LcId="1033">SAFEIN Pulse Detection: Wrong pulse was detected at . Module:0x{0,x} / DiagChannel:0x{1,x}</Message>
  2806. </Event>
  2807. <Event>
  2808. <Id>32836</Id>
  2809. <Message LcId="1033">SAFEIN Pulse Detection: Detected pulse from Module:0x{0,x} / DiagChannel:0x{1,x}</Message>
  2810. </Event>
  2811. <Event>
  2812. <Id>32850</Id>
  2813. <Message LcId="1033">SAFEIN:Diagnosis Test: Feedback in Step1 active Channel is wrong. Module:0x{0,x} / DiagChannel:0x{1,x}</Message>
  2814. </Event>
  2815. <Event>
  2816. <Id>32866</Id>
  2817. <Message LcId="1033">SAFEIN:Diagnosis Test: Feedback in Step2 active Channel is wrong. Module:0x{0,x} / DiagChannel:0x{1,x}</Message>
  2818. </Event>
  2819. <Event>
  2820. <Id>32896</Id>
  2821. <Message LcId="1033">SAFEIN:Diagnosis Test:VendorData. ID: 0x{0,x} Module:0x{1,x}</Message>
  2822. </Event>
  2823. <Event>
  2824. <Id>32897</Id>
  2825. <Message LcId="1033">SAFEIN:Diagnosis Test:VendorData. ID: 0x{0,x} Module:0x{1,x}</Message>
  2826. </Event>
  2827. <Event>
  2828. <Id>32900</Id>
  2829. <Message LcId="1033">SAFEIN:Diagnosis Test:VendorData. Channel: 0x{0,x} Module:0x{1,x}</Message>
  2830. </Event>
  2831. <Event>
  2832. <Id>32901</Id>
  2833. <Message LcId="1033">SAFEIN:Diagnosis Test:VendorData. Channel: 0x{0,x} Module:0x{1,x}</Message>
  2834. </Event>
  2835. <Event>
  2836. <Id>32902</Id>
  2837. <Message LcId="1033">SAFEIN:Diagnosis Test:VendorData. Channel: 0x{0,x} Module:0x{1,x}</Message>
  2838. </Event>
  2839. <Event>
  2840. <Id>32918</Id>
  2841. <Message LcId="1033">SAFEIN:DiagnosisTest ViolationCounter incremented, Inputs active (Step1 - check current state). Module:0x{0,x}, Channel:0x{1,x}, Info:0x{2,x}.</Message>
  2842. </Event>
  2843. <Event>
  2844. <Id>32922</Id>
  2845. <Message LcId="1033">SAFEIN:DiagnosisTest ViolationCounter incremented, Inputs active (Step2 - check test pulse). Module:0x{0,x}, Channel:0x{1,x}, Info:0x{2,x}.</Message>
  2846. </Event>
  2847. <Event>
  2848. <Id>32928</Id>
  2849. <Message LcId="1033">SAFEIN:Sercom Fault 0. Cmd/State:0x{0,x}</Message>
  2850. </Event>
  2851. <Event>
  2852. <Id>32929</Id>
  2853. <Message LcId="1033">SAFEIN:Sercom Fault 1. Cmd/State:0x{0,x}</Message>
  2854. </Event>
  2855. <Event>
  2856. <Id>32944</Id>
  2857. <Message LcId="1033">SAFEIN:Unknown Sercom Command Request 1. Cmd/State:0x{0,x}</Message>
  2858. </Event>
  2859. <Event>
  2860. <Id>32945</Id>
  2861. <Message LcId="1033">SAFEIN:Unknown Sercom Command Answer 1. Cmd/State:0x{0,x}</Message>
  2862. </Event>
  2863. <Event>
  2864. <Id>32946</Id>
  2865. <Message LcId="1033">SAFEIN:Unknown Sercom Command Request 2. Cmd/State:0x{0,x}</Message>
  2866. </Event>
  2867. <Event>
  2868. <Id>32947</Id>
  2869. <Message LcId="1033">SAFEIN:Unknown Sercom Command Answer 2. Cmd/State:0x{0,x}</Message>
  2870. </Event>
  2871. <Event>
  2872. <Id>32960</Id>
  2873. <Message LcId="1033">SAFEIN:Error Acknowledge is not possible. Module:0x{0,x}</Message>
  2874. </Event>
  2875. <Event>
  2876. <Id>32961</Id>
  2877. <Message LcId="1033">SAFEIN:Diagnosis Test: Implausible Inputs detected. Module:0x{0,x}</Message>
  2878. </Event>
  2879. <Event>
  2880. <Id>32962</Id>
  2881. <Message LcId="1033">SAFEIN:Diagnosis Test: Implausible Inputs detected (INFO). Parameter1:0x{0,x} / Parameter2:0x{1,x}</Message>
  2882. </Event>
  2883. <Event>
  2884. <Id>32992</Id>
  2885. <Message LcId="1033">SAFEIN:Init HAL Fault.ReturnState:0x{0,x}</Message>
  2886. </Event>
  2887. <Event>
  2888. <Id>32993</Id>
  2889. <Message LcId="1033">SAFEIN:Init Fault. Module:0x{0,x}</Message>
  2890. </Event>
  2891. <Event>
  2892. <Id>33008</Id>
  2893. <Message LcId="1033">SAFEIN: Testpulse is parametrized but not enabled (Diag Testpulse for Inputs active). Module:0x{0,x} / Channel:0x{1,x}</Message>
  2894. </Event>
  2895. <Event>
  2896. <Id>33009</Id>
  2897. <Message LcId="1033">SAFEIN: Testpulse is parametrized but not enabled (Diag TestPulse active). Module:0x{0,x} / Channel:0x{1,x}</Message>
  2898. </Event>
  2899. <Event>
  2900. <Id>33010</Id>
  2901. <Message LcId="1033">SAFEIN: Testfilter-Time too long. Parameter1:0x{0,x} / Parameter2:0x{1,x}</Message>
  2902. </Event>
  2903. <Event>
  2904. <Id>33011</Id>
  2905. <Message LcId="1033">SAFEIN: Inputfilter-Time too short. Parameter1:0x{0,x} / Parameter2:0x{1,x}</Message>
  2906. </Event>
  2907. <Event>
  2908. <Id>33012</Id>
  2909. <Message LcId="1033">SAFEIN: Wrong parameters detected for Module:0x{0,x} / Channel:0x{1,x}. Please check parameters!</Message>
  2910. </Event>
  2911. <Property>
  2912. <Name>DisplayTxtId</Name>
  2913. <Value>true</Value>
  2914. </Property>
  2915. </Source>