修改VAC2 逻辑,长时点亮

bianym 3 månader sedan
förälder
incheckning
f817a1dfe5

BIN
TIN001/TIN001/.vs/TIN001/v15/.suo


Filskillnaden har hållts tillbaka eftersom den är för stor
+ 2 - 2
TIN001/TIN001/PLC/PLC.tmc


+ 1 - 1
TIN001/TIN001/PLC/POUs/_200_Interlock/Interlock.TcPOU

@@ -24615,7 +24615,7 @@ bFFUAlarm :=
                                 <v n="SymbolComment">""</v>
                                 <v n="Address">"Constant_Address_Serialization_Value"</v>
                                 <o n="Flags" t="Flags">
-                                  <v n="Flags">1</v>
+                                  <v n="Flags">0</v>
                                   <v n="Fixed">true</v>
                                   <v n="Extensible">false</v>
                                 </o>

+ 7 - 7
TIN001/TIN001/TIN001/PMC/POU/IO_EXCHANGE.TcPOU

@@ -2905,13 +2905,13 @@ PWQ.	Q100_13	:=	NDO.		;
 PWQ.	Q100_14	:=	NDO.		;
 PWQ.	Q100_15	:=	NDO.		;*)
 
-PWQ.	Q101_00	:=	TRUE (*NOT NDO.	Furnace_1_zone_heating_enable*)	;
-PWQ.	Q101_01	:=	TRUE (*NOT NDO.	Furnace_2_zone_heating_enable*)	;
-PWQ.	Q101_02	:=	TRUE (*NOT NDO.	Furnace_3_zone_heating_enable*)	;
-PWQ.	Q101_03	:=	TRUE (*NOT NDO.	Furnace_4_zone_heating_enable*)	;
-PWQ.	Q101_04	:=	TRUE (*NOT NDO.	Furnace_5_zone_heating_enable*)	;
-PWQ.	Q101_05	:=	TRUE (*NOT NDO.	Furnace_6_zone_heating_enable*)	;
-PWQ.	Q101_06	:=	TRUE (*NOT NDO.	Furnace_7_zone_heating_enable*)	;
+PWQ.	Q101_00	:=	FALSE (*NOT NDO.	Furnace_1_zone_heating_enable*)	;
+PWQ.	Q101_01	:=	FALSE (*NOT NDO.	Furnace_2_zone_heating_enable*)	;
+PWQ.	Q101_02	:=	FALSE (*NOT NDO.	Furnace_3_zone_heating_enable*)	;
+PWQ.	Q101_03	:=	FALSE (*NOT NDO.	Furnace_4_zone_heating_enable*)	;
+PWQ.	Q101_04	:=	FALSE (*NOT NDO.	Furnace_5_zone_heating_enable*)	;
+PWQ.	Q101_05	:=	FALSE (*NOT NDO.	Furnace_6_zone_heating_enable*)	;
+PWQ.	Q101_06	:=	FALSE (*NOT NDO.	Furnace_7_zone_heating_enable*)	;
 PWQ.	Q101_07	:=	NDO.	LDS1_REQUEST_Or_VALVE_OPEN	;
 (*PWQ.	Q101_08	:=	NDO.		;*)
 PWQ.	Q101_09	:=	NDO.	HPM_valve_out_status	;

+ 1 - 1
TIN001/TIN001/TIN001_PLC.tsproj

@@ -329,7 +329,7 @@
 		</System>
 		<Plc>
 			<Project GUID="{DFAAB7BD-C0F0-4652-BE02-16AF7158E2F9}" Name="PLC" PrjFilePath="PLC\PLC.plcproj" TmcFilePath="PLC\PLC.tmc" ReloadTmc="true" AmsPort="851" FileArchiveSettings="#x000e" SymbolicMapping="true">
-				<Instance Id="#x08502000" TcSmClass="TComPlcObjDef" KeepUnrestoredLinks="2" TmcPath="PLC\PLC.tmc" TmcHash="{865CD9AD-25D6-6962-A5E0-ECB0E9453879}">
+				<Instance Id="#x08502000" TcSmClass="TComPlcObjDef" KeepUnrestoredLinks="2" TmcPath="PLC\PLC.tmc" TmcHash="{40686855-5ADB-C3E3-815F-42734B29C375}">
 					<Name>PLC Instance</Name>
 					<CLSID ClassFactory="TcPlc30">{08500001-0000-0000-F000-000000000064}</CLSID>
 					<Vars VarGrpType="1">

+ 1 - 1
TIN001/TIN001/TIN001_PLC.tsproj.bak

@@ -329,7 +329,7 @@
 		</System>
 		<Plc>
 			<Project GUID="{DFAAB7BD-C0F0-4652-BE02-16AF7158E2F9}" Name="PLC" PrjFilePath="PLC\PLC.plcproj" TmcFilePath="PLC\PLC.tmc" ReloadTmc="true" AmsPort="851" FileArchiveSettings="#x000e" SymbolicMapping="true">
-				<Instance Id="#x08502000" TcSmClass="TComPlcObjDef" KeepUnrestoredLinks="2" TmcPath="PLC\PLC.tmc" TmcHash="{067FE6A4-4163-78A4-31BA-2CE0CC4A5717}">
+				<Instance Id="#x08502000" TcSmClass="TComPlcObjDef" KeepUnrestoredLinks="2" TmcPath="PLC\PLC.tmc" TmcHash="{865CD9AD-25D6-6962-A5E0-ECB0E9453879}">
 					<Name>PLC Instance</Name>
 					<CLSID ClassFactory="TcPlc30">{08500001-0000-0000-F000-000000000064}</CLSID>
 					<Vars VarGrpType="1">

BIN
TIN001/TIN001/_Boot/CurrentConfig/PLC.tpzip


BIN
TIN001/TIN001/_Boot/TwinCAT RT (x86)/Plc/Port_851.app


+ 1 - 1
TIN001/TIN001/_Boot/TwinCAT RT (x86)/Plc/Port_851.cid

@@ -1 +1 @@
->Ú¡mø<D	:«ÛÞL#
+²¨I«e—”â�½¶àL⫾

BIN
TIN001/TIN001/_Boot/TwinCAT RT (x86)/Plc/Port_851.crc


BIN
TIN001/TIN001/_Boot/TwinCAT RT (x86)/Plc/Port_851_boot.tizip